Laserfiche WebLink
SLIDING GLASS DOOR <br /> SELF ADWE51VE (' i'- PER PLAN <br /> MEMBRANE PAN --SLIDING GLASS DOOR EXTEND MIN.6'UP JAMB <br /> FLASHING / NAIL FLANGE 1 <br /> NAIL ON FLEXIBLE -GALV Z'FLASHING NERVA5TRAL TO EXTEND ,. / <br /> 2'PAST THE INTERIOR <br /> FLASHING--. 2"MIN FROM TOP OF \ HEADER/ i, \ HEADER/ <br /> \ / LEDGER TO LAG SCREW \ OF THE DOOR <br /> FLOOR JOIST \, /� STUD- - - <br /> PER PLAN—. 5/4x4 CEDAR DECKING J ROUGH ROUGH <br /> -.....-. _ ... J <br /> 2x PT JOIST PER PLAN BARRIER - ` \ A/£E JAMB\ JAMB\ <br /> PER PLAN WATER-RE°I-FIVE OPENING OPENING I <br /> 14ANGER PER PLAN JOINT FLASHING 1 -` 2ND C / SILL \ / SILL \ <br /> INSTALL FLANKS "&.D <br /> N MODERATE PENETRATION <br /> RIM JOIST SIDING PER PIECE ;'.. SILLPT LEDGEk PER P'_,FN CONTACT - �BUILDING PAPER SHEATHING PER PLAN --INSTALLED BEHIND /�— FLASHING <br /> LEDGER AND PAN �51DING PER PLAN PLAN --- <br /> FLASHING LAP BUILDING PAPER TO EXTENDATTACH SILL STRIP OF 9'WIDE MOISTOP OR E0, FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9"WIDE MOISTOP OR EOOVER HDUSE WP,AP -_- +LEDGER INSTALLED BEfOkE 51C:NG _ MIN.12'BEYOND ALL EDGES STEP I STEP 2 (�w/BUILDING PAPER BEHIND'iT w/8" OND `y OF THE PENETRATION ( ) ( .). {---L WITH THE TOP EWE EVEN WITH THE TOP OF THE ROUGH 51LL. FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB Lu <br /> EXPOSED ON ALL 4 SIDES •EXTEND THI5 STRIP AT LEAST 12'BEYOND THE EWE OF THE ROUGH OF THE ROUGH OPENING. — <br /> OPENING. •START JAMB STRIPS 2'BELOW SILL STRIP AND EXTEND 0 <br /> DECK LEDGER DETAIL SIDING BUTT Ol,4 FLASHING EXTERIOR DOOR FLASHING PENETRATION PROTECTION ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLES. ABOVE LOWER EWE OF HEADER. ( 1� <br /> W22 SCALE:N.T.5. W15 SCALE:N.T.S. WI4 SCALE:N.T.S. CID <br /> N.T.S. <br /> mReR_F I urolNb a �:... CONT.BEAD OF O <br /> HEAD _..—SEALANT <br /> E0. EO. FLASHING UNDER NAIL FIN ( � <br /> 2' 2' �.J <br /> w D PER PUN 5G <br /> OPERPBLE FIXED ■ <br /> t_P PANEL LUT AWAY <br /> WINDOW EXCESS WINDOW n/ <br /> LINE OF FRAME OR BLDG.PAPER FRAME OR lJ= <br /> LL- <br /> ______ <br /> .-' NERVESTRAL -- ----------I ILL HFARTYMOD CEDAR TRIM, I <br /> BDIIND I T J I EQ.ALL SIDES,CAULK/5EAL SIMILAR @ OPENING SIMILAR LU <br /> V-b TO HOSE BIB Bohan E0. bl �' E0. OPENING OPENING f <br /> 3'6 TD SIDING I �lll ' 3'0.u"Dw`TYP. {NOTE: SEAL ALL BUILDING v <br /> POUR AGAINST <br /> L L OF I "I NERVAS RA EXPOSED FASTENERS BUILDING PAPER <br /> PRONTO I FRONT PORCu PATIO - PAPER TYP. -! <br /> SHEATHING PER PLAN <br /> BEND ELECTRICAL 3'-6'LANDING TYP. ya PATe• " Ts LINE OF BUILDING PAPER TYP. j <br /> METER MAIN O. BACK PATIO's se Fa�xrn N"E°R�1P1 INSULATION BLW PAPER - NAIL FLANGE UNDER SILL STRIP' <br /> a TIH ram sloe a-Z <br /> sc.o.nmuvm rossl� PER PLAN _._ _.... <br /> ® PRONTO BEND APPROVED FLASHING <br /> FRONT INSTALLED ON DOOR -'H- x+b NEARTYKVD CEDAR TRIM (0.19 x 10'ROLL) STEP 3 STEP 4 <br /> CORNER LANDIN.PER PLAN.PDUR •APPLY A 3/8°CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME •APPLY THE NEXT COURSE OF BUILDING PAPER(BUTTING TO THE O <br /> OF HOUSE / QML OF 4OU5E THRESHOLD AGAINST NERVE5TRAL 2+6 NEARTNwD CEDAR 51DING PER PLAN 1-1/2'GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING)OVER THE JAMB FLASHING MATERIAL. <br /> 304 FELT PAPER--- -- ------------ TRIM'w FLASHING r BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE .