19011 Wood-Sno Road NE,Suite 100 <br /> Woodinville,WA 98072-4436 <br /> Phone:425-814-8448 <br /> E N G I N E E RIN C Fax:425-821-2120 <br /> Benton Square TH Revision Date: 1/11/2021 <br /> Unit Type V <br /> Criteria <br /> Code: 2018 IBC <br /> Allowable Stress Design(ASD) <br /> J <br /> Seismic Design: ASCE 7-16: 12.8 Equivalent Lateral Force Procedure <br /> Wind Design: ASCE 7-16: Ch. 28 Envelope Procedure, Low Rise <br /> Risk Category: II-other Structures !� Table 1.5-1 <br /> Snow Importance Factor is = 1.00 Table 1.5-2 <br /> Ice Importance Factor-Thickness l; = 1.00 Table 1.5-2 <br /> Ice Importance Factor-Wind 1, = 1.00 Table 1.5-2 <br /> Seismic Importance Factor le = 1.00 Table 1.5-2 <br /> Spectral Response, Short Period Ss = 1.392 (Mapped) <br /> Spectral Response, 1-s Period St = 0,495 ":(Mapped) <br /> Site Class based on Geotechnical Report <br /> Site Class: D • Table 20.3-1 <br /> Site Coefficient Fa = 1.02 Table 11.4-1 <br /> Site Coefficient F, = 1.81 Table 114-2 <br /> Structural Systems: <br /> Light framed walls with shear panels <br /> All ather structural systems V TL =6 (Figs. 22-14 fhru 22-17) <br /> Response Modification Coefficient R = 6.5 Table 12.2-1 <br /> Overstrength Factor f2o = 3 Table 12.2-1 <br /> Deflection Amplification Factor Cd = 4 Table 12.2-1 <br /> Basic Wind Speed; 100 mph <br /> Exposure to Wind: Exposure B 1w Section 26.7.3 <br /> Topographical Factor KzT= 1.00 <br /> Date: 5/30/2023 <br /> Page: L1.1 13 <br />