My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9914 18TH AVE W B 2023 Plans 2025-02-03
>
Address Records
>
18TH AVE W
>
9914
>
Plans
>
9914 18TH AVE W B 2023 Plans 2025-02-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 9:41:33 AM
Creation date
1/24/2025 8:13:40 AM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9914
Unit
B
Permit
B2308-058
Year
2023
Notes
NEW TOWNHOUSE COMMUNITY - BENTON SQUARE BUILDING A - UNIT B
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GRAPHIC SYMBOLS O <br /> I DRAWING DRAWING DRAWING-Al " me a <br /> NUMBER- NUMBER NUMBER <br /> Al DETAIL Al SECTION A2 A7o1 A4 INTERIOR <br /> ELEVATION I STREET-FACING FACADES OF RESIDENTIAL BUILDINGS DESIGNED TO LOOK AS <br /> l I A101 A101 <br /> SHEET �� SHEET A SERIES OF BUILDINGS NO WIDER THAN 50 FEET EACH(EMC 19.09.020(B)(2)) ¢cc <br /> SHEET NUMBER NUMBER q3 3ZIll. I I-p�� I Q <br /> NUMBER 1 <br /> o] <br /> _ Name Room name ROOM NAME& a z <br /> Elevation LEVEL [1011 NUMBER DOOR TYPE o a <br /> 0 REVISION EK WINDOW TYPEse <br /> APPLICABLE CODES: ACCESSIBILITY REQUIREMENTS: _ m3 <br /> a <br /> ALL CONSTRUCTION SHALL CONFORM TO THE FOLLOWING None applicable per the scoping requirements of the m <br /> APPLICABLE CODES®ULATIONS: Federal Fair Housing Act or International Building Code <br /> -_ ..._.. <br /> (18C).ANSI A117.1 does not establish scoping. <br /> •2018 International Residential Code - <br /> •Washington State amendments h the IRC,Chapter amendments <br /> WAC Section R320.1occupancy; <br /> of the 2018 IRC defers to IBC chapter 11 ® - <br /> •2018 International Fire Code with statewide amendments for R-3 occupancy; 1 <br /> •2018 Was <br /> State Energy Code IBC1107.6.3 allows reduction of Type B dwelling unit <br /> 77 <br /> wV <br /> •2020 National Electrical Code requirement per section 1107; ITM1 - - <br /> N <br /> •Snohomish County Municipal Code 1107.7.2 exempts multistory dwelling units without .r <br /> - elevator service from Type B requirements. See also <br /> ICC IBC commentary for section 1107.7.2. <br /> '! ! <br /> " C BUILDING CODE ANALYSIS: E-_I Ca <br /> MECHANICAL,PLUMBING& <br /> IRC SECTION R302 ELECTRICAL NOTES: <br /> 23'-2" <br /> Exterior Walls: 1-HR Rated when<T separation 1 <br /> GENERAL NOTES PILASTERS&RECESSED ENTRIES PROVIDE HORIZONTAL ARTICULATION AT<25' <br /> Projections: 1-HR Rated underside when 2'to<3' 1. Detailed mechanical,plumbing and fire protection (EMC 19.09.020(B)(1)&19.12.040(B)) <br /> separation design&component selection shall be provided by ,;-,DESIGN STANDARDS-FRONT <br /> Dwelling Unit Either a double wall consisting of(2)1- the mechanical and plumbing contractors on a design- 3/32"=1'-0" <br /> separation walls: HR rated walls OR a 2-HR Rated build basis.Contractors shall be responsible for <br /> Common wall(t-HR if sprinklered)per obtaining any required permits. STREET-FACING FACADES OF RESIDENTIAL BUILDINGS DESIGNED TO LOOKAS <br /> 2. All appliances and equipment shall be approved by a <br /> IRC ductwoR302.2rk <br /> exception 5,no plumbing nationally recognized testing lab. A SERIES OF BUILDINGS NO WIDER THAN 50 FEET EACH(EMC 19.09.020(8)(2)) <br /> or ductwork inside party walls,rating 3. All piping and ducting shall be run in concealed <br /> shall be continuous the full length of party wall&from foundation to spaces. Provide atio balancing valves and the <br /> underside of roof sheathing like in accessible locations. <br /> LLI <br /> U <br /> 