Laserfiche WebLink
19011 Wood-Sno Road NE,Suite 100 <br /> BYE Woodinville,WA 9 8072-443 6 <br /> Phone:425-814-8448 <br /> E NCI NEERIN G Fax:425-821-2120 <br /> Benton Square I H Revision Date: 1/11/2021 <br /> Unit Type'B' <br /> Ps=A Kz1 Ps3o� (28.5-1) Exposure= B <br /> A= 1.02 (Fig.28.5.1) Mean Roof Ht hn(ft)= 32 ft <br /> x�, = 1.00 (Section 26.8) a(roof)= 3.0 ft <br /> a(upper/main floor)= 3.0 ft <br /> Basic Wind Speed= 100 mph <br /> Roof Angle= 19 <br /> North/South Loading Z8,54 Minimum Design Coods <br /> Zone Area D P. P Force#) ASD Force f>) Force(4) ASO Force(0) <br /> Roof A_ 24 21,6 21.6 22.0 528 317 384 230 <br /> Agable 27 21.6 21,6 22.0 594 357 432 259 <br /> B 54 -6 0 0-0 0.0 0 0 432 259 <br /> Cwall 40 14,3 14..3 14.6 585 351 640 384 <br /> Cgable 33 14.3 14,3 14.6 483 290 526 317 <br /> D 31 3.3 0.0 0.0 0 0 246 149 <br /> Total Area= 209 Total Load= 2190 1314 2664 1598 <br /> Design: 26CA 2598 <br /> Zone Area P. ps P Of) p psf Force 10) ASD Force 1#1 Force(#) ASD Farce f#) <br /> Floor 3 Awall 59 21.6 21.6 22.0 1299 779 944 566 <br /> Agable 0 21,6 21,6 22.0 0 0 0 0 <br /> B 0 -6A 0.0 0.0 0 0 0 0 <br /> Cwall 98 14.3 14.3 14.6 1438 663 1573 944 <br /> Cgable 0 14.3 14.3 14.6 0 0 0 0 <br /> D 0 -3.3 0.0 0.0 0 0 0 0 <br /> Total Area= 157 Total Load= 2737 1642 2517 1510 <br /> Design; 2737 1642 <br /> Zone Area Ply( sf) P< n...(PS9 P fpsn Force(#f ASD Force(0) Force(#1 ASD Farce(9) <br /> Floor 2 Awall 59 21.6 21.6 22,0 1299 779 944 566 <br /> Agable 0 21.6 21.6 22.0 0 0 0 0 <br /> 8 0 -5.0 0.0 0.0 0 0 0 0 <br /> Cwall 98 14.3 14.3 14.6 1438 863 1573 944 <br /> Cgable 0 14.3 14.3 14.6 0 0 0 0 <br /> D 0 -3.3 0.0 0 0 0 0 0 0 <br /> Total Area= 157 Total Load= 2737 1642 2617 1510 <br /> Design: 2737 164Z <br /> East)West Loading 29.5.4 Minimum Deypn toad, <br /> Zone Area P.'i(Psf) A (P5f) P(w Force(a) ASD Force(0) Force 10) ASD Fevre(# <br /> Roof Awall 24 21,6 21.6 22.0 528 317 384 230 <br /> Agable 27 21.6 216 22.0 594 357 432 259 <br /> B 0 -6.0 0.0 0,0 0 0 0 0 <br /> Cwall 152 14,3 14.3 14,6 2223 1334 2432 1459 <br /> Cgable 173 14..3 14,3 14.6 2530 1516 2768 1661 <br /> D 0 -3.3 0,0 0,0 0 0 0 0 <br /> Total Area= 376 Total Load= 5876 3526 6016 3610 <br /> -Design: 6016 3610 <br /> Zone Area P.,(psfl a (osrl P(psf) Force(A) ASD Force(#T Force(#T ASD Force(#) <br /> Floor 3 Awall 55 21.6 21.6 22.0 1211 726 880 528 <br /> Agable 0 216 21.6 22.0 0 0 0 0 <br /> 8 0 -5 0 0.0 0.0 0 0 0 0 <br /> Cwall 378 14.3 14.3 14.6 6624 3314 6043 3626 <br /> Cgable 0 14.3 14.3 14.6 0 0 0 0 <br /> D 0 -3.3 0-0 0.0 0 0 0 0 <br /> Total Area= 433 Total Load= 6735 4041 6923 4154 <br /> Design: 6923 4154 <br /> Zore Area P... Psr1 P­1:.{pst) P f ps4 Force(#) ASD Force(#J Farce(#J A5D Force(#j <br /> Floor 2 Awall 59 21.6 21.6 22.0 1299 779 944 566 <br /> Agable 0 21.6 21.6 22.0 0 0 0 0 <br /> B 0 -6.0 0.0 0.0 0 0 0 0 <br /> Cwall 358 14.3 14.3 14.6 5232 3139 5723 3434 <br /> Cgable 0 14.3 14.3 14.6 0 0 0 0 <br /> 0 0 -3.3 0.0 0.0 0 D 0 0 <br /> 7uf Area c 417 TWal Load- UN 3910 6567 40CC <br /> Design" 6667 4" <br /> Date: 5/30/2023 <br /> Page: L1.4 Fj <br />