-r\ <br /> AT GARAGE BHOSEIBB WAVESTgAL I HOUSE INTER5ECTION, co <br /> ��-BIBH -LANDING PER PLAN WERE aclRs INSTALLED JAMB AND SILL t JAMB MOISTOP(OR E0.)FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF 1 , <br /> INSTALL STARTER STRIP K„ '" (MIN va,TYP) I ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH. 11- <br /> -=OF STEPS TBD BY LINE a NERVESTRu •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER <br /> GROUNDING \ ruD SILL SITE CONDITIONS �30n FELT TO EXTEND UP THE SILL STRIP AND CUT ANY EXCE55 BUILDING PAPER THAT MAY EXTEND <br /> `-PROD 12'RONTO BEND 1 I - WALL 12"MIN. <br /> FLASHING- <br /> - - ---------- III SLAB ON.BADE ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING. <br /> GUTTER PER I wALI •ADD FORTIFLASH STICK FLASHING @ BOTH SIDES OF WINDOW >' <br /> FGRTIFLASH o/FLASHING ,- q„MOIST)P PLAN-- ROOF TRUSS _ _ � - •APPLY SLOPED 28 GA..2"BACK,PREFIN15HED METAL FLASHING TO OPENING. <br /> AND MOISTOP.TURN ROOF SHEATHING PER PLAN •APPLY b'FORTIFLASH OVER TOP HEAD FLANGE of WINDOW.EXTEND PAST 1-1--1 <br /> FORTIFLASH I"ONTO PANEL, FASCIA PER PLAN- EXT. LANDING DETAIL @ ROOF TRU55 JAMB FLASHING 2°. <br /> ALL 51DE5{CORNERS. <br /> FLASHING �LtiSNIN ut EAVE , ROOF TO WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS <br /> 2x2 TRIM @ PERIMETER TYP,' - SLIDING GLASS DOOR TYP Q <br /> W13 - - W12 WII WIC <br /> OPENING FOR ELEC. 50 MIN.dLDG SCALE N T.5. SCALE:N.T.S. SCALE:N.T.5. SCALE:N.T.S. <br /> DIETER BOX,FIREPLACE PAPER BEHIND <br /> DIRECT VENT,RANGE VENT, METER MAIN <br /> DRYER VENT,ETC, SEAT WINDOW FRAME <br /> N5ULAI ION --7/16'PLYWD.SHEATHING y e Y Ef�� <br /> +SEE DETAIL WIO FOR M015TOP INSTALL INSTRUCTIONS SILL A55EMBLY 3/S"BEAD CAULK (WHERE OCCURS) 6°FORTIFLA5H 0/FLASHING l--L--p1 �\ <br /> ,} PER SPEC— ,�SEALANT <br /> M _E <br /> ELECTRIC METER W HOSE BIB TRIM PER ELEVATION GYP.BD. WD.FRAME WALL 51DING PER PLAN <br /> — <br /> LVI (WHERE APPLICABLE) INSULATION PER PLAN --BUILDING PAPER <br /> LOCATION (NO GAS METER) (WHERE OCCURS) MOISTOP(SEE DETAIL WHOVV7 TRIMMER R-10 INSULATION <br /> SCALE:N.T.S. MDISTOP(SEE DETAIL BEHIND HDR,TYP 0 FOR INSTALL) <br /> GYP.BD. WIO FOR INSTALL) KING STUD IND,FRAME WALL ALL HOR's MIN.I/4"GAP BTWN SIDING <br /> _- <br /> SEALANT PER PLAN GYP.BD. AND FLASHING <br /> OV L;;._. 11N.IS' EXT WALL PER FORTIFLASH ON ALL MOISTOP(SEE - COPYRIGHT Norlce�Tuls <br /> PLAN SIDES OF WINDOW , HEADER PER PLAN FLASHING TURN DOWN % PLAN 15 OPINED BY PACIFIC <br /> DETAIL Will <br /> ..