9918 18TH AVE W C 2023 Plans 2025-02-03
>
Address Records
>
18TH AVE W
>
9918
>
Plans
>
9918 18TH AVE W C 2023 Plans 2025-02-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 9:50:19 AM
Creation date
1/24/2025 2:06:22 PM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9918
Unit
C
Permit
B2308-076
Year
2023
Notes
NEW TOWNHOUSE COMMUNITY - BENTON SQUARE BUILDIN C, UNIT C
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1-HR FIRE-RATED PARTY <br /> WALL CONSTRUCTION <br /> NON-FINTERIOR <br /> RE RATED G.L. NO ROOF PENETRATIONS WITHIN 48"OF FIRE <br /> INTERIOR STAIR RATED PARTY WALL ROOF SHEATHING SHALL G.L. o <br /> CONSTRUCTION BE APPROVED FIRE-RETARDANT-TREATED TYP,NON-RATED ROOF- NO ROOF PENETRATIONS WITHIN 48"OF FIRE <br /> WOOD WITHIN 48"OF FIRE-RATED PARTY WALL CEILING ASSEMBLY RATED PARTY WALL ROOF SHEATHING SHALL ` <br /> BE APPROVED FIRE-RETARDANT-TREATED <br /> I WOOD WITHIN 48"OF FIRE-RATED PARTY WALL <br /> ER/LANDING <br /> FRAMING <br /> I Q <br /> ` 3 <br /> FRAMING CONT.NON-VENTED <br /> PLAN VIEW I TYP.NON RATED BLOCKING AT 1•HR RATED EXTERIOR FACE CLADDING <br /> ROOF-CEILING UNDERSIDE OF EAVE PER ELEVATIONS <br /> ASSEMBLY WP5512 OR U.L#V340 <br /> i-HR RATED PARTY WALL a <br /> ASSEMBLY PER GA FILE to <br /> FIRE PROTECTION LAYER,2": NO.WP-12 zN FIRE BLOCKING PARALLEL PER AWC TR-10: I EXTERIOR GYP I I ❑ 0 WITH SLOPED ROOF LINE <br /> 3 <br /> AT STAIRS&LANDINGS "'THAT BUTT INTO 1-HR I / I SHEATHING PRODUCTS- <br /> RATED WALL tp=[60 1 +�11�3+17] FIRE TAPING AND <br /> CONSTRUCTION,HOLD WOOD VE . . " .STRUCT.BEARING \ / FASTENER HEAD <br /> STRINGER&LANDING RT WEB 25 MIN PROTECTION IS NOT <br /> FRAMING BACK TO ALLOW =72 MINUTES I REQU > <br /> GWB TO RUN IRED PER GA$00 <br /> EXPLANATORY NOTE#B 1-HR RATED PARTY WALL <br /> NOTE TO FLOOR TR CCIIPPIIFR- a coNrlNuous ALL FLOOR TRUSSES PERPENDICULAR TO AND 2 2 1 @ AS.WP5512 I SEMBLY PER GA FILE _ <br /> > <br /> BEARING PARTY WALL FRAMING,SHALL BE I DENS GLASS AT AT <br /> aN PROