Laserfiche WebLink
1 2 3 _ 4 5 6 7 8 9 10 1 11 12 13 14 15 16 <br /> BUILDING CODE REQUIREMENTS -`.Janxo <br /> A A <br /> I I 1180th Street SW <br /> GENERAL REQUIREMENTS BUILDING CODE ANALYSIS EVERETT, WA 98203 <br /> PROJECT JAMC084 BUILDING <br /> LOCATION 1111 80th Street SW WE GRCLF CLASSIFICATI 300.0 PORTABLE FIRE EXTINGUISHERS 906 PLUMBING FIXTURES 29M3 <br /> B PROJECT NO. .2017-04 USE GROUP AREA 906.1 WHERE REQUIRED.PORTABLE FIRE EXTINGUISHERS SHALL BE REFER TO OCCUPANT LOAD TABLE FOR BASIS OF OCCUPANT LOAD AND THUS B <br /> JURISDICTION Everett,WA F FACTORY-MEZZANINE 2,5365E INSTALLED IN THE FOLLOWING LOCATIONS. PLUMBING FIXTURE REQUIREMENTS. <br /> BUILDING CODE 2018 IBC S STORAGE 9,712 SF 1.IN GROUP A,B,E,F,H,I,M,R-1,R-2,R4 AND S OCCUPANCIES. B <br /> B OFFICE 2,536 SF EXCEPTION:IN GROUP A,B AND E OCCUPANCIES EQUIPPED THROUGHOUT 50 OCCUPANTS (25 PER GENDER) <br /> HANDICAP ACCESS ICCA117.1-2009 WITH QUICK RESPONSE SPRINKLERS,PORTABLE FIRE EXTINGUISHERS MALE • <br /> TOTAL TENANT AREA 16,234 SOFT SHALL BE REQUIRED ONLY IN LOCATIONS SPECIFIED IN ITEMS 2 THROUGH 6. WATER CLOSETS REQUIRED 2 <br /> PROVIDED 2 <br /> 2.WITHIN 30 FEET OF COMMERCIAL COOKING EQUIPMENT. 603 Stewart Street <br /> PROJECT TYPE TENANT IMPROVEMENT LAVATORIES REQUIRED 1 suite 610 <br /> C 3.IN AREAS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE STORED PROVIDED 1 C seattle,washington 98101 <br /> BUILDING TOTAL 14,784 SF USED OR DISPENSED. <br /> FEMALE 206.466.5239 p <br /> 4.ON EACH FLOOR OF STRUCTURES UNDER CONSTRUCTION,EXCEPT GROUP WATER CLOSETS REQUIRED 2 206.713.4076 m <br /> R-3 OCCUPANCIES,IN ACCORDANCE WITH SECTION 1415.1 OF THE FIRE PROVIDED 2 <br /> MEZZANINES 505.0 CODE. ksmith@smithco.org <br /> 5 <br /> GENERAL NOTES LAVATORIES REQUIRED 1 <br /> .WHERE REQUIRED BY THE FIRE CODE SECTIONS INDICATED IN TABLE PROVIDED 1 http://www.smithco.org/ <br /> 505.2.1 AREA LIMITATION.THE AGGREGATE AREA OF A MEZZANINE OR 906.1. <br /> 1.VERIFY ALL FIELD CONDITIONS AND NOTIFY ARCHITECT OF ANY MEZZANINES WITHIN A ROOM SHALL BE NOT GREATER THAN ONE- DRINKING FOUNTAIN REQUIRED 1 Consultant <br /> DISCREPANCIES BEFORE PROCEEDING WITH WORK. THIRD OF THE FLOOR AREA OF THAT ROOM OR SPACE IN WHICH THEY 6.SPECIAL HAZARD AREAS,INCLUDING BUT NOT LIMITED TO PROVIDED <br /> ARE LOCATED.THE ENCLOSED PORTION OF A ROOM SHALL NOT BE LABORATORIES,COMPUTER ROOMS AND GENERATOR ROOMS,WHERE p <br /> - 2.ALL WORK SHALL CONFORM TO THE REQUIREMENT OF MUNICIPAL,LOCAL OR INCLUDED IN A DETERMINATION OF THE FLOOR AREA OF THE ROOM REQUIRED BY THE BUILDING OFFICIAL. <br /> FEDERAL AND STATE LAWS,AS ANY OTHER GOVERNING AGENCIES HAVING IN WHICH THE MEZZANINE IS LOCATED.IN DETERMINING <br /> JURISDICTION WHETHER OR NOT SPECIFIED ON THE DRAWINGS. THE ALLOWABLE MEZZANINE AREA,THE AREA OF THE