My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9502 18TH AVE W 2023 UNIT Q Plans 2025-07-15 (2)
>
Address Records
>
18TH AVE W
>
9502
>
UNIT Q
>
Plans
>
9502 18TH AVE W 2023 UNIT Q Plans 2025-07-15 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2025 8:32:58 AM
Creation date
1/24/2025 11:08:10 AM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9502
Tenant Name
UNIT Q
Permit
B2310-030
Year
2023
Notes
NEW SFR - REF RB2306-005 - UNIT Q
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SLIDING GLASS DOOR <br /> - SELF ADHE51VE PER PLAN <br /> MEMBRANE PAN SLIDING GLASS DOOREXTEND MIN.6'UP JAMB -__-- <br /> FLASHING NAIL FLANGE <br /> NAIL ON FLEXIBLE GALV T FLASHING NERVASTRAL TO EXTEND j \ - <br /> FLASHING 2"MIN FROM TOP OF 2'PAST THE INTERIOR I <br /> FLOOR JOIST LEDGER TO LAG 5CREW STUD----- OF THE DOOR \ HEADER/ IL HEADER/ <br /> PER PLAN— 5/4z4 CEDAR CECKING _�' I I \ / \ / <br /> --' -- PER PLAN WATER-RESISTIVE ROUGH ROUGH <br /> I <br /> N �) OPENING OPENING _ <br /> BARRIER - - / V �� / \ <br /> em+ <br /> 1. 2x PT JOIST PER PLAN <br /> I i JAMB\ JAMB\ � - <br /> i HANGER PER PLAN JOINT FLASHING �\`PIECE .I / SILL \ / SILL <br /> r <br /> _1 INSTALL PLANKS <br /> RIM JOIST IN MODERATE _ A PENETRATION I� <br /> PT LEDGER PER PLAN CONTACT - ----/ l57 PIEC 6' <br /> BUILDING PAPER iv <br /> SHEATHING PER PLAN <br /> INSTALLED BEHIND w/BUILDING PAPER BEHIND IT w/8° / EXTEND 12'BEYOND = OF THEPENETRATION EWES •ATTACH SILL STRIP FLASHING DE MOSTOP OR E0. FLASHING MATERIAL ATTACH_AM8 STRIPS OF 9'W <br /> SIDINa FER <br /> LEDGER AND PANrl�jE�.�E'ID:TALLED <br /> I PER PLAN PLAN WITH E E <br /> FLASHING LAP <br /> OVER HOUSE WRAP I BEFORE SIDING STEP I STEP 2 � <br /> �__... OPENING OF 9'WI ( ) I WIDE M015TOP(OR E0.). <br /> EXPOSED ON ALL 4 SIDES " - THE TOP EDGE EVEN W TN THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EWE EVEN WITH THE JAMB w <br /> - •EXTEND THIS STRIP AT LEAST 12'BEYOND THE EWE OF THE ROUGH OF THE ROUGH OPENING. T <br /> �ZDECK LEDGER DETAIL SIDING BUTT Oir FLASHING ��EXTERIOR DOOR FLASHING WIC PENETRATION PROTECTION ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLES. ABOVE LOWER EWE OF HEADER. <br /> Y�VLL/ N. 55. WI6 SCALE:N.T.S. -.-.- ------- VVIJ SCALE:N.T.S. SCALE:N.T.S. <br /> �/ -- - START JAMB STRIPS 2 BELOW SILL STRIP AND EXTEND b — <br /> cvrtue Tan•wnxaw I Ii_ o CENT.BEAD OF I , <br /> ��st>aa HEAD SEALANT W <br /> UNDER NAIL FIN <br /> sGo PER PLAN 2 <br /> ■ <br /> OPERPBI.E FIXED <br /> PANEL I CUT AWAY <br /> ` WINDOW EXCESS WINDOW !l/ <br /> -' LIVE of FRAME OR BLDG.PAPER FRAME OR I-� ' 1 1 <br /> NERVESTRAL _____ _ _I__________I yd HEARTWOOD CEDAR TRm, SIMILAR III OPENING <br /> SIMILAR L.L_{ <br /> BEHIND ALL SIDES,CAUI.K/SELL <br /> V-b"TO HOSE BIB BOTTOM E0, EQ. OPENING_ OPENING <br /> 5'a' ANDING T P. MOTE: SEAL ALL BUILDING <br /> 3-b'TO SIDING I POUR AGAINST <br /> Cl,OF I I .I NatVl5TRAL EXPOSED FASTENERS BUILDING <br /> PAPER <br /> PRONTO FRONT PORCH0 1 PATIO SHEATHING PER PLAN PAPER TYP. \ <br /> ELECTRICAL 3'-b'LANDING TYP. <br /> BEND METER MAIN @BALK PATIOS �AT w uPx�Iw HLOG pgpER LINE Of BUILDING PAPER