FLOOR PLAN NOTES
<br /> DOOR t JAMB
<br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,MATERIALS t CONDITIONS PRIOR TO
<br /> CONSTRUCTION. n+r CLCRjPER PLAN CAULK BACK OF
<br /> THRESHOLD TO WRAP NERVA5TRAL
<br /> WINDOWS t DOORS: �_-- .LTERED w-I NERVE5TRAL UP JAMB 6'
<br /> °RONT .5LAB t ALL SEAMS (2)V BEADS OF
<br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/R-10 INSULATION. '--- -
<br /> _ 4'-0' _ CAULK UNDER
<br /> 3. WINDOWS E DOORS ARE SHOWN t NOTED AS NOMINAL SIZES. ELEVaT1pN - "- CAULKHERVIE UND (1)
<br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRE55 WINDOW SILL HEIGHT R.O.@ _��� -------- "
<br /> MAX,42"A.F.F. 2 a PLATE a -- j DOOR THRESHOLD @ SIDES OF JAMB _ -
<br /> kA15ETi WAi L, I� (2)24e TO BE WRAP EDGE t
<br /> 5. ALL WOOD IN CONTACT WITH CONC.TO BE PRESSURE TREATED. RIPPED.O --- ------- RErNVED PRIOR THRESHOLD w/
<br /> b. EXTERIOR WALLS TO BE 2x6 STUDS @ 16"O.C.,U.NO. 3 wa FLLix -TOE KWGc---- STEP K BEING ADD'L NERVASTRAL NERVASTRAL OR EO
<br /> 7. GARAGE DOOR HEADERS @ 84'A P.F. 015 ...-_ �...�_ a DOOR.. PLURED THRESHOLD DETAIL ^ -
<br /> 8. EXTERIOR SWING DOOR HEADERS @ 83 1/2'A.F.F. PER PLAN n 0'q. INTERIOR SWING DOOR HEADERS @ 83'A.F.F. oLDG PAP R r Dq SCALE: 1-1/2'=1'-0'
<br /> EIT10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS END,X15T "-"-' aD
<br /> 4L BE 3"MIN.ON HINGE SIDE. END x CONc.
<br /> H. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD;%'THICK 20-MINUTE FIRE-RATED DOOR PLATE+,'Er 7FRONT
<br /> w/A SELF CLOSING HARDWARE DEVICE. WALL BEYCNO RCH FMRCH °T.O.RAISED
<br /> OPE STEM WALL TO
<br /> 12. PER R311.3.1:THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL PKTERIOR DOORS 97Er1 ,'PER Lw. STEM
<br /> HALL. T.O.FRQ4T PORCH 5'3V2' 6'-0' 4'-IQT 3'-IIY2' V-0" 4'-IC)Y'
<br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4'BELOW THE TOP OF THE SECTION y,All, F.Tux. STEM WALL-7' (2)24"x36"HEAT 1 11----1
<br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR __ p _ PUMP 30 HE L_L_l
<br /> 13. ALL BI-FOLD t BI-PASS DOORS TO BE CENTERED,U.N.O. FRON PORCH EXT. DETAIL WHEN GARAGE W12 7
<br /> r� Q ?i��
<br /> STEP _
<br /> FRAMING: V38 SCALE:I% I'-0' LONG.4. VERIFY FIREPLACE STYLE t LOCATION w/SUPERVISOR PRIOR TO CGNST.
