Permit#: FA2406-001 <br /> Site Address: 906 BE Everett Mall Way Ste 501 UL CO <br /> Applicant: Jules Mayer <br /> Application Date:0610312024 LL 0 <br /> Description: Relocate Ex F/A AN notification and <br /> initiating.Add notification to new corridor. <br /> Review Date: 06/03/2024 <br /> HE <br /> EV IT <br /> ERETT & <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 06/03/2024 3:08:23 <br /> HERITAGE BANK STE 501PM <br /> Y U <br /> U � <br /> r � <br /> m <br /> FIRE ALARM SYSTEM OPERATIONAL MATRIX GENERAL NOTES <br /> N <br /> ALARM TROUBLE SUPERVISORY MISCELLANEOUS 1.FACTORY RECOMMENDED MINIMUM WIRING SIZES,TYPE AND 7.PARALLEL BRANCHING OF WIRE TO ALL NOTIFICATION APPLIANCE Q <br /> CONSTRUCTION AS NOTED ON THE DRAWINGS MUST BE STRICTLY CIRCUITS SHALL NOT BE PERMITTED. o <br /> FOLLOWED.ANYONE WILLING TO MAKE CHANGES WILL DO SO AT <br /> O 1"SSO THEIR OWN RISKP 8.PARALLEL BRANCHING OF WIRE TO ADDRESSABLE INITIATING DEVICE <br /> CIRCUITS IS PERMISSIBLE. w <br /> 2.THE CIRCUIT ROUTING AND WIRING COUNTS ON THE FLOOR PLAN Cn <br /> z w <br /> DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND 9.PER NFPA 72,SECTION 29.8.3.4(7):SMOKE ALARMS AND SMOKE U <br /> QO 0 4i4 ��w SHORTEST POSSIBLE ROUTING FROM THE CONTROL PANEL AND DETECTORS SHALL NOT BE INSTALLED WITHIN A 361N.(91 OMM) (n a,I <br /> OQ {U5 S Y G 5� 5 BETWEEN CONNECTED FIELD DEVICES WITH NO PHYSICAL HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR > o <br /> �yG�Sw PG4�S1�44 y� OBSTRUCTIONS.THE WIRING OR CIRCUIT COUNTS(IF SHOWN)ARE HEATING OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF � <br /> co Q O 1�� PROVIDED AS A CONVENIENCE ONLY AND AS MEANS TO HASTEN THE DIRECT AIRFLOW FROM THOSE REGISTERS. o <br /> INSTALLATION OR TO DETERMINE WIRING ROUTES. <br /> 10.SMOKE ALARMS AND CO-DETECTION WILL BE INSTALLED BY <br /> 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS ELECTRICAL CONTRACTOR. <br /> LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE zz o <br /> 4 P P 4v4v4v 4�4�4� <br /> PERMITTED. 11.THE AUDIBLE ALARM NOTIFICATION APPLIANCES SHALL PROVIDE A <br /> CAUSE Q�Q� �¢�¢�¢O y�y�y�4 �.��.�y�$ REMARKS SOUND PRESSURE LEVEL OF I5 DECIBELS(dBA)ABOVE THE AVERAGE <br /> 4.PER NFPA 72,SECTION 17.7.1.11.3:WHERE DETECTION IS NOT AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL <br /> SMOKE HEAT DETECTORS • • • • • REQUIRED DURING CONSTRUCTION,DETECTORS SHALL NOT BE HAVING A DURATION OF NOT LESS THAN 60 SECONDS,WHICHEVER IS <br /> MANUAL PULL STATION • • • • • INSTALLED UNTIL AFTER ALL OTHER CONSTRUCTION TRADES HAVE GREATER,IN EVERY OCCUPIABLE SPACE WITHIN THE BUILDING.IN <br /> SYSTEM RESET • COMPLETED CLEANUP. COMPLIANCE WITH CURRENT IFC AND NFPA 72 CODES. <br /> SIGNAL SILENCE • • 5.