My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 SE EVERETT MALL WAY HERITAGE BANK 2025-01-24
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
HERITAGE BANK
>
906 SE EVERETT MALL WAY HERITAGE BANK 2025-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2025 8:17:23 AM
Creation date
1/24/2025 7:50:51 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Tenant Name
HERITAGE BANK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LL <br /> CO <br /> v LL 0 <br /> HERITAGE BANK STE 501 <br /> Y U <br /> U � <br /> M � <br /> m <br /> FIRE ALARM SYSTEM OPERATIONAL MATRIX GENERAL NOTES <br /> N <br /> ALARM TROUBLE SUPERVISORY MISCELLANEOUS 1.FACTORY RECOMMENDED MINIMUM WIRING SIZES,TYPE AND 7.PARALLEL BRANCHING OF WIRE TO ALL NOTIFICATION APPLIANCE Q <br /> CONSTRUCTION AS NOTED ON THE DRAWINGS MUST BE STRICTLY CIRCUITS SHALL NOT BE PERMITTED. o <br /> FOLLOWED.ANYONE WILLING TO MAKE CHANGES WILL DO SO AT <br /> O 1"SSO THEIR OWN RISM 8.PARALLEL BRANCHING OF WIRE TO ADDRESSABLE INITIATING DEVICE <br /> CIRCUITS IS PERMISSIBLE. w <br /> 2.THE CIRCUIT ROUTING AND WIRING COUNTS ON THE FLOOR PLAN Cn <br /> z w DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND 9.PER NFPA 72,SECTION 29.8.3.4(7):SMOKE ALARMS AND SMOKE p <br /> QO 0 4i4 ��w SHORTEST POSSIBLE ROUTING FROM THE CONTROL PANEL AND DETECTORS SHALL NOT BE INSTALLED WITHIN A 361N.(91 OMM) ( �1 <br /> OQ {U5 S Y G 5� 5 BETWEEN CONNECTED FIELD DEVICES WITH NO PHYSICAL HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR > o <br /> �S l�ti �yG�Sw PG4�S1�44 y� OBSTRUCTIONS.THE WIRING OR CIRCUIT COUNTS(IF SHOWN)ARE HEATING OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF � <br /> PROVIDED AS A CONVENIENCE ONLY AND AS MEANS TO HASTEN THE DIRECT AIRFLOW FROM THOSE REGISTERS. o <br /> INSTALLATION OR TO DETERMINE WIRING ROUTES. <br /> 10.SMOKE ALARMS AND CO-DETECTION WILL BE INSTALLED BY <br /> 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS ELECTRICAL CONTRACTOR. <br /> LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE o <br /> 4 P P 4v4v4v 4�4�4� <br /> PERMITTED. 11.THE AUDIBLE ALARM NOTIFICATION APPLIANCES SHALL PROVIDE A <br /> CAUSE Q�Q� �¢�¢�¢O y�y�y�4 �.��.�y�$ REMARKS SOUND PRESSURE LEVEL OF 15 DECIBELS(dBA)ABOVE THE AVERAGE <br /> 4.PER NFPA 72,SECTION 17.7.1.11.3:WHERE DETECTION IS NOT AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL <br /> SMOKE HEAT DETECTORS • • • • • REQUIRED DURING CONSTRUCTION,DETECTORS SHALL NOT BE HAVING A DURATION OF NOT LESS THAN 60 SECONDS,WHICHEVER IS <br /> MANUAL PULL STATION • • • • • INSTALLED UNTIL AFTER ALL OTHER CONSTRUCTION TRADES HAVE GREATER,IN EVERY OCCUPIABLE SPACE WITHIN THE BUILDING.IN <br /> SYSTEM RESET • COMPLETED CLEANUP. COMPLIANCE WITH CURRENT IFC AND NFPA 72 CODES. <br /> SIGNAL SILENCE • • 5.