<br /> LANDING
<br /> 16. FRAMERS TO INSTALL ALL WINDOWS!INTERIOR COLUMNS
<br /> Ib. TOWEL RING BLK'G @ 57'A.F.F. 6046 XO
<br /> rEx rxn 4 LrNwxa w 5068 SGD(SG) O
<br /> 17. TOWEL BAR BLK'G @ 48°A.F.F.t BLOCK BOTH BAYS. I -Nr DDaR i axalBlE �-
<br /> 18. TOILET PAPER HOLDER BLK'G @ 22"A.F.F.AND 42"FROM BACK WALL WHEIRE PO551BLE "'"a511p� ACTIVE
<br /> ACTIVE(FOR MINI-S LIT Lu
<br /> I9. THERMOSTAT BLK'G @ 60°A.F.F -. _ EQ. 7':� BATH FAN VENT �J
<br /> 20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE INSTALLED AT 7'-6'A.F.F. 5GD PER PLAN CLEARANCE) NOOK
<br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE 5HALL ALIGN WITH TOP OF THE RASLE FIXED -
<br /> GARAGE DOOR TRIM nNB. PARE. q'6x13'5
<br /> 22. ADD CGNT.BLOCKING FOR STAIR HANDRAIL BRACKETS LINE CF-- _---_ __ __________
<br /> 23. STAIRS w/WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL INSTALLED ON SERVE TR L 1 2x6 HEARTWOOD CEDAR TRIM, 2CM OVERHANGS TO BE 8"t
<br /> I W.ALL SIDES,CAULK/SEAL D25 3CM OVERHANGS TO BE 12" .b
<br /> THE INSIDE OF THE STAIR'S RUNS" Ea. GREAT ROOM -\ -
<br /> 24. LADDER-BLOCK AT EXTERIOR WALLS AS NECESSARY FOR 1N5ULATION IN�Fr,L u;rrrn OF3'0 LANDING IF. 12 13'xI5'q 345.4°Hx q'-q'L 2,4 @24" �
<br /> SIDING - POUR AGAINST ELECTRIC f tT
<br /> VENTILATION: ' NERVASTRAL T., FIREPLACE _ cPr WALL PLACE DRYWALL \_J
<br /> xC4 PATIO° ON SINK E q'-7"
<br /> us
<br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL EXHAUST FAN IN i. ,'LANDING
<br /> ACCORDANCE WITH 1`11505.4.1.1, PATi°' 0""'""
<br /> 0 ''BACK PATIO'S a n+E mxeTxx
<br /> 26. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY. ->- a n+x FmD svE a ruE SD/CO INSTALL KE
<br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE MI505.4.3(I).EXAMPLE:70 CFM FOR 2600 ❑ _ :xb STACKED
<br /> -2xe HEARTWOOD CEDAR TRIM s b'-5° 4'-0' BLKNG FOR
<br /> SF HOME w/4 BEDROOMS,AND THEN INCREASE BY FACTOR OF PER TABLE LANDING PER PLAN POUR I D/W RANGE HIND
<br /> M1505.4.3(2)TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED VENTILATION SYSTEM. -1^ AGAINST NERVESTRAL 2x6 HEARTWOOD CEDAR - I o BOTH SIDES z
<br /> 28. WHOLE HOUSE FAN SHALL BE 1.0 50NE5 OR LESS,AND SHALL NAVE AN EFFICACY OF 2.8 F- - --� TRIn Wx FLASHING e - OF CENTER \
<br /> CFM/WATT PER WSEC R403.6.1. rI R Esiwl - 1 HOUSE MTERMOrm, STUD P+68'
<br /> 29. FRESH AIR 5HALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOWS PER STATE L. _ _ WHERE OCCURS -^ J ',DIN Al
<br /> aDIN'S ITyp uw _ K/S(I GAP, Dw KITCHEN 5 ®I,Q CENTER
<br /> -- )
<br /> 30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE IT m
<br /> LODE INTERPRETATION 17-15. _ � y
<br /> OF55TEP$TBQ BY I LINE OF NERVESTRAL _ - ---- 266a 3 SIDE 10'4XI3'S p I
<br /> LO u- E CONaT1045 ELECTRIC ,, OPT 246a z ® STUD BAY _ LL
<br /> WHOLE HOUSE FAN. IB"x24"CRAWL y 1 Ns P z ON RANGE "�"
<br /> 31. PER IRC MI502 4.5. WHERE THE DRYER VENT EXHAUST DUCT 15 CONCEALED WITHIN THE corn,w+,"+-G-`- sue au GRADE: ACCESS 12x51 0 2068 BF SEE CAB
<br /> m
<br /> BUILDING CONSTRUCTIGN THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE - SEE as Fax'Pvxr aua FIREPLACE OPT. LINE OF M� A
<br /> Q I FOR
<br /> IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG 5HALL BE LOCATED aNDING D HID BrcNT wxw aETNI , FLOCR ABOVE 12° �R LOG
<br /> a,
<br /> WITHIN 6FT OF THE EXHAUST DUCT CONNECTION. SCALE: 1/4'=1'-0' 2'-5 - REFER 39" _____ pp �nn +STAIRS w/WINDER OPN'G LLJ
<br /> � ETAL l KNEE WALL LIFE SAFETY: y BELOW _ STEPS WILL ALWAYS h1- .� GLASS DOOR TIP HAVE A CONTINUOUS qmNWT TO BE 26. A HEAT ALARM OR HEAT DETECTOR RATED FOR ATiBIENT OUTDOOR TEMPERATURES AND ) - - b,
<br /> - HANDRAIL INSTALLEDWH,3INSTALLED IN -1
<br /> HUMIDITY TO BE CENTRALLY LOCATED IN"fHE GARAGE. ' �-', °J ° ON THE 51D OF 5'- ' 3 '-"` R./ THE 3rd CAR v O
<br /> 27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE -
<br /> ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY, ROOM OR " - THE STAIR RUN GARAGE OR
<br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION OPEN TO q"BOLLARD GARAGE
<br /> 5T ABOVE - BUMP-OUT WHEN Z
<br /> 10. SMOKE DETECTORS TO BE IIOV, INTERCONNECTED,w/BATTERY BACKUP e CENTRALLY 2T THAT OPT.IS
<br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE a 6'-11, I'-5" SELECTED.
