My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1701 121ST ST SE 2025-02-03
>
Address Records
>
121ST ST SE
>
1701
>
1701 121ST ST SE 2025-02-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 11:03:55 AM
Creation date
1/23/2025 10:44:15 AM
Metadata
Fields
Template:
Address Document
Street Name
121ST ST SE
Street Number
1701
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
264
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Dibble Engineers, Inc. Project Title: <br /> 1029 Market Street Engineer: <br /> Kirkland,WA 98033 Project ID: <br /> (425)828-4200 Project Descr: <br /> DO <br /> Wood Column Project File:23-079 Charter Club.ec6 <br /> LIC#:KW-06014989,Build:20.23.2.14 DIBBLE ENGINEERS INC. (c)ENERCALC INC 1983-2022 <br /> DESCRIPTION: COL 4 (BM4) <br /> Code References <br /> Calculations per NDS 2018,,IBC 2021,CBC 2022,ASCE 7-16 <br /> Load Combinations Used : IBC 2021 <br /> General Information _ <br /> Analysis Method Allowable Stress Design Wood Section Name 6x6 <br /> End Fixities Top&Bottom Pinned Wood Grading/Manuf. Graded Lumber <br /> Overall Column Height 16 ft Wood Member Type Sawn <br /> (Used for non-slender calculations) Exact Width In Allow Stress Modification Factors <br /> Wood Species Douglas Fir-Larch 5.50 <br /> Wood Grade No.i Exact Depth 5.50 in Cf or Cv for Bending 1.0 <br /> Fb+ 1,200.0 psi Fv 170.0 psi Area 30.250 in^2 Cf or Cv for Compressio: 1.0 <br /> Ix 76.255 in^4 Cf or Cv for Tension 1.0 <br /> Fb- 1,200.0 psi Ft 825.0 psi <br /> Fc-Prll 1,000.0 psi Density 31.210 pcf ly 76.255 in 4 Cm:Wet Use Factor 1.0 <br /> Fc-Per Ct:Temperature Fact 1.0 <br /> P 625.0 psi Cfu: Flat Use Factor 1.0 <br /> E:Modulus of Elasticity . . . x-x Bending y-y Bending Axial Kf: Built-up columns 1.0 1Vps 15 3 2 <br /> Basic 1,600.0 1,600.0 1,600.0ksi Use Cr: Repetitive 1 No <br /> Minimum 580.0 580.0 Brace condition for deflection(buckling)along columns: <br /> X-X(width)axis: Unbraced Length for buckling ABOUT Y-Y Axis= 16 ft,I, <br /> Y-Y(depth)axis: Unbraced Length for buckling ABOUT X-X Axis= 16 ft,N <br /> Applied Loads Service loads entered. Load Factors will be applied for calculations. <br /> Column self weight included : 104.90 Ibs* Dead Load Factor <br /> AXIAL LOADS . . . <br /> bm4: Axial Load at 16.0 ft, D = 1.440, Lr= 1.813, S = 2.266 k <br /> BENDING LOADS . . . <br /> Lat. Uniform Load creating Mx-x,W = 0.1230 k/ft <br /> DESIGN SUMMARY <br /> Bending&Shear Check Results <br /> PASS Max. Axial+Bending Stress Ratio = 0,6344 : 1 Maximum SERVICE Lateral Load Reactions. . <br /> Load Combination +D+0.750S+0.450W Top along Y-f 0.9840 k Bottom along Y-Y 0.9840 k <br /> Governing NDS Forumla Comp+ Mxx,NDS Eq. 3.9-3 Top along X-X 0.0 k Bottom along X-X 0.0 k <br /> Location of max.above base 8.054 ft Maximum SERVICE Load Lateral Deflections. .. <br /> At maximum location values are . Along Y-Y 1.503 in at 8.054 ft above base <br /> Applied Axial 3.244 k for load combination : W Only <br /> Applied Mx 1.771 k-ft <br /> Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base <br /> Fc:Allowable 369.087 psi for load combination : n/a <br /> Other Factors used to calculate allowable stresses. .. <br /> PASS Maximum Shear Stress Ratio= 0.1076 : 1 Bending Compression Tension <br /> Load Combination +D+0.60W <br /> Location of max.above base 0.0 ft <br /> Applied Design Shear 29.276 psi <br /> Allowable Shear 272.0 psi <br /> Load Combination Results <br /> Maximum Axial+Bendin4 Stress Ratios Maximum Shear Ratios <br /> Load Combination C D CID Stress Ratio Status Location Stress Ratio Status Location <br /> D Only 0.900 0.386 0.1470 PASS 0.0ft 0.0 PASS 16.0 ft <br /> +D+Lr 1.250 0.289 0.3069 PASS 0.0 ft 0.0 PASS 16.0 ft <br /> +D+S 1.150 0.312 0.3512 PASS 0.0 ft 0.0 PASS 16.0 ft <br /> +D+0.750Lr 1.250 0.289 0.2654 PASS 0.0 ft 0.0 PASS 16.0 ft <br /> +D+0.750S 1.150 0.312 0.2990 PASS 0.0 ft 0.0 PASS 16.0 ft <br /> +D+0.60W 1.600 0.231 0.6313 PASS 8.054 ft 0.1076 PASS 0.0 ft <br /> +D+0.750Lr+0.450W 1.600 0.231 0.5967 PASS 8.054 ft 0.08072 PASS 0.0 ft <br /> +D+0.750S+0.450W 1.600 0.231 0.6344 PASS 8.054 ft 0.08072 PASS 0.0 ft <br /> +0.60D+0.60W 1.600 0.231 0.5844 PASS 8.054 ft 0.1076 PASS 0.0 ft <br />
The URL can be used to link to this page
Your browser does not support the video tag.