My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 SE EVERETT MALL WAY HERITAGE BANK 2025-01-24
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
HERITAGE BANK
>
906 SE EVERETT MALL WAY HERITAGE BANK 2025-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2025 8:17:23 AM
Creation date
1/24/2025 7:50:51 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Tenant Name
HERITAGE BANK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Option Cards <br /> EDWARDS iO Series panels are supported by a complete line RZI16-2 Remote Zone Interface Module <br /> of modules and related equipment that enhance performance <br /> and extend system capabilities. Option cards plug directly into :a_ <br /> the control panel main circuit board or are connected to it with aribbon cable.After installation,terminals remain accessible.Thecabinet provides ample room for wire routing, keeping wiring neatat all times. <br /> o <br /> Single and Dual Loop Controller Cards The RZI16-2 Addressable Remote Zone Interface Module is an <br /> The iO-SDC1 is a single loop controller card that can be used with addressable device that provides connections for sixteen Class B <br /> the i064 as a replacement for the standard 64-point loop, or with Initiating Device Circuits and two Class B Supervised Output <br /> the i01000 as a 250-point expansion module. Circuits.The inputs and outputs can be configured individually for <br /> The iO-SDC2 is a 500-point dual loop controller card for the several device types. <br /> i01000 that provides two SLC circuits,each with 125 detector It requires 18 consecutive addresses on the Signaling Line Circuit <br /> addresses and 125 module addresses. (SLC).Addresses are assigned electronically.There are no address <br /> switches to set. <br /> Specifications 10-SDC1 iO-SDC2 <br /> Device Addresses i01000:one loop,250 01000:two loops, The RZI16-2 incorporates two 8-segment DIP switches that are <br /> device addresses 500 device addresses used to select the Alarm or Supervisory default device type for <br /> 064:64 addresses each of the 16 IDC circuits.The module also includes one 4-seg- <br /> Wiring Class B or Class A ment DIP switch used to select the default Relay or NAC output <br /> Operating Voltage 24 VDC device type. Device types other than the default are accomplished <br /> Operating Current Standby:55 mA Standby:45 mA through programming. <br /> (fully loaded loop) Alarm:80 mA Alarm:70 mA <br /> Note:These ratings do not include the use of two-wire smoke modules. RZI16-2 Specifications <br /> Communication Line Max.20.6 V peak-to-peak Voltage <br /> Voltage 24V/Aux nominal: 24 VDC <br /> Terminal Rating 12 to 18 AWG(0.75 to 2.5 mmz) Supervisory current: 250 mA at 24 VDC nominal <br /> Alarm Current 1000 mA <br /> Circuit Current 0.5 A max. 24V/Aux minimum: 18.4 VDC <br /> Max total loop 66 Q 24V/Aux maximum: 26.4 VDC <br /> resistance NAC1, NAC2 nominal: 24 VDC <br /> Max total loop 0.5 uF Current <br /> capacitance Standby current <br /> Isolators 64 isolators maximum per loop(total both for 4.7 k EOL(U.S.) 4.8 mA/circuit <br /> isolator bases and modules) Standby current for <br /> Ground Fault 0 to 5 kn 3.9 k EOL(Canada) 5.7 mA/circuit <br /> Impedance Alarm current <br /> Operating 32 to 120°F(0 to 49°C) at nominal voltage 31.1 mA/circuit <br /> Environment 0 to 93%noncondensing at 90°F(32°C) Relay outputs <br /> Quantity 2 <br /> Type Rating(pilot duty) Programmable 24 VDC at 2.5 A <br /> Input circuit wiring 25 D per wire <br /> SA-ETH Ethernet Interface Card resistance <br /> SA-ETH wiring The SA-ETH card provides a Initiating device circuits <br /> To network standard 10/100 Base T Ether- Quantity 16 <br /> Network cable fg connection <br /> net network connection for EOL resistor 4.7 1<4(U.S.);3.9 1<4 Canada <br /> connecting to an intranet,a local Zone voltage 22.78 V for 4.7 kO(U.S.) <br /> I network, or the Internet.The 22.08 V for 3.9 kO(Canada) <br /> + card can be used to download Alarm current 31.1 mA/channel at nominal voltage <br /> Alarm impedance range <680 f2 <br /> 0l�lf� configuration programming from Trouble impedance range >5.55 kf2 <br /> ° ® the iO-CU to the panel. Supervised output circuits <br /> ❑n The Ethernet card is installed on EOL resistor 15<0 <br /> ® the plastic assembly and con- Quantity 2 <br /> ® Short circuit detection <2.6 kf2 <br /> nects to the main circuit board Open circuit detection >61.9 k0 <br /> Ethernet card via a ribbon cable. Contact ratings 24 VDC at 2.5 A(5 A for two NACs) <br /> SA-ETH specifications Compatible cabinets MFC(A),i01000,APS <br /> Ethernet 10/100 Base T <br /> Operating environment <br /> Temperature 32 to 120°F(0 to 49°C) <br /> Humidity 0 to 93%RH,noncondensing at 90°F <br /> (32°C) <br /> Page 5 of 8 DATA SHEET E85001-0135 <br /> Not to be used for installation purposes. Issue 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.