MEZZANINE FIRE ALARM AND DETECTION SYSTEMS 907 SERVICE SINKS REQUIRED 1 <br /> SHALL NOT BE INCLUDED IN THE FLOOR AREA OF THE ROOM. PROVIDED 1 <br /> 3.MAINTAIN ACURRENT AND COMPLETE SET OF CONTRACT DOCUMENTS AT THE <br /> JOB SITE. WHERE A ROOM CONTAINS BOTH A MEZZANINE AND AN EQUIPMENT <br /> PLATFORM,THE AGGREGATE AREA OF THE TWO RAISED FLOOR <br /> 4.MAINTAIN A TELEPHONE WITH WORKING PHONE LINES THROUGHOUT THE LEVELS SHALL BE NOT GREATER THAN TWO-THIRDS OF THE FLOOR EGRESS VVID 1005.0 <br /> PROGRESS OF THE WORK. AREA OF THAT ROOM OR SPACE IN WHICH THEY ARE LOCATED. <br /> E 5.DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION. - REQUIRED: E <br /> EXISTING MEZZANINE 2,536 SF 0.21NCHESX39 OCCUPANTS=152 I1.1CHESTOTAL REQUIRED Consultant Registration <br /> 6.ERECT AND MAINTAIN,AS REQUIRED BY EXISTING FIELD CONDITIONS 536 SF <br /> THROUGHOUT THE ENTIRE PROGRESS OF THE WORK,ALL SAFEGUARDS AND TOTAL MEZZANINE 2, PROVIDED: <br /> BARRICADES FOR SAFETY INCLUDING POSTING WARNING SIGNS,ENFORCING 2.WITHIN 30 FEET OF COMMERCIAL COOKING EQUIPMENT. <br /> SAFETY REGULATIONS AND PROTECTION OF PROPERTY. EXISTING TOTAL BUILDING 12,248 SF/3=4,082 SF<2,536 SF DOOR 1 DOOR 2 WINCHES <br /> INCHES <br /> 7.ALL CONCEALED WOOD TO BE FIRE TREATED. 3.IN AREAS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE STORED <br /> USED OR DISPENSED, 72 INCHES PROVIDED <br /> B.CHECK ALL CEILING HEIGHTS AND POSSIBLE CEILING PLENUM CONDITIONS FOR 4.ON EACH FLOOR OF STRUCTURES UNDER CONSTRUCTION,EXCEPT GROUP <br /> F CLEARANCE OF DUCT-WORK AND ALL OTHER CONSTRAINTS TO ASSURE THE R-3 OCCUPANCIES,IN ACCORDANCE WITH SECTION 1415.1 OF THE FIRE EXIT ACCESS TRAVEL DISTANCE- 1016.0 F <br /> LOCATION OF THE LIGHT FIN TIRES AS SHOWN ON THE LIGHTING PLAN.ANY COOS. <br /> DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN AUTOMATIC FIRE SUPPRESSION SYSTEM PROVIDED <br /> WRITING BEFORE PROCEEDING WITH THE WORK. 5.WHERE REQUIRED BY THE FIRE CODE SECTIONS INDICATED IN TABLE <br /> 906.1. ALLOWABLE LENGTH OF EXIT <br /> 9.PRIOR TO CLOSING OF ANY CEILING,ALL MECHANICAL SYSTEMS(I.E.HN.A.C., ACCESS TRAVEL PER USE. REQUIRED PROVIDED Architect Registration <br /> PLUMBING,AND ELECTRIC)SHALL BE INSPECTED AND WHERE REQUIRED,TESTED CONSTRUCTION CLASSIFICATION- 601.0 6.SPECIAL HAZARD AREAS,INCLUDING BUT NOT LIMITED TO <br /> BY THE LOCAL AUTHORITIES HAVING JURISDICTION TO INSURE THEIR PROPER LABORATORIES,COMPUTER ROOMS AND GENERATOR ROOMS,WHERE OCCUPANCY: B 200 FT <200 FT <br /> INSTALLATION AND FUNCTION. <br /> TYPECIIB CONSTRUCTION REQUIRED BY THE BUILDING OFFICIAL. <br /> 10.CEILING HEIGHTS ARE DIMENSIONED IN RELATIONSHIP TO THE FINISHED FLOOR 6294 <br /> G AND/OR DECK. G REGISTER] <br /> 11.LIGHT FIXTURES SHOWN IN ACOUSTICAL TILE CEILINGS SHALL BE LOCATED IN AUTOMATIC SPRINKLER SYSTEMS 903.0 OCCUPANCY L I004-U INII=RIOT EXIT STAIRWAYS 10222 <br /> THE CENTER OF THE NEAREST LOCATED FILE,UNLESS OTHERWISE NOTED IN PLANS. <br /> USE AREA SF OCCUPANTS K�WASHI <br /> 12.INSTALL ALL LIGHT FIXTURES UNLESS OTHERWISE NOTED. 903.2.1.2 GROUP Fi.AN AUTOMATIC SPRINKLER SYSTEM IS INTERIOR EXIT STAIRWAYS AND INTERIOR EXIT RAMPS SHALL BE ENCLOSED <br /> REQUIRED FOR GROUP F1 OCCUPANCIES; PER WITH FIRE BARRIERS CONSTRUCTED IN ACCORDANCE WITH SECTION 706 OR STA <br /> PERSON HORIZONTAL ASSEMBLIES CONSTRUCTED IN ACCORDANCE WITH SECTION <br /> 13.ALL ELECTRICAL WORK SHALL BE COORDINATED WITH WORK, FIRST FLOOR 711,OR BOTH.EXIT ENCLOSURES SHALL HAVE A FIRE RESISTANCE RATING <br /> PLUMBING,WOODWORK,PARTITION WORK ETC.,WHERE REQUIRED. <br /> . 1.AUTOMATIC FIRE SPRINKLERS EXISTING <br /> F FACTORY-MEZZANINE 2,536 SF 500 5.07 OF NOT LESS THAN 2 HOURS WHERE CONNECTING FOUR STORIES OR MORE <br /> 14.COORDINATE ALL TELEPHONE WORK AND IT WORK WITH OWNER'S AND NOT LESS THAN 1 HOUR WHERE CONNECTING LESS THAN 4 STORIES. <br /> H REPRESENTATIVE AND LOCAL TELEPHONE COMPANY BEFORE STARTING WORK. S STORAGE 9,712 SF 500 19.42 1 STORIES<4 STORIES=NOT REQUIRED H <br /> Issues and Revisions <br /> 15.ALL STRUCTURAL CONTENT SHOWN IN ARCHITECTURAL DRAWINGS IS FOR AUTOMATIC FIRE SPRINKLERS EXISTING 8OFFICE 2,536 SF 100 25.36 <br /> No. Date Issues <br /> DESIGN INTENT REFERENCE ONLY.REFER TO STRUCTURAL DRAWINGS. <br /> 092 1 0426.21 PERMIT <br /> SYMBOL LEGEND TOTAL BUILDING OCCUPANCY 49.85-50 <br /> ROOM NUMBER ID ROOM NAME EXTERIOR I <br /> SEE SHEET 6.05 FOR ELEVATION MARKER 5.01 <br />-- ROOM FINISH SCHED. <br /> DOOR NUMBER ID C100 BUILDING A <br /> SEE SHEET A6.01 FOR SECTION MARKER 5.01 <br /> DOOR SCHED. <br /> VIEW WINDOW ID Q <br /> SEE SHEETA6.02 FOR <br /> WINDOW FRAME TYPES. WALL t <br /> SECTION MARKER <br /> CODED NOTE ID Oi Project Name Aero jet Rocketclyne <br /> A <br /> n Project Number 02016063.01 <br /> WALL TAG INDICATOR 7 INTERIOR 601 Description CODE NOTES <br /> ELEVATION MARKER <br /> 1( TYPICAL DETAIL <br /> K Computer File T-102.DWG <br /> DESIGNATION <br /> DETAIL NUMBEfl DETAIL NUMBER�A <br /> Scale AS NOTED <br /> A <br /> 5.01 <br /> SHEET WHERE DETAIL SHEET WHERE DETAIL 6.01 Template <br /> IS SHOWN IS SHOWN All ideas,designs,arrangements,a and plans indicated <br /> r represented by this tlrewing are awnetl by and the <br /> property of smith co.lc and were mated,evolved,and <br /> developed for use on and in connection with the <br /> specified project.None of such ideas,designs, <br /> L I arrangements or plans shall be used by or disclosed to <br /> L any person,fine,or corporation for any purpose <br /> whatsoever without the written pennission of smith co. <br /> 2 T- 102 <br /> 3 4 5 6 7 8 9 10 11 12 13 14 15 16 <br />