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE <br /> AC POWER FAILURE • • • LATEST U.L.,N.E.C.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS <br /> FIRE ALARM TROUBLE(OPEN, APPLICABLE TO THE CITY STANDARDS. Z <br /> SHORTS,OR GROUNDS)ON • • • w rw LL <br /> INITIATION OR SIGNALING CIRCUITS 6.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, <br /> TAMPER SWITCHES • • • FACTORY AVAILABILITY,ETC.WE RESERVE THE RIGHT TO SUBSTITUTE z_ _ <br /> WATERFLOW SWITCH • • • • • EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH EQUIPMENTOF - - <br /> EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. 3 <br /> o <br /> SCOPE OF WORK: o = 3 g <br /> —RELOCATE EX. NOTIFICATION AS SHOWN _ <br /> —ADD FIRE ALARM A/V NOTIFICATION TO NEW CORRIDOR <br /> -RELOCATE EX. FIRE ALARM INITIATING AS SHOWN <br /> FIRE ALARM DEVICE LEGEND <br /> SYMBOL QTY DESCRIPTION MODEL NUMBER MANUFACTURER BACKBOX MOUNTING HEIGHT Z <br /> AC EX FIRE ALARM CONTROL PANEL 101000 EST EX EX J <br /> NAC# EX NOTIFICATION CKT POWER BOOSTER EBPS6A EST EX EX d <br /> 0 EX T M <br /> 30=4 d 3 HORN STROBE-CEILING MOUNT EGCF-HDVM EST 4S BOX CEILING O Q LLI <br /> LLI <br /> EX LO <br /> Cn <br /> 1 STROBE-CEILING MOUNT EGCF-VM EST 4S BOX CEILING LLI <br /> \�E a OH EX HEAT DETECTOR PSDA EST 4S BOX CEILING ~ J <br /> S EX PHOTO SMOKE SIGA-PS EST 4S BOX CEILING (n 2 co z <br /> c0 EX Z <br /> Y I— 00 Q <br /> Ectl aw °' IL <br /> m m a° EX 2 <br /> LIu > m <br /> EX `a` LU <br /> �L/L�I li- J cd t r Mry V/ Li <br /> c0 EX 1Ii 0 LU LU <br /> Lu E <br /> O 2 T W LL <br /> Accentuate with Ash <br /> Corne Relax at <br /> �o <br /> T Our Day Spa <br /> Evergreen <br /> r'pplebec'=Gail Ba. <br /> QBeauty College it <br /> o 15c • ~ E o <br /> JULES MAYER,SET Vl <br /> FCPS#5 CKT 41 r.., - ���e <br /> Er J� Modem Home Furniture United Seattle NICETY g130993 C o <br /> FIRE ALARM SYSTEMS.LEVEL IV CCU o <br /> EUPs6A NAC CIRCUIT <br /> FIRE&MZM Fumilure store <br /> POWER Q C S :g o <br /> SUPPLY NAC# <br /> A Everett vet Center <br /> FRCP <br /> esr <br /> °I°°° B Metal Supermarkets ^� r..r <br /> FIRE ALARM EX x24 EX EX x2 <br /> C PAYELOI S H S Everett 0 <br /> #A Vf � <br /> 120 VAC -` <br /> 20 AMP DEDICATED CIRCUIT <br /> THE CIRCUIT RUUTING AND WIRING COUNTS ON THE <br /> FLOOR PLAN DRAWINGS ARE SHOWN DIAGRAMMATIC <br /> BASED ON CONTINUOUS AND SHORTEST POSSIBLE <br /> RUUTING FROM THE CONTROL PANEL AND BETWEEN <br /> FIRE ALARM RISER VICINITY MAP CONNECTED FIELD DEVICES WITH ND PHYSICAL 44 <br /> ❑BSTRUCTIONS. THE WIRING OR CIRCUIT COUNTS <br /> (IF SHOWN) ARE PROVIDED AS A CONVENIENCE <br /> ONLY AND AS MEANS TO HASTEN INSTALLATION <br /> OR TD DETERMINE WIRING ROUTS. ALL FIRE ALARM <br /> WIRING CAN BE RAN IN SAME CONDUIT. <br />