4. HVAC ducts penetrating one-hour rated assemblies <br /> Garage Separation: 20 min.door with self closing device, shall be minimum 26ga galvanized steel. <br /> penetrating ductwork shall be 26ga min. 5. Party walls between individual resident units shall not w z <br /> Separation from adjacent space:112" contain plumbing or mechanical equipment,ducts or Q <br /> GWB vents in the cavity of the common wall. WEATHER PROTECTION AT 0 J <br /> Separation from habitable rooms PIUBLIC STREET-FACING r O <br /> above:5/8"Type'X'GWB PLUMBING NOTES FACADES,3'MIN.IN DEPTH IF J U a- <br /> u <br /> Fireblocking: Vertically at ceiling&floor levels 1. Showers&kitchen sink faucets shall be rated at Z5 (EMC 19.12.120(A)) <br /> Horizontally at 10'max. gpm flow or less(RCW 19.27.170). 37 SQ.FT.FRONT PORCH ENTRANCE - O <br /> vertical&horizontal void intersections 2. Toilets to be limited to 1.6 gal per flush(RCW ----- <br /> Openings around vents,pipes,ducts,& Lavatory <br /> fa THE MAIN ENTRANCE MUST _ <br /> - wires 3. Lavatory faucets shall be rated at 2.5 gpm Flow or OPEN ONTO AN UNENCLOSED <br /> less(RCW 1 oned 70)at dwelling units less than PORCH THAT IS AT LEAST 36 - <br /> 1,500 conditioned square feet,and shall be rated at -_-- <br /> IRC SECTION R307 1.00 SQ.FT.IN AREA. _ -- <br /> gpm flowor less(Per WSEC table R406.2 option - <br /> Water Closets: 15"from face of wall to 5a)at units larger than 5,000 conditioned square feet. (EMC 19.08.050(B)(2)) <br /> centerline min.,21"front clear 4. Insulation for hot water pipes shall have a minimum _ <br /> floor space min. thermal resistance(R-value)of R-3 per WSEC ONE PRIMARY ENTRANCE MIN. m 2E <br /> R403.5.3. ORIENTED TOWARD STREET, <br /> Lavatories: 21"front clear floor space min. 5. Water heaters shall be secure to framing w/(2)galv. AND AT GRADE <br /> seismic straps. (EMC 19.08.050(B)(3),(C)) <br /> Showers: 24"front clear floor space min. 6. Water heater pressure relief valves shall be plumbed LU <br /> to exterior. <br /> 7. All electric water heaters in unheated spaces or on r<DESIGN STANDARDS-SIDE <br /> IRC SECTION R308 concrete floors shall be placed on an incompressible, 3/32"=1'-0" ,Q o J <br /> insulated surface with a minimum thermal resistance <br /> Safety Glazing When in fixed or operable panels of R-10 per WSEC R403.5.5. _ <br /> required: of doors N Q <br /> When within 24"of door swing O t0 w <br /> When all of the aterthan9 met: MECHANICAL NOTES EVERETT MUNICIPAL CODE ANALYSIS: 3 <br /> pane greater than 9 SF, <br /> bottom below 16"AFF, 1. Source specific fans which vent to building exterior <br /> N <br /> are required as follows: <br /> top more than 36'AFF, baths&powder rooms: <br /> 36" CHAPTER 19.08- O lL U <br /> &walking surface within 50 cfm v.t.o.;min.2.8 cfm/watt efficacy H G LL <br /> laundry room: RESIDENTIAL USES AND DEVELOPMENT <br /> When included in a guard or railing 105 cfm,v.t.o.;min.2.8 cfm/watt efficacy STANDARDS 7 Q <br /> When adjacent to wet surfaces L <br /> When adjacent to a stair,ramp,or kitchen range: U <br /> IL <br /> landing 100 cfm,v.to.;min.2.8 cfm/watt efficacy <br /> CHAPTER 19.08.050 wm <br /> 2. Whole House Ventilation. Installer shall be <br /> IRC SECTION R309 responsible for the design and installation of an FRONT PORCH&ENTRANCE REQUIREMENTS -All public street-facing facades <br /> intermittent whole-house ventilation system include a main entrance that opens onto an unenclosed porch <br /> Garage Floor: Noncombustible