TYP. / <br /> a TxE D•m INSULATION NAIL FLANGE UNDER SILL STRIP <br /> ' s<.o.IvtDIweRF?S:BIE PER PLAN <br /> ® PRONTO BEND APPROVED FLASHING - - - -- <br /> FRON 9:6 NFARTYtlOD CEDAR TRIM STEP 3 STEP 4 <br /> INSTALLED ON DOOR - (0.19 x 10'ROLL) •APPLY THE NEXT COUR5E OF BUILDING PAPER BUTTING TO THE <br /> CORN <br /> —� LANDING R PER NL PoUR •APPLY A 3/8"CONTINUOUS BEAD OF CAULK TO THE BACK Of THE FRAME <br /> OF HOUSE --EXT.OF HOUSE THRESHOLD . AGAINST NERVESTRAL s•s HEART.CEDAR SIDING PER PLAN 1-1/2'GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING)OVER THE JAMB FLASHING MATERIAL. �� O <br /> AT GARAGE --- HOSE 30R FELT PAPER - -- - --- --- TRIM,w FLASNING 6 BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE NGISE INTERSECTI cov`J <br /> `j �-BIBS ,,ram% NERVEsrRAL LANDING PER PLAN I MERE OCCURS INSTALLED JAMB AND SILL a JAMB MOISTOP(OR E0.)FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF <br /> STARTER STRIP f - - ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS I/2 PAPER WIDTH. <br /> INSTALL s OF STEPS TTBD BY I ENE OF NERVFSTRAL 30R FELT TO TEND UP •STARTING FROM THE BASE OF THE WALL,,APPLY BUILDING PAPER UNDER <br /> GROUNDING FLASHING— MD 5ILL - 9TE CONDITIONS I <br /> - _- '--" ROD 12°FROM- _- - _ ��__ E - -_ °\ __ WALL 12'MIN,IX •THABOyE THESILL <br /> P ANDD BETWEEN <br /> EXCESS BUILDING PAPER THAT MAY EXTEND "Q <br /> ROD1PRON 'BEND ` cac.wAu THE JAMBS OF THE OPENING. <br /> GUTTER PER ADD FORTIFLASH STICK FLASHING @ BOTH SIDES OF WINDOW > <br /> FORTIFLASH a/FLASHING PLAN—'- `"-- ROOF TRUSS li s¢In°FCR rwrt wx APPLY SLOPED 28 GA..2"HACK, PREFINI5HED METAL FLASHING TO OPENING. 1 L I <br /> AND M015TOP.TURN- 9"MOISTOP --::. L <br /> — .. -° - rlo Dart yawl ct:T,w <br /> ROOF SHEATHING PER PLAN .APPLY 6'FORTIFLA514 OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST <br /> ALLFOR 511LA5N 1"ONTO PANEL, FASCIA PER PLAN JAMB FLASHING 2°. <br /> ALL SIDES a CORNERS. EXT. LANDING DETAIL @ R0.OF TRuss z � <br /> FLASHING FLASHING DETAIL EAVE �� ROOF TO WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS W <br /> x2 TRIM @ PERIMETER TYP. 1 n SLIDING GLASS DOOR TYP <br /> OPENING FOR ELEC. �-00 MIN.BLDG WIS SCALE:N.T.S. WIL SCALE:N.T.S. WII SCALE:N.T.S. NI SCALE:N.T.S. O <br /> METER BOX,FIREPLACE PAPER BEHIND <br /> DIRECT VENT,RANGE VENT, METER MAIN <br /> DRYER VENT,ETC, SEALANT WINDOW FRAME �(1 <br /> 3/5'BEAD CAULK INSULATION 7/I6'PLYWD.SHEATHING 1\1 1 <br /> s SEE DETAIL WICC FOR MOISTOP INSTALL INSTRU❑CTIOkS SILL A55EMBLY SEA (WHERE OCCURS) 6'FORTIFLASH 0/FLASHING <br /> ELECTRIC I IETER It HOSE LJIB PER SPEC TRIM PER ELEVATION _ 4 <br /> GYP.BD. _-. WD.FRAME WALL SIDING PER PLAN <br /> LOCATION NO GAS METER PER PLAN <br /> (WHERE APPLICABLE) INSULATION BUILDING PAPER <br /> 1 ( TRIMMER (WHERE OCCURS) R-10 INSULATION MOISTOP(SEE DETAIL WHO <br /> VVJ SCALE:N.T.S. MOISTOP(SEE DETAIL KING STUD BEHIND HDR,TYP @ FOR I!4"GAP BTWN SIDING <br /> GYP.8D. <br /> WIO FOR INSTALL) WD.FRAME WALL ALL HDR's MIN.I <br /> SEALANT PER PLAN AND FLASHING <br /> 91N.18' EXT WALL PER FORTIFLASH ON AL GYP BD MOISTOP(SEE --FLASHING TURN DOWN PLAN 6"ED BY PACIFIC <br /> Llr <br /> PLAN , - SIDES OF WINDOW DETAIL W10 HEADER PER PLAN <br /> FOR INSTALL 1/I6'PLYWD.SHEATHING 1/4'AT EACH END51DING PER PLAN ) RIDGEHORS.UITE 44 TlLS <br /> IN5ULATION WINDOW FRAME TRIM PER ELEVATION WIT14M PAYMENTOO er LICENSE FEE TO PACIFIC LhIY <br /> WHERE OCCURS) BLDG.PAPER BLDG.PAPER (SEE ELEV.FOR <br /> nLG r'ER TYP. ( SEALANT (WHERE APPLICABLE) RIDGE HOMES. <br /> SIDING PER PLAN WINDOW HT <br /> 10'-6'TO HOSE BIB !DIP vl R PLAN 7/I6°PLYWD.SHEATHING TRIM PER ELEVATION SEALANT <br /> W-6'TO L.L. „ ,D TRIM FORTIFLASH ON ALL PLAN SUMMARY <br /> OF PRONTO BEND _.._r t----- (WHERE APPLICABLE) SIDES OF WINDOW SEALANT WINDOW FRAME moaRslr sc.n. <br /> W-6' 3'-0' 51DING / INSIDE :,;(:'RIVER �1 WINDOW SILL @ WOOD FRAME WALL �1 WINDOW JAMB DETAIL WINDOW HEAD DETAIL N/A <br /> EWE TO EWE TO qq I.In I.ly I.I/ <br /> EWE EWE cLECTRICA- W-I SCALE:N.T.S. VVU SCALE:N.T.S. YV/ SCALE:N.T.S. YV�O SCALE:N.T.S. <br /> METER MAIN 806 <br /> CORER~{ ® PRONTO BEND 0 15 <br /> STUDS P I6'oc(NO P05T5/ <br /> OF HO15E INSTALLED OP; POINT LOAD5 ABOVE VENTS) _ <br /> EXT.OF NGUS= LAP SIDING,U.NO.(HOLD I-V2' I881 <br /> OFF ADJOINING ROOF) <br /> AT GARAG -- LOSE LAG SCREW METAL FLASHING SIDING PER PIAN 424a� <br /> ATTACHED V EO. E0. ✓JJ <br /> GAS (MAY BE STEPPED) M BOTTOM SILL PLATE NM* <br /> METER INSTALL TO h,, .STUDS.LAG ELECTRIC <br /> GROUNDING .IKEr. PENETRATE BUILDING PAPER ON 3/4'TOG SUBFLWR <br /> -ROD 12'FROM ( , "° : i'i FLASHING <br /> ',. _ �fUC r�IN.,TYP,@ SHEATHING SIDING CUT w " '"'"�'r""''"Mtl <br /> PRONTO BEND i. _,I%2/3 HT OF AWAY FOR CLARITY) <br /> FORTIFLASH o/FLASHING FFJI f.',CH w/1 ° 7-I/2"xl5-I/2'CEDAR RIM JWA <br /> AND MOISTOP.TURN �-9"r1O5TOP ,. STRAP MIN METAL RAIN DIVERTER(THE I BTL ENGINEERING <br /> w II VENTS w/GALV SCREEN- <br /> FORTIFLASH I"ONTO PANEL, PURPOSE 15 TO SHED THE PROVIDE LOUVERED VENTS a•roas <br /> ALL SIDES a LONTO P _ _, �HOOT WATER OFF THE ROOF AND ROOF SHINGLES @ FRONT ELEVATIONS <br /> (LASHING KEEP IT AWAY FROM THE / PER SPEC. RIM PER PLAN SEE REVVV15ION LOG <br /> &2 TRIM @ PERIMETER np VERTICAL WALL BENEATH). P.T.MUD SILL <br /> 304 ROOF FELT SCALE:y°=1'-0' <br /> OPENING FOR ELEC. 60 MIN.BLDG :'j OF NWT FASCIA PER PLAN w/ / CONCRETE FOUNDATION seT ronena <br /> METER BOX.,FIREPLACE PAPER BEHIND GUTTER <br /> DIRECT VENT,RANGE VENT, METER MAIN 7A6"055 ROOF --DO NOT INSTALL VENT(S)CLOSER THAN 3'TO GAS METER,, WATER <br /> DRYER VENT, ETC. SHEATHING $$BUILDING PAPER SHOULD BE INSTALLED OVER FLASHINGss INTRU5M <br /> NOTE:PER WSEC R4022.7:WHEN FOUNDATION VENTS ARE NOT PLACED`50 TWAT THE TOP DETAILS <br /> s SEE DETAIL WIO FOR MOISTOP INSTALL INSTRUCTIONS . . OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO <br /> ELECTRIC t GAS METER, HOSE USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOVER SURFACE OF THE FLOOR INSULATION. <br /> BIB CLEARANCES $ LOCATIONS CATER NEATER (NWT) STRAPS DETAIL @RODE/WALL INTERSECTION / FOUNDATION VENT1 <br /> � VL� , YII f� <br /> W5 SCALE:N.T.5. SCALE:N.T.S. Yam/ SCALE:N.T.S. �VJ SCALE:N.T.S. <br />
The URL can be used to link to this page
Your browser does not support the video tag.