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE <br /> AC POWER FAILURE • • • LATEST U.L.,N.E.C.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS <br /> FIRE ALARM TROUBLE(OPEN, APPLICABLE TO THE CITY STANDARDS. Z <br /> SHORTS,OR GROUNDS)ON • • • - rw LL <br /> INITIATION OR SIGNALING CIRCUITS 6.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, <br /> TAMPER SWITCHES • • • FACTORY AVAILABILITY,ETC.WE RESERVE THE RIGHT TO SUBSTITUTE z_ _ <br /> WATERFLOW SWITCH • • • li• • EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH EQUIPMENTOF - - <br /> EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. 3 <br /> SCOPE OF WORK: = 3 g <br /> -RELOCATE EX. NOTIFICATION AS SHOWN _ <br /> -ADD FIRE ALARM A/V NOTIFICATION TO NEW CORRIDOR <br /> -RELOCATE EX. FIRE ALARM INITIATING AS SHOWN <br /> FIRE ALARM DEVICE LEGEND <br /> SYMBOL QTY DESCRIPTION MODEL NUMBER MANUFACTURER BACKBOX MOUNTING HEIGHT Z <br /> AC EX FIRE ALARM CONTROL PANEL 101000 EST EX EX J <br /> NAC# EX NOTIFICATION CKT POWER BOOSTER EBPS6A EST EX EX d <br /> o EX T cc <br /> 3o=a d 3 HORN STROBE-CEILING MOUNT EGCF-HDVM EST 4S BOX CEILING O Q <br /> LLI <br /> EX LO <br /> Cn <br /> 1 STROBE-CEILING MOUNT EGCF-VM EST 4S BOX CEILING LLI <br /> \'E a OH EX HEAT DETECTOR PSDA EST 4S BOX CEILING ~ J <br /> S EX PHOTO SMOKE SIGA-PS EST 4S BOX CEILING (n C co z <br /> c0 EX Z <br /> Y H 00 Q <br /> Eca aw °' IL <br /> m LU a <br /> C° SEX <br /> Lu � <br /> °�EX LU LU J ca t r Mr '^ M a <br /> c0 EX IY LU LU <br /> Lu E <br /> O 2 T W LL <br /> Accentuate with Ash <br /> T <br /> ',/ O Corne Relax at <br /> 10 <br /> Our Day Spa <br /> a Evergreen �pplebec'=Gnil Ba. <br /> Q <br /> '� a Beauty College � <br /> 015c • ~ E o <br /> JULES MAYER,SET <br /> FCPS#5 CKT 41 <br /> EK J� Modem Home Furniture United Seattle NICETLARM S3 0 C o <br /> FIRE ALARM SYSTEMS.LEVEL IV CCU o <br /> EePsea NAC CIRCUIT <br /> PARE a4ARec Fumilure store r..t <br /> POWER <br /> A SUPPLY NAC# Everett vet Center vQ <br /> FRCP <br /> Esr g a v <br /> °'°°° B Metal Supermarkets ^� r..r <br /> FIREALARM EX x21 EX EX x2 .4 <br /> C PAYELOI S H S Everett 0 <br /> P P ^ <br /> W 5 <br /> Vf � <br /> 120 VAC -` <br /> 20 AMP DEDICATED CIRCUIT <br /> THE CIRCUIT RUUTING AND WIRING COUNTS ON THE <br /> FLOOR PLAN DRAWINGS ARE SHOWN DIAGRAMMATIC <br /> BASED ON CONTINUOUS AND SHORTEST POSSIBLE <br /> RUUTING FROM THE CONTROL PANEL AND BETWEEN <br /> FIRE ALARM RISER VICINITY MAP CONNECTED FIELD DEVICES WITH ND PHYSICAL 44 <br /> ❑BSTRUCTIONS. THE WIRING OR CIRCUIT COUNTS <br /> (IF SHOWN) ARE PROVIDED AS A CONVENIENCE <br /> ONLY AND AS MEANS TO HASTEN INSTALLATION <br /> OR TD DETERMINE WIRING ROUTS. ALL FIRE ALARM <br /> WIRING CAN BE RAN IN SAME CONDUIT. <br />
The URL can be used to link to this page
Your browser does not support the video tag.