Laserfiche WebLink
1901 t Wood-Sno Road NE,Suite 100 <br /> BYEWoodinville,WA 98072-4436 <br /> Phone:425-814-8448 <br /> E NCINEERIN G Fax:425-821-2120 <br /> Benton Square TH Revision Date: 1/11/2021 <br /> Unit Type 'B' <br /> Criteria <br /> Code: 2018 IBC <br /> Allowable Stress Design(ASD) <br /> Seismic Design: ASCE 7-16: 12.8 Equivalent Lateral Force Procedure <br /> Wind Design: ASCE 7-16: Ch.28 Envelope Procedure, Low Rise <br /> Risk Category: II-Other Structures � Table 1.5-1 <br /> Snow Importance Factor is = 1.00 Table 1.5-2 <br /> Ice Importance Factor-Thickness /; = 1.00 Table 1.5-2 <br /> Ice Importance Factor-Wind /W = 1.00 Table 1.5-2 <br /> Seismic Importance Factor le = 1.00 Table 1.5-2 <br /> Spectral Response, Short Period Ss = 1.392 (Mapped) <br /> Spectral Response, 1-s Period S = 0.495 (Mapped) <br /> Site Class based on Geotechnical Repoli ►� <br /> Site Class: D Table 20.3-1 <br /> Site Coefficient Fa = 1.02 Table 11.4-1 <br /> Site Coefficient F = 1.81 Table 11.4-2 <br /> Structural Systems: <br /> Light framed walls with shear panels <br /> All other structural systems r TL = 6 (Figs. 22-14 thru 22-17) <br /> Response Modification Coefficient R = 6.5 Table 12.2-1 <br /> Overstrength Factor S2o = 3 Table 12.2-1 <br /> Deflection Amplification Factor Cd = 4 Table 12.2-1 <br /> Basic Wind Speed: 100 mph <br /> Exposure to Wind: Exposure 8 �' Section 26.7.3 <br /> Topographical Factor KZT= 1.00 <br /> Date: 5/30/2023 <br /> Page: 1-1.1 43 <br />