>-, - RIDGE HOMES.USE a Tu15 <br /> ---- SIDING PER PLAN FOR INSTALL) 7/16 PLYWD.SHEATHING I/A"AT EACH END PVN I5 PR 81TO BY IM <br /> INSULATION WINDOW FRAME TRIM PER ELEVATION LICEN5E FEE TO PACIFIC <br /> WITHOUT PAYMENT a <br /> c1.1: 'ER TYP. (WHERE OCCURS) BLDG.PAPER SEALANT BLDG..PAPER 5EE ELEV FOR (WH APPLICABLE) RIDGE HOMES <br /> SIDING PER PLAN WINDOW HT <br /> _10'-6'TO HOSE BIB <'.r. 2 PLAN I 7/16'PLYWD.SHEATHING TRIM PER ELEVATION SEALANT <br /> 8'-b'TO G.L. _.2N.il'.D TRIM (WHERE APPLICABLE) FORTIFLASH ON ALL SEALANT -..-�� - / PLAN SUMMARY <br /> OF PRONTO BEND SIDES OF WINDOW WINDOW FRAME uHs:nn mxsaenmrr, <br /> WE <br /> GE TO EWE TO 3'-0' W9 SIDING_ / INSIDE '" RNER WS WINDOW SILL @ WOOD FRAME WALL W7 WINDOW JAMB DETAIL WINDOW HEAD DETAIL �"„/A <br /> E -. I.y <br /> EDGE EWE ELECTRICAL SCALE:N.i.S. SCALE:N.T.S. SCALE:N.T.S. SCALE:N.T.S. 806 <br /> METER MAN <br /> — ® PRONTO BEND 1075 <br /> FRONT <br /> INSTALLED ON <br /> CORNER EXT:OF HOUSE LAP SIDING,U.NO.(HOLD 1-1/2 <br /> T1801 m rt <br /> OF HOUSE STUDS @ I6°oc(NO POSTS/ c.PAcs w OFF ADJOINING ROOF) POINT LOADS ABOVE VENTS) <br /> AT GARAGE --i _HDSE JAG SCREW �!, I,�SIDING PER PLAN � <br /> BIBB �I ATTACHED METAL FLASHING E0. E0._ YYY 424 <br /> GAS J ;YIDS.LAG (MAY BE STEPPED) —�` <br /> METER INSTALL + .+ - -- - BOTTOM SILL PLATE ELECTRIC <br /> .FI PENETRATE BUILDING PAPER ON wY ELECTRIC <br /> j GROUNDING /. 3/4'T{G SUBFLOOR "Aorizruui raamn..m <br /> _....._._. _.. .,FUL' i IN.,TYP.@ SHEATHING SIDING CUT <br /> -ROD TO Fk01'I_ ( j i i i FLASHING JWA <br /> PRONTO BEND i/�-: 2/3 HT OF AWAY FOR CLARITY) <br /> FORTIFLASH o/FLASHING 'a''^I - CN w/196' VENTS1w/CALVE DARR <br /> SCREEN- <br /> - DAR RIM <br /> q"f'0>7JP < STRAP MIN METAL RAIN DIVERTER(THE w III / BTL ENGINEERING <br /> AND M015TOP.TURN PROVIDE LOUVERED VENTS <br /> FORTIFLASH I'ONTO PANEL, PURPOSE IS TO SHED THE P FRONT ELEVATIONS nwiR° <br /> A,-L 51DE5{CORNERS OF HWT WATER OFF THE ROOF AND / ROOF SHINGLES <br /> fLASNING KEEP IT AWAY FROM THE PER SPEC. RIM PER PLAN SEE REV15ION LOG <br /> 2r2 TRIM @ PEkIMETtF: - TYP VERTICAL WALL BENEATH). /fw P.T.MUD SILL c�A�y" =p-O" <br /> OPENING FOR ELEC - _ '-60 MUJ.BLGN L 1 OF HWT FASCIA PER PLAN w/ / 30a ROOF FELT CONCRETE FOUNDATION <br /> ��� 7/16"0513 ROOF ++DO NOT INSTALL VENT(5)CLOSER THAN 3'TO GAS METER"+ <br /> METER BOX,FIREPLACE _ PAPER BEHIND SHEATHING ++BUILDING PAPER SHOULD BE INSTALLED OVER FLASHING,,DIRECT VENT,RANGE VENT, '" METER MAIN WATER <br /> DRYER VENT, ETC. / INTRUSION <br /> NOTE:PER WSEC R402.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE TOP DETAILS <br /> "5EE DETAIL WIO FOR M015TOP INSTALL INS(kUCT�DFIc OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> ELECTRIC t GAS METER, NOSE +NOT E: SEAL ALL ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF W'FROM HORIZONTAL,TO <br /> W J I ' USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. <br /> CBIB CLEARANCES 1$ LOCATIONS CATER NEATER (HWT) STRAPS DETAIL @ ROOF/WALL INTERSECTION <br /> 1 W2 � YI /FOUNDATION VENT 1 /1 <br /> SCALE:N.T.S. X:ALE:N.T.S. SCALE:N.T.S. \V� SCALE:N.T.S. I l,� <br />