Laserfiche WebLink
TL 6 Long-period transition period(s) <br /> SsRT 1.369 Probabilistic risk-targeted ground motion(0,2s) <br /> SsUH 1.519 Factored uniform-hazard spectral acceleration(2%probability of <br /> exceedance in 50 years) <br /> SsD 3.966 Factored deterministic acceleration value(0.2s) <br /> S1RT 0,485 Probabilistic risk-targeted ground motion(1.0s) <br /> S1UH 0.54 Factored uniform-hazard spectral acceleration(2%probability of <br /> exceedance in 50 years) <br /> S1D 1.657 Factored deterministic acceleration value(1.0s) <br /> PGAd 1.343 Factored deterministic acceleration value(PGA) <br /> * See Section 11 A.8 <br /> The results indicated here DO NOT reflect any stale or local amendments to the values or any delineation lines made during the building code adoption <br /> process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. <br /> Please note that the ATC Hazards by Location website will not be updated to support ASCE 7-22, Find out why_. <br /> Disclaimer <br /> Hazard loads are provided by the U.S.Geological Survey Seismic s' Web Services. <br /> While the information presented on this website is believed to be correct,ATC and its sponsors and contributors assume no responsibility or liability for <br /> its accuracy.The material presented in the report should not be used or relied upon for any specific application without competent examination and <br /> verification of its accuracy,suitability and applicability by engineers or other licensed professionals.ATC does not intend that the use of this information <br /> replace the sound judgment of such competent professionals,having experience and knowledge in the field of practice,nor to substitute for the standard <br /> of care required of such professionals in interpreting and applying the results of the report provided by this website.Users of the information from this <br /> website assume all liability arising from such use.Use of the output of this website does not imply approval by the governing building code bodies <br /> responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. <br />