<br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 -- e - �\
<br /> It. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM THE IT
<br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER.LR314i 15R,14T
<br /> 12, IONIZATION SMOKE ALARMS: UP ARA E
<br /> 4 SHALL NOT BE INSTALLED LE55 THAN 20 FT HORIZONTALLY FROM A PERMANENTLY 5'_7y' 2'_r° 1T3x10'q
<br /> INSTALLED COOKING APPLIANCE. WRAP ALL WARM WALLS, PS,
<br /> + IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING 5WITCH SHALL NOT BE INSTALLED S
<br /> LINE OF BEAMS d SUPPORT WALLS POSTS
<br /> LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. 3'-IV'a' a, FLOOR G.W.B.E 5/8"TYPE"X"ON THE
<br /> 24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LE55 THAN 6 FT ° - ABOVE CEILING "
<br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE M141 D r `�
<br /> 25.GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2'G.w.B.t 5/8" c COPYRIGHT
<br /> PUN 1I OWNED
<br /> NOTICE:
<br /> ICE:BY T415 PACIFIC
<br /> TYPE'X'ON THE CEILING,POLY SEAL RIM,ENTIRE GARAGE TO MEET JURISDICTION g O�. '��i RIDGE HOMES.USE of THIS
<br /> DRAFT STOP REQUIREMENTS flA4
<br /> a DEN - - ----_ PUN IS PROHIBITED BY LAW
<br /> _ WITHgJT PAYMENT OF
<br /> 26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH,�"GWB AT THE z T2X10'3 LICENSE FEE TO PACIFIC
<br /> WALLS,UNDER-STAIR SURFACES AND SOFFITS. DEN '� in RIDGE HOMES.
<br /> 27. PROVIDE FIREBLY-KI14G PER PLAN AND @ ALL PLUMBING PEINETRATIONS. T2XI0' A4 ORPLAN SUMMARY
<br /> UTILITYLAYOUT, N/A
<br /> SEE A10 °wlrenurr,,
<br /> 806
<br /> fRGL I5H b 1 FRON Tm� .wrc
<br /> NTS PORC - 15070 GARAGE DOOR g„ 18BI
<br /> FRONT PORCH
<br /> 72 SF ❑a 41 5 a - - - 424
<br /> ❑ ❑ ELECTRIC
<br /> �
<br /> EP UP v
<br /> JWA
<br /> a
<br /> -EP UP i� BTL ENGINEERING
<br /> 'w
<br /> SEE REVISION LOG
<br /> 2:1 15'-3'R0.
<br /> 1 '-0' SCALE:Y' = I'-0'
<br /> 2'-I0Y 9'-5° 5'-7y' b'-8' 1T-4v, c ano-
<br /> - DRIV WAY WIDTH EXTENDED FRONT PORCr MAIN FLOOR PLAN
<br /> DI ___;_ ILL '/PORCk PLAN
<br /> -- =LACE: 3/8°=11-o' OPTION - 'A' ELEV. MAIN FLOOR PLAN - 'A' ELEV.
<br /> SCALE: 1/4"=1'-0'
<br /> SCALE: I/4"=1'-0" {�\
<br />
|