material, complying with the requirements as prescribed in <br /> Sloped to drain towards section M1505.4 of the 2018 International Residential <br /> Z vehicle entry doorway Code as amended by Washington State.System CHAPTER 19.12- <br /> shall uFllizewhole house ventilation using exhaust BUILDING FORM AND DESIGN STANDARDS <br /> IRC SECTION R310 fans per section M1505.4.1. <br /> a. System shall provide both manual control and <br /> Emergency Opening not more than 44"AFF automatic control,is.24 hour clock timer <br /> Escape Openings: 5.7 Sq.Ft min b. System shall operate at least two hours out of CHAPTER 19.12.040 <br /> .E 24"Tall,20"Wide opening min. every four. <br /> c. At the time of final inspection automatic A)VERTICAL ARTICULATION-Street-facing front and side elevations include <br /> control shall be set to operate the whole- cantilevers at the 2nd floor and changes in materials to create a distinct'base'and SF�I��I `o <br /> IRC SECTION R311 house fan according to the schedule used to 'middle'; able roof forms tuck into the main roof form to create a distinct'to <br /> calculate the whole house fan sizing. 9 P <br /> Egress door: Min.1 door with 32"clear width d. Installer to provide manufacturer install& It <br /> o Hallways: 3'min.clear width operating instructions Bl HORIZONTAL ARTICULATION-Changes in materials and projecting bays are <br /> t Stairways: T min.clear width+6'-8"clear ht. 3. All exhaust fans shall have a tight fitting back draft utilized to create horizontal articulation,with street facing facades broken into J <br /> 0 7-3/4"riser max.,10"tread min, damper. groupings less than 50'in length. <br /> Handrail 1 side minimum 4. All exhaust openings shall terminate not less than <br /> 3'-0"from operable windows and doors,gravity air C)FACADES LONGER THAN 100'-Vertical and horizontal articulation provided as <br /> IRC SECTION R314 intakes and property lines per section M1504.3 described above. <br /> Smoke Alarms. At every sleeping room, °JOB NO.: <br /> outside sleeping areas and D)BLANK WALL STANDARDS-Street-facing ground floor walls incorporate 22206 <br /> at every story windows,doors,and changes in material pattern and color to mitigate blank walls. <br /> PLOT DATE <br /> nterconnected on line ELECTRICAL NOTES <br /> a <br /> voltage with battery E)EXPOSED FIRE WALL STANDARD-No exposed firewalls are proposed. = 1/17/20243:15:58 PM <br /> backup 1. A minimum of 90 percent of permanently installed <br /> lamps in lighting fixtures shall be high efficacy lamps F)EXTERIOR BUILDING MATERIALS-All cladding will be painted fiber cement DATE: 06/082023 <br /> E IRC SECTION R315 per WSEC R404.1. siding In a varlet of styles,patterns and colors. <br /> 2. Electrical&lighting design provided in these plans 9 Y tY P v SCALE: As Indlceted <br /> Carbon Monoxide Outside sleeping areas are conceptual only. It shall be the sole responsibility <br /> Alarms: and at every story of the Contractor to select fixtures and document CHAPTER 19.12.120 DRAWN: MB <br /> compliance with energy code requirements. -"CHCKD: TM <br /> o FIRE SPRINKLERS: WEATHER PROTECTION-Facades fronting a public street have unenclosed, 3 BLDG. SHEET NO.: <br /> Building to be fully sprinklered per IRC <br /> covered porches that are 3'deep and 8'high per EMC Table 12� <br /> appendix 0,IRC section P2904/NFPA 13d ` A A02 <br /> U <br />
The URL can be used to link to this page
Your browser does not support the video tag.