Laserfiche WebLink
FLOOR PLAN NOTES <br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,MATERIALS t CONDITIONS PRIOR TO <br /> CONSTRUCTION. _.. .. <br /> WINDOWS d DOORS: <br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/R-10 INSULATION, <br /> 3. WINDOWS t DOORS ARE SHOWN t NOTED AS NOMINAL SIZES, <br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R.O. <br /> MAX.42'A.F.F. <br /> 5. ALL WOOD IN CONTACT WITH CONIC.TO BE PRESSURE TREATED. <br /> b. EXTERIOR WALLS TO BE 26 STUDS @ I6"O.C.,LINO. <br /> T GARAGE DOOR HEADERS @ 84'A.F.F. 30'0' I►�._ <br /> 8. EXTERIOR SWING DOOR HEADERS @ 63 1/2'A.F.F. <br /> q. INTERIOR SWING DOOR HEADERS @ 83'A.F.F. <br /> 10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS OR BE 3'MIN.ON HINGE SIDE. <br /> II. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD Ite THICK 20-MINUTE FIRE-RATED DOOR 5y2" - <br /> w/A SELF CLOSING HARDWARE DEVICE. 4'4Y' 6'-0" 4'-7Y4" <br /> 12. PER R311.3.1:THE LANDING OR FLOOR ON THE FXT ERIOR SIDE OF ALL EXTERIOR DOORS �--t <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4"BELOW THE TOP OF THE <br /> THRESHOLD PROVIDED THE DOOR DOES NOT 5WING OVER THE LANDING OR FLOOR <br /> 13, ALL BI-FOLD t BI-PASS DOORS TO BE CENTERED,U.N.O. <br /> FRAMING: (� <br /> 14. VERIFY FIREPLACE STYLE t LOCATION w/SUPERVISOR PRIOR TO CONST. 6046 XO 2030 X <br /> Is, FRAMERS TO INSTALL ALL WINDOWS t INTERIOR COLUMNS (EGRESS) (OBS) O <br /> 16. TOWEL RING BLK'G @ 57'A.F.F. <br /> 17. TOWEL BAR BLK'G @ 46'A.F.F.4 BLOCK BOTH BAYS. W/5(I) 1 \ <br /> 18. TOILET PAPER HOLDER BLK M'G @ 22"A.F.F.AND 42"FR' BACK WALL WHERE P05SIBLe l7 R -------- �J <br /> 10. THERMOSTAT BLKG @ 60'A.F.F -IT <br /> - <br /> 20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE INSTALLED AT 7'-6"A.F.F. DTOI <br /> 60''VANITY <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE <br /> GARAGE DOOR TRIM LL- <br /> 2bb8 BATH 1 `�' _ <br /> 22. ADD CONT.BLOCKING FOR STAIR HANDRAIL BRACKETS crr 77 SF o bq SF ;_, (� <br /> BEDROOM I Q w <br /> 23. STAIRS ID WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL INSTALLED ON i ' _ + NI_7+ `^ 36"x80"GWB <br /> THE INSIDE OF THE STAIR's RUN I3 XI4 4 FINISHED 3 - <br /> 24. LADDER-BLOCK AT EXTERIOR WALLS AS NECESSARY FOR INSULATION INSTALL , � OPENING <br /> TB 2 _ <br /> I <br /> VENTILATION: N <br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED B'f A CENTRAL EXHAUST FAN IN <br /> ACCORDANCE WITH M1505.4.1.1. 4'SZ" 5BID <br /> D W 5(I) <br /> 26, WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY. (TO FACE OF RISER) SO _ <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(1).EXAMPLE:70 CFM FOR 2600 w _ <br /> 5F HOME w/4 BEDROOMS,AND THEN INCREASE BY FACTOR OF IS PER TABLE - `"3 = WHOLE W <br /> MSO6.4.3(2)TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED VENTILATION SYSTEM, MINI-SPLIT HOUSE <br /> 26, WHOLE HOUSE FAN SHALL BE I.0 50NES OR LESS, AND SHALL H 3,_I <br /> AVE AN EFFICACY OF 2.d 02 4'-5' FAN <br /> CFM/WATT PER WSEC R403.6.I. 2xbWALL 22"x30' CpT 3j' UTILITY ' D 1 - co <br /> 29. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOWS PER 5171al E m I� I� 1 <br /> CODE INTERPRETATION 17-15. -10" r 5D/CO ATTIC NS 2868 Q 5'3x9'7 <br /> 11"" ACCESS <br /> 30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE � � y_q+ 3,�, 2xb WALL <br /> WHOLE HOUSE FAN. 3-b 15R,14T <br /> 31. PER IRC MI502A5.:WHERE THE DRYER VENT EXHAUST DUCT IS CONCEALED WITHIN IHc - 4-0 MINI-SPLIT <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE 50'H i{2 V1ALL BF b q'-4" _ <br /> IDENTIFIED ON A PERMANENT LABEL OR TAG, THE LABEL OR TAG SHALL BE LOCATED a '_4 5'- W/5(3) <br /> WITHIN 6FT Of THE EXHAUST DUCT CONNECTION. 