Laserfiche WebLink
19011 Wood-Sno Road NE,Suite 100 <br /> BTILWoodinville,WA 98072-4436 <br /> Phone:425-814-8448 <br /> IE NGI NEE RIN G Fax:425-821-2120 <br /> Benton Square TH Revision Date: 1/11/2021 <br /> Unit Type 'B' <br /> Redundancy,p ;1.0 ](Section 12.3.4) <br /> Design Base Shear <br /> S MS = F e S s (Eq. 11.4-1) S M 1 = F,,S, (Eq. 11.4-2) <br /> = 1.42 = 0.89 <br /> S Ds = 1/S ms (Eq, 11.4-3) SDI = Y1 S M 1 (Eq. 11.4-4) <br /> = 0.95 = 0.60 <br /> Seismic Design Category: Structure Period and Weight: <br /> Short Period-- D <br /> 1-Second Period-- D Cr = 0.020 Table 12.8-2 <br /> x = 0.75 <br /> Building Height(Mean Roof),h„ = 32 ft <br /> Approximate Fundamental Period, TB = Ct (h„)" (Eq. 12.8-7) <br /> T = Te = 0.27 <br /> TL = 6 (Figs. 22-14 thru 22-17) <br /> Calculated design base shear. <br /> V= C, W (Eq. 12.8-1) <br /> SDs <br /> C s = (TR (Eq. 12.8-2) <br /> CS = 0.15 <br /> The total design base shear need not exceed: <br /> (Eq. 12.8-3) (Eq. 12.8-4) <br /> SD 1 SD 1TL <br /> for T 5 TL CS = T R for T > TL CS = T (TR1 <br /> z <br /> CS = 0.34 CS = 7.53 <br /> Cs = 0.34 T<TL <br /> CS = 0.51 1.5 times Cs in accordance with 11A.8 <br /> The total design base shear shall not be less than: <br /> Cs = 0.044SDSle >_0.01 (Eq. 12.8-5) <br /> Cs = 0.04 <br /> nor where S >_ 0.6g: <br /> C S = 0.5S�/(R/1e} (Eq. 12.8-6) <br /> Cs = 0.00 <br /> CS = 0.15 <br /> V= 0.15W <br /> Date:5/30/2023 <br /> Page: L1.3 g <br />