My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9916 18TH AVE W A 2023 Plans 2025-02-03
>
Address Records
>
18TH AVE W
>
9916
>
Plans
>
9916 18TH AVE W A 2023 Plans 2025-02-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 3:36:09 PM
Creation date
1/24/2025 9:35:15 AM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9916
Unit
A
Permit
B2308-067
Year
2023
Notes
NEW TOWNHOUSE COMMUNITY - BENTON SQUARE BUILDING B, UNIT A
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GRAPHIC SYMBOLS Q Q Q Q Q Q Q o <br /> 4 <br /> DRAWING DRAWING DRAWING Al y <br /> NUMBER---, NUMBER NUMBER <br /> INTERIOR <br /> A11 DETAIL A101 SECTION A2 A701 A4 ELEVATION STREET-FACING FACADES OF RESIDENTIAL BUILDINGS DESIGNED TO LOOK AS a 3 <br /> SHEET SHEET A SERIES OF BUILDINGS NO WIDER THAN 50 FEET EACH(EMC 19.09.020(B)(2)) <br /> I SHEET r J NUMBER NUMBER A3 <br /> 16'-1" l NUMdBrL s 1 _. <br /> Name LEVEL Ro rri name ROOM NAME& DOOR TYPE <br /> Elevation NUMBER <br /> Al REVISION A❑ WINDOW TYPE ® a <br /> APPLICABLE CODES: ACCESSIBILITY REQUIREMENTS: _ o a <br /> ALL CONSTRUCTION SHALL CONFORM TO THE FOLLOWING None applicable per the scoping requirements of the <br /> IE <br /> APPLICABLE CODES®ULATIONS: Federal Fair Housing Act International Building Code <br /> • (IBC).ANSI A117.1 does not establish scoping. <br /> 2018 International Residential Code - - - <br /> •Washington State amendments to the IRC,Chapter 51-51 WAC Section R320.1 of the 2018 IRC defers to IBC chapter 11 - --- <br /> •2018 International Fire Code with statewide amendments for R-3 occupancy; <br /> •2018 Washington State Energy Code IBC1107.6.3 allows reduction of Type B dwelling unit m <br /> •2020 National Electrical Code � T <br /> requirement per section 1107; <br /> •Snohomish County Municipal Code 1107.7.2 exempts multistory dwelling units without <br /> elevator service from Type B requirements. See also <br /> ICC IBC commentary for section 1107.7.2. • c _ - _ - -c . 4 <br /> O r <br /> BUILDING CODE ANALYSIS: <br /> MECHANICAL,PLUMBING 8 Cn En <br /> IRC SECTION R302 ELECTRICAL NOTES. <br /> ll..s. 11'-W 20'-6" Is,-V, <br /> Exterior Walls: 1-HR Rated when<3'separation <br /> GENERAL NOTES PILASTERS PROVIDE HORIZONTAL ARTICULATION AT<25' <br /> Projections: 1-HR Rated underside when Z to<3' 1 Detailed mechanical,plumbing and fire protection (EMC 19.09.020(B)(1)&19.12.040(B)) <br /> separation design&component selection shall be provided by <br /> the mechanical and plumbing contractors on a design- � 312112 N STANDARDS-FRONT <br /> Dwelling Unit Either double wall consisting of(2)1- 3/32"=1'-0" <br /> separation walls: HR rated <br /> d walls OR a 2-HR Rated build basis. Contractors shall be responsible for <br /> Common wall(1-HR if sprinklered)per obtaining any required permits. <br /> IRC R302.2.6 exception 5,no plumbing 2. All appliances and equipment shall be approved by a STREET-FACING FACADES OF RESIDENTIAL BUILDINGS DESIGNED TO LOOK AS A <br /> or ductwork inside party walls,rating nationally recognized testing lab. SERIES OF BUILIDNG NO WIDER THAN 50 FEET EACH(EMC 19.09.020(B)(2)) <br /> I <br /> hall be continuous the full length of 3. All piping and ducting shall be run in concealed <br /> party wall&from foundation to spaces. Provide cleanouts,balancing valves and the W <br /> underside of roof sheathing like in accessible locations. U <br /> 4. HVAC ducts penetrating one-hour rated assemblies <br /> Garage Separation: 20 min.door with self closing device, shall be minimum 26ga galvanized steel. / z <br /> penetrating ductwork shall be 26ga min. 5. Party walls between individual resident units shall not LU <br /> Separation from adjacent space:1/2" contain plumbing or mechanical equipment,ducts or -. Q Q <br /> GWB vents in the cavity of the common wall. �i '� J <br /> Separation from habitable rooms Q <br /> above:5/8"Type'X'GWB PLUMBING NOTES U <br /> Fireblocking: Vertically at ceiling&floor levels 1. Showers&kitchen sink faucets shall be rated at 2.5 0 Horizontally at 10'max. gpm flow or less(RCW 19.27.170). <br /> vertical&horizontal void intersections 2. Toilets to be limited to 1.6 gal per flush(RCW -_ _ U <br /> Openings around vents,pipes,ducts,& Lavatory <br /> fa <br /> wires 3. Lavatory faucets shall be rated at 2.5 gpm flow or <br /> I <br /> ess(RCW 19.27.170)at dwelling units less than - <br /> IRC SECTION R307 500 conditioned square feet,and shall be rated at <br /> 1.00 gpm flowor less(Per WSEC table R406.2 option <br /> Water Closets: 15"from face of wall to 5a)at units larger than 5,000 conditioned square feet --- <br /> centerline min.,. t 21"front clear 4. Insulation for hot water pipes shall have a minimum <br /> • floor space minhermal resistance(R-value)of R-3 per WSEC <br /> R403.5.3. - _ - <br /> Lavatories: 21"front clear floor space min. 5. Water heaters shall be secure to framing w/(2)galy. <br /> seismic straps. <br /> Showers: 24"front clear floor space min. 6. Water heater pressure relief valves shall be plumbed W <br /> to exterior. <br /> 7. All electric water heaters in unheated spaces or on r1 DESIGN STANDARDS-SIDE _ c U <br /> IRC SECTION R308 concrete floors shall be placed on an incompressible, 3/32"=1'0" Q .2J <br /> insulated surface with a minimum thermal resistance C = <br /> Safety Glazing When In fixed or operable panels of R-10 per WSEC R403.5.5. <br /> required: of doors r'!