3'-I " 42'H HALF <br /> " a WALL TR <br /> 3 �Tpwl <br /> 2668 _ <br /> LIFE SAFETY �_? ' s <br /> OPEN TO 26. A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPERATURES.uND C BELOWCP7HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. = s e BEDROOM 227. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR 5PIOKE STAIRS w/ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROOM OR WINDER STEPS B'AT' q'7x13'2 <br /> 3�_6 WILL ALWAYS 5 OX911 _ - <br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION DOUBLE RIM OR 38"H HAVE A <br /> 10, SMOKE DETECTORS TO BE POV, INTERCONNECTED w/BATTERY BACKUP t CENTRALLY PROVIDE SPLICE I!2 WALL CON HAVE A <br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL 5MOKE DETECTORS SHALL BE - _ <br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 '.'' - INSLALLED ON T15 4-0 BF <br /> Il. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM THE _ SD/CO O5D <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER,CR3141 THE INSIDE OF <br /> 12. IONIZATION SMOKE ALARMS: b+ THE STAIR RUN 60'z32° <br /> + SHALL NOT BE IN5TALLED LESS THAN 20 FT HORIZONTALLY FROM A PERMANENTLY 'TUB/SHWR 2668 W%5(I) - <br /> 2x ALL <br /> INSTALLED COOKING APPLIANCE. ADD FLAT <br /> E IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH SHALL NOT BE INSTALLED 2X4 THROUGH + 4b68 3'-6' 2668 MI I-SPLIT <br /> LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIAiNCE. 2X4JOI T @ 5'O.C. 54 7'-bz" 5' 4'- '-IOV7' <br /> 24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LE55 THAN 6 FT _ 5D COPYRIGHT N9TCE TWS <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE CR3141 O PLAN 15 OWNED BY PACIFIC <br /> 25.GARAGE NOTE:WRAP ALL WARM WALL5 AND SUPPORTING MEMBERS WITH 112'G W.B.6 5/8" Y2nx�+ 05D RIDGE HME5,USE OF THIS <br /> TYPE'X'ON THE CEILING.POLY SEAL RIM,ENTIRE GARAGE TO MEET JUR15DICTION m o I �PAYMENT <br /> ED 5Y LAW <br /> DRAFT STOP REQUIREMENTS <br /> " I I LICENSE FEE TO PACIFIC <br /> 26. ENCL05ED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH Y2'GWB AT THE BEDROOM 4 I I BEDROOM 3 RIDGE 401�� <br /> WALLS,UNDER-STAIR SURFACES AND SOFFITS. STT HR5416Z. - I i-� i I ,IX°° <br /> 2T PROVIDE FIREBLOCKING PER PLAN AND @ ALL PLUMBING PENETRATIONS. SECTION TNRU IO4XII'4 m I- -I 97x1110' _ <br /> ATTACH To N u o _ PLAN SUMMARY <br /> 2x AND TO WALL CAP I� I - <br /> STAIR RIM i N/A <br /> 806 <br /> 7046 XOX(EGRESS) - 1075 nn. <br /> w/GRID PER ELEV. - 1, <br /> HALF WALL FRAMING It CAP DETAIL 4040 XO 185 <br /> V I.J SCALE:I/2'•I-0" LINE OF (EGRESS) w+rf.u.:a.IT., <br /> WALL BELOW w/GRID 424 <br /> PER ELEV. <br /> ELECTRIC <br /> Aeamcn+w.D.un caawemw <br /> JWA <br /> -PROVIDE MIN,30' ATTIC ACCESS , <br /> HEADROOM CLEARANCE. SHEATHING ON <br /> -TRU55E5 MST BE OUTSIDE OF BTL ENGINEERING <br /> INSTALLED @ 24'O.C. TRUSS MEMBERS 2 z' 7 0" 2'T SEE REVISION LOG <br /> O Q 2'-7" P-10' V-3" 4'-1' <br /> SCALE:Y"=V-0" <br /> 2'-10.�' Ib'-7Y° 10'-b' wriwis <br /> UPPER FLOOR PLAN <br /> 5/4 TRIEkq ATTIC <br /> OR SIM. ACCESS LID <br /> ATTIC ACCESS DETAIL UPPER FLOOR PLAN - 'A' '131 ELEV's <br /> - D3� SCALE:112'=I'-0' SCALE: 114'=1'-O' <br /> ('A' I 'B' ELEV's) <br />