Laserfiche WebLink
Dibble Engineers, Inc. Project Title: <br /> 1029 Market Street Engineer: <br /> Kirkland,WA 98033 Project ID: <br /> 11, (425)828-4200 Project Descr: <br /> DEI <br /> Wood Column Project File:23-079 Charter Club.ec6 <br /> LIC#:KW-06014989,Build:20.23.2.14 DIBBLE ENGINEERS INC. (c)ENERCALC INC 1983-2022 <br /> DESCRIPTION: HDR3 As a COL <br /> Code References <br /> Calculations per NDS 2018,,IBC 2021,CBC 2022,4SCE 7-16 <br /> Load Combinations Used : IBC 2021 <br /> General Information <br /> Analysis Method Allowable Stress Design Wood Section Name 4x10 <br /> End Fixities Top&Bottom Pinned Wood Grading/Manuf. Graded Lumber <br /> Overall Column Height 6 It Wood Member Type Sawn <br /> (Used for non-slender calculations) Exact Width in Allow Stress Modification Factors <br /> Wood Species Douglas Fir-Larch 3.50 <br /> Exact Depth 9.250 in Cf or Cv for Bending 1.20 <br /> Wood Grade No.2 Area 32.375 inA2 Cf or Cv for Compressioi 1.0 <br /> Fb+ 875.0 psi Fv 170.0 psi Ix 230.840 inA4 Cf or Cv for Tension 1.10 <br /> Fb- 875.0 psi Ft 425.0 psi <br /> ly 33.049 in 4 Cm:Wet Use Factor 1.0 <br /> Fc-Prll 600.0 psi Density 31.210 pcf <br /> Ct:Temperature Fact 1.0 <br /> Fc-Perp 625.0 psi Cfu:Flat Use Factor 1.0 <br /> E:Modulus of Elasticity. .. x-x Bending y-y Bending Axial Kf:Built-up columns 1.0 NDS 15.3.2 <br /> Basic 1,300.0 1,300.0 1,300.0 ksl Use Cr:Repetitive? No <br /> Minimum 470.0 470.0 Brace condition for deflection(buckling)along columns: <br /> X-X(width)axis: Unbraced Length for buckling ABOUT Y-Y Axis=6 ft,K <br /> Y-Y(depth)axis: Unbraced Length for buckling ABOUT X-X Axis=6 ft,K <br /> Applied Loads Service loads entered. Load Factors will be applied for calculations. <br /> Column self weight included :42.101 Ibs' Dead Load Factor <br /> BENDING LOADS . . . <br /> Wind Load: Lat. Uniform Load creating My-y, W =0.1620 k/ft <br /> Lat. Uniform Load creating Mx-x, D =0.1875, S=0.3125 k/ft <br /> DESIGN SUMMARY <br /> Bending&Shear Check Results <br /> PASS Max.Axial+Bending Stress Ratio = 0.4548: 1 Maximum SERVICE Lateral Load Reactions.. <br /> Load Combination +D+S Top along Y-Y 1.50 k Bottom along Y-Y 1.50 k <br /> Governing NDS Forumla Comp+Mxx,NDS Eq.3.9-3 Top along X-X 0.4860 k Bottom along X-X 0.4860 k <br /> Location of max.above base 2.980 It Maximum SERVICE Load Lateral Deflections... <br /> At maximum location values are . Along Y-Y 0.04911 in at 3.020 ft above base <br /> Applied Axial 0.04210 k for load combination: +D+S <br /> Applied Mx 2.250 k-ft <br /> Applied My 0.0 k-ft Along X-X 0.1111 in at 3.020 ft above base <br /> Fc:Allowable 536.79 psi for load combination:W Only <br /> Other Factors used to calculate allowable stresses... <br /> PASS Maximum Shear Stress Ratio= 0.3555: 1 Bending Compression Tension <br /> Load Combination +D+S <br /> Location of max.above base 6.0 ft <br /> Applied Design Shear 69.498 psi <br /> Allowable Shear 195.50 psi <br /> Load Combination Results <br /> Maximum Axial+Bending Stress Ratios Maximum Shear Ratios <br /> Load Combination CD CP Stress Ratio Status Location Stress Ratio Status Location <br /> D Only 0.900 0.836 0.2171 PASS 2.980 ft 0.1703 PASS 6.0 ft <br /> +D+S 1.150 0.778 0.4548 PASS 2.980 ft 0.3555 PASS 6.0 ft <br /> +D+0.750S 1.150 0.778 0.3837 PASS 3.020 ft 0.2999 PASS 6.0 ft <br /> +D+0.60W 1.600 0.673 0.2895 PASS 2.980 ft 0.09582 PASS 6.0 ft <br /> +D+0.450W 1.600 0.673 0.2480 PASS 2.980 ft 0.09582 PASS 6.0 ft <br /> +D+0.750S+0.450W 1.600 0.673 0.4033 PASS 2.980 ft 0.2156 PASS 6.0 ft <br /> +0.60D+0.60W 1.600 0.673 0.2398 PASS 2.980 ft 0,05749 PASS 6.0 ft <br /> +0.60D 1.600 0.673 0.07415 PASS 3.020 ft 0.05749 PASS 6.0 ft <br /> I I I I, I <br />