( Ir <br /> When all ofhe"of door swing MECHANICAL NOTES CO <br /> - <br /> When allofthefollowhan9 met: EVERETT MUNICIPAL CODE ANALYSIS: w <br /> pane greater than 9 SF, 1, Source specific fans which vent to building exterior y <br /> bottom below 18"AFF, are required as follows: Z <br /> top more than 36"AFF, baths&powder rooms: O > <br /> &we <br /> surface within p CHAPTER 19.08- W <br /> 36 S0cfmv.l.o.;min.2.8cfm/watt efficacy RESIDENTIAL USES AND DEVELOPMENT 0 <br /> When included in a guard or railing laundry room: o <br /> When adjacent to wet surtaces 105 cfm,v.t.o.;min.2.8 cfm/watt efficacy STANDARDS • Q <br /> When adjacent to a stair,ramp,or kitchen range: Z U d <br /> landing 100 cfm,v.t.o.;min.2.8 cfm/watt efficacy W <br /> CHAPTER 19.08.050 m <br /> 2. Whole House Ventilation. Installer shall be <br /> IRC SECTION R309 responsible for the design and installation of an FRONT PORCH&ENTRANCE REQUIREMENTS -AII public street-facing facades <br /> intermittent whole-house ventilation system include a main entrance that opens onto an unenclosed porch <br /> Garage Floor: Noncombustible material, complying with the requirements as prescribed in <br /> Sloped to drain towards section M1505.4 of the 2018 International Residential <br /> Z vehicle entry doorway Code as amended by Washington State.System CHAPTER 19.12- <br /> shallutilize whole house ilation using exhaust BUILDING FORM AND DESIGN STANDARDS <br /> IRC SECTION R310 fans peSyste on M shall <br /> prov.1. <br /> a a. System shall provide both manual control and <br /> Emergency Opening not more than 44"AFF automatic control,ie.24 hour clock timer <br /> Escape Openings: 5.7 Sq.FA min b. System shall operate at least two hours out of CHAPTER 19.12.040 <br /> 24"Tall,20"Wide opening min. every four. <br /> E c. At the time of final inspection automatic A)VERTICAL ARTICULATION-Street-facing front and side elevations include <br /> control shall be set to operate the whole- v <br /> IRC SECTION R311 house fan according to the schedule used to <br /> cantilevers at the 2nd floor and changes in materials to create a distinct'base'and y <br /> calculate the whole house fan sizing. 'middle';gable roof forms tuck into the main roof form to create a distinct'top. <br /> d. m <br /> Egress door: Min.1 door with 32"clear width Installer 0 ' <br /> ller to instructions <br /> manufacturer install& s <br /> o Hallways: 3'min.clear width operating instructions B)HORIZONTAL ARTICULATION-Changes in materials and projecting bays are o <br /> Stairways: 3'min.clear width+6'-8"clear ht. 3. All exhaust fans shall have a tight fitting back draft utilized to create horizontal articulation,with street facing facades broken into <br /> i 7-34'risermax.,10"tread min. damper. groupings less than 50'in length. <br /> Handrail 1 side minimum 4. All exhaust openings shall terminate not less than <br /> 3'-0"from operable windows and doors,gravity air C)FACADES LONGER THAN 100'-Vertical and horizontal articulation provided as <br /> IRC SECTION R314 intakes and property lines per section Ml504.3 described above. <br /> Smoke Alarms: At every sleeping room, JOB NO.: 22205 <br /> outside sleeping areas and D)BLANK WALL STANDARDS-Street-facing ground floor walls incorporate _- <br /> at every story windows,doors,and changes in material pattern and color to mitigate blank walls. <br /> interconnected on line PLOT DATE <br /> voltage with battery ELECTRICAL NOTES <br /> E)EXPOSED FIRE WALL STANDARD-No exposed firewalls are proposed. 1/17n024 3a s:0a PM <br /> backup 1. A minimum of 90 percent of permanently installed <br /> lamps in lighting fixtures shall be high efficacy lamps F)EXTERIOR BUILDING MATERIALS-All cladding will be painted fiber cement a DATE: 06108/2023 <br /> IRC SECTION R315 per WSEC R404.1. <br /> 2. Electrical&lighting design provided in these plans siding in a variety of styles,patterns and colors. v SCALE: As indicated <br /> - 0 Carbon Monoxide Outside sleeping areas are conceptual only. It shall be the sole responsibility o DRAWN: MB <br /> Alarms: and at every story of the Contractor to select fixtures and document CHAPTER 19.12.120 <br /> _ compliance with energy code requirements. <br /> CHCKD: TM <br /> FIRE SPRINKLERS: WEATHER PROTECTION-Facades fronting a public street have unenclosed, <br /> covered parches that are T deep and 8'high per EMC Table 12-4 '°BLDG. SHEET No.: <br /> m Building I appendix Q,IRC section P2904/NF A 13d <br /> B A02 <br /> U <br />
The URL can be used to link to this page
Your browser does not support the video tag.