Laserfiche WebLink
19011 Wood-Sno Itoad NE, Suite 100 <br />BTLWoodinville, VIA 98072-4436 <br />Phone:425-814-8448, <br />ENGINEERING Ipax:425-821-2120 <br />Stud Wall Design <br />Based on 2018 NDS Combined axial and bending formula: <br />[f,/F.']` + fb/Fb'[1-(fjFA1 < 1 in which: FEE=•0.822(Emin')/(f,/d)2 <br />Wall: Exterior Walls Wall Height: <br />Desired Stud Spacing: <br />No Fire Rating IV Design Axial Dead Load: <br />2x6 1W Design Axial Live Load: <br />SPF Stud .r Design Axial Snow Load: <br />Design Lateral Pressure (0.6W): <br />Deflection Criteria: L/ <br />STUD CHECK <br />edd <br />< <br />50 <br />OK <br />D+0.6W (Co = 1.60) <br />[fjF.'12 + fb/Fb'[1-(fdFcOl = <br />0.53 <br />< <br />1 <br />OK <br />fjF�E2 + (fb/FbEY = <br />0.00 <br />< <br />1 <br />OK <br />D+0.75L+0.75(0.6W)+0.75S (Co = 1.60) <br />[f,/Fj2 + fb/Fb'[1-(fjFcE)j = <br />0.92 <br />< <br />1 <br />OK <br />fjFVE2 + (fb/FbEY = <br />0.00 <br />< <br />1 <br />OK <br />D+0.75L+0.75S (CD = 1.16) <br />fc/Fc' = <br />0.72 <br />< <br />1 <br />OK <br />D+L (Ca = 1.0) <br />fdF,' = <br />0.71 <br />< <br />1 <br />OK <br />Deflection (No Increase for Load Duration): <br />Deft: L/ 240 = 0.45 <br />0,18 <br />< <br />0.45 <br />OK <br />oc <br />Checks Crushing for Stud Spacing` <br />No Stress Increase for Load Duration <br />Hem Fir Plates: f�/F.i = 0.87 < 1 OK <br />Douglas Fir Plates: fc/F�i = 0.56 < 1 OK <br />' Plate must also be checked for bending. <br />2 Check on crushing only applies to stud spacing, Joists above <br />must also be checked for crushing effect on plate. <br />Also, no stress increase is allowed due to load duration. <br />9ft <br />24 in oc <br />683 plf <br />960 plf <br />538 plf <br />15 psf <br />240 <br />Date: 1/27/2021 <br />Page: M 1.11 <br />