Laserfiche WebLink
Dibble Engineers, Inc. Project Title: <br /> 1029 Market Street,Suite 200 Engineer: <br /> Kirkland,WA 98033 Project ID: <br /> T:(425)828-4200 Project Descr: <br /> www.dibbleengineers.com <br /> Wood Beam Project File:23-079 charter club.ec6 <br /> LIC#:KW-06014989,Build:20.23.08.30 DIBBLE ENGINEERS INC. (c)ENERCALC INC 1983-2023 <br /> DESCRIPTION: Typ joist <br /> Maximum Forces & Stresses for Load Combinations <br /> Load Combination Max Stress Ratios omen a ues ear Values <br /> Segment Length Span# M V CD CM Ct CLx CF Cfu C I C r M fb F'b V tv F'v <br /> +0.60D 1.00 1.00 1.00 1.300 1.00 0.80 1.15 0.0 0.00 0.0 0.0 <br /> Length=5.0 ft 1 0.027 0.017 1.60 1.00 1.00 1.00 1.300 1.00 0.80 1.15 0.03 44.2 1,626.6 0.02 3.3 192.0 <br /> Overall Maximum Deflections <br /> Load Combination Span Max."=Deft Location in Span Load Combination Max."+"Defl Location in Span <br /> +D+L 1 0.0816 2.518 0.0000 0.000 <br /> Vertical Reactions Support notation:Far left is#1 Values in KIPS <br /> Load Combination Support 1 Support 2 <br /> Max Upward from all Load Conditions 0.370 0.370 <br /> Max Upward from Load Combinations 0.370 0.370 <br /> Max Upward from Load Cases 0.333 0.333 <br /> D Only 0.037 0.037 <br /> +D+L 0.370 0.370 <br /> +D+S 0.120 0.120 <br /> +D+0.750L 0.287 0.287 <br /> +D+0.750L+0.750S 0.350 0.350 <br /> +0.60D 0.022 0.022 <br /> L Only 0.333 0.333 <br /> S Only 0.083 0.083 <br />