FLOOR PLAN NOTES ` <br /> I, CONTRACTOR SHALL VERIFY ALL NOTE5,MATERIALS t CONDITIONS PRIOR TO <br /> CONSTRUCTION. <br /> McIF1O4 '"�;Y - <br /> WINDOWS $ DOORS: 'follow. , <br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/R-10 INSULATION. <br /> 3. WINDOWS f DOORS ARE SHOWN t NOTED AS NOMINAL SIZES. I" •`+ <br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. -EGRESS WINDOW SILL HEIGHT R.O.@ <br /> w <br /> MAX.42'A.F.F. c� <br /> 5. ALL WOOD IN CONTACT WITH CONC,TO BE PRESSURE TREATED. <br /> - <br /> b. EXTERIOR WALLS TO BE 26 STUDS @ 16'O.C.,U.NO. <br /> 7. GARAGE DOOR HEADERS @ 84'A.F.F. 0 <br /> 8. EXTERIOR SWING DOOR HEADERS @ 83 1/2'A.F.F. <br /> q. INTERIOR SWING DOOR HEADERS @ 83'A.F.F. <br /> 10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS QR BE 3'MIN.ON HINGE SIDE, 15'-2Xt' 8'-3V�' 614' <br /> I1. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD Ob'THICK 20-MINUTE FIRE-RATED DOOR <br /> w/A SELF CLOSING HARDWARE DEVICE. 4'-7Y4' 0-0" 4'-7Y" 2'-0' 5' <br /> 12, PER R311.3.1+THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOOR5 1-1 <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4'BELOW THE TOP OF THE <br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR T <br /> 13. ALL 81-FOLD t BI-PASS DOORS TO BE CENTERED,U.N.O. --1- <br /> AFR MING: CC1 <br /> 14. VERIFY FIREPLACE STYLE t LOCATION V SUPERVISOR PRIOR TO CONST. 6046 XO 2030 XO <br /> I6. FRAMERS TO INSTALL ALL WINDOWS t INTERIOR COLUMNS (EGRESS) (OBS) O <br /> Ib. TOWEL RING BLK'G @ 57'A.F.F. <br /> 17. TOWEL BAR BLK'G @ 48'A.F.F.t BLOCK BOTH BAYS. T -e W/5(I) w \ <br /> 18, TOILET PAPER HOLDER BLK'G @ 22'A.F.F.AND 42'FROM BACK WALL WHERE POSSIBLE .17 -------- `l <br /> 19. THERMOSTAT BLK'G @ 60'A.F.F <br /> 20, EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'5 SHALL BE INSTALLED AT T-6'A.F.F. 60'VANITY ro <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE <br /> GARAGE DOOR TRIM T2 668 BATH I <br /> 22. ADD CONT.BLOCKING FOR STAIR HANDRAIL BRACKET5 tPr <br /> CPT 77 5F <br /> BEDROOM I us Q <br /> 23. STAIRS w/WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL INSTALLED ON 36"z80 GWB <br /> THE INSIDE OF THE STAIR'.RUN 13i x14 4 FIN1514ED <br /> 24. LADDER-BLOCK AT EXTERIOR WALL5 AS NECE55AR FOR INSULATION INSTALL ° OPENING -� <br /> TB 2 _ <br /> VENTILATION: <br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL EXHAUST FAN IN <br /> ACCORDANCE WITH M1505.4.1.1. 4'-5' <br /> 26. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY. (TO FACE OF RISER) <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(1).EXAMPLE:70 CFM FOR 2600 0 <br /> - z <br /> SF HOME w/4 BEDROOMS,AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE 3-� ----- = WHOLE W <br /> MIE05.4.3(2)TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED VENTILATION SYSTEM. -- HOUSE <br /> 28. WHOLE HOUSE FAN SHALL BE 1.0 SONES OR LESS,AND 5HAL.L.HAVE AN EFFICACY OF 2.8 MINI-SPLIT q_r��� FAN r\ O <br /> CFM/WATT PER W5EC R403.6.1. 2zb WALL - 22"z30" CPT U ILITY - <br /> 29. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOWS PER STATE ' " 9D/® ATTIC sq HS 2868 - S'3Xq'] VTO�i 1 Y <br /> CODE INTERPRETATION N7AN ACCESS 2zb WALL L <br /> 30, PROVIDE U FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE DN :0 5'-q' <br /> WHOLE HOUSE FAN. 31_6 15R,14T q_p MINI-SPLIT \ <br /> 31. PER IRC M1502.4.5.:WHERE THE DRYER VENT EX14AJ51 DUCT 15 CONCEALED WITHIN THE Z. l <br /> BF <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE 50'H I/2 WALL § °'�-4" _ �� I 1 1 IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED " _4 5,-V" W/5(3) - I'-0" ^ <br /> WITHIN 6FT OF THE EXHAUST DUCT CONNECTION. ----.- 3'_1 42'H HALF <br /> WALL <br /> LIFE SAFETY: a OPEN TO 266E us�� <br /> x Z �u <br /> - 26, A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPERATURES AND `.� Sv 4 g O <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. BELOW `� BEDROOM 2 ? b <br /> S 27. THE NEAT ALARM OR NEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE g z STAIRS w/ Tp BAT I <br /> ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROOM OR 3�_6 WINDER STEPS 5'Oxq'll q'7x132 _ <br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION DOUBLE RIM OR ' WILL ALWAYS?8'H HAVE A �', <br /> 10. SMOKE DETECTORS TO BE IIOV, INTERCONNECTED, w/EATERY BACKUP<CENTRALLY PROVIDE SPLICE " I/2 WALL CONTINUOUS b w <br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE 12 - <br /> INSTALLED WHERE THERE 15 A CEILING HEIG14T CHANGE GREATER THAN 24 3$ ur INSTALLED IL TB Q 4-0 BF m <br /> 11. SMOKE DETECTORS SHALL BE INSTALLED QLLE`555 THAN 3 FT HORIZONTALLY FROM THE = THE 11�JS pg OF SO/CO SO <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER.M141 bu THE STAIR RUN 60'z32' �. <br /> 12, IONIZATION SMOKE ALARMS: °TUB/SHWR 2668 ----W%g(�) --- <br /> < SHALL NOT BE INSTALLED LE55 THAN 20 FT HORIZONTALLY FROM A PERMANENTLY 2z ALL <br /> INSTALLED COOKING APPLIANCE. ADD FLAT <br /> z IONIZATION SMOKE ALARMS WITH AN ALARM-51LENCING SWITCH SHALL NOT BE INSTALLED 2X4 THROUGH g V-6" 2668 MI I-SPLIT <br /> LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. nz6+ T-�" 5'-' 4'- -10'§' <br /> 24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FT JOIST @ 5'O.C. <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE CR3141 rn D COPYRIGHT NOTICE:THIS <br /> 25,GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH I/2'G.W.B.d 5/8" PLAN 15 AWNED BY PAGFlC <br /> " r QSD RODE Hn'tEs.USE of THIS <br /> TYPE'X'ON THE CEILING.POLY SEAL RIM, ENTIRE GARAGE TO MEET JURISDICTION " m"' PLAN I5 PROHIBITEO Br IAw <br /> DRAFT STOP REQUIREMENTS ' ' wlrucuT PAYMENT OF <br /> LICENSE FEE TO PACIFIC <br /> 26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE FR07ECTED WITH Yz'GWB AT THE , T N BEDROOM A i t RIDGE NGMES. <br /> WALLS, UNDER-STAIR SURFACES AND SOFFITS. b z i BEDROOM 3 <br /> STT HR5416Z. - 10'4xll'4 '^ ^' q'7xll'lO' <br /> 27, PROVIDE FIRESLOCKING PER PLAN AND @ ALL PLUMBING PENETRATIONS. SECTION THRU '� I- -1 - <br /> AATTACH TO ne _ PLAN SUMMARY <br /> 2X AND TO WALL CAP - aweon ea n, <br /> TAIR RIM i N/A <br /> 80G <br /> y 704E XOX(EGRESS) 1075 u <br /> w/GRID PER ELEV. <br /> HALF WALL FRAMING I CAP DETAIL 4040XO - 1851 <br /> UI•] SCALE:1/2'-1-0" LINE <br /> OF W (EGRESS) <br /> WA 424 m� <br /> PER ELEV. <br /> ELECTRIC <br /> -PROVIDE MIN.30' ATTIC ACCESS B LT ENGINEERING <br /> HEADROOI CLEARANCE. SHEATHING ON <br /> -TRUSSES U01 BE OUTSIDE OF 2'-7)¢' T-0' 2,-7" <br /> INSTALLED @ 24"O.C. TRUSS MEMBERS SEE <br /> "SEE <br /> REVISION LOG <br /> O0 12'-2Y 2'-7' I'-10' 3'-3" 4'-0'__ 3'-31 -••uxa, <br /> -- SCALE:Y" <br /> 2'-10YV I6.411 10'-b" wrt ALE.e, <br /> UPPER FLOOR PLAN <br /> 5/4 TRIM GWB ATTIC <br /> OR SIM. ACCESS LID <br /> � ATTIC ACCESS DETAIL UPPER FLOOR PLAN - 'A' $ 'B' EL_EV's j }' <br /> SCALE:1/2'•I'-0' SCALE: 1/4'-1'-0' to <br /> ('A' 4 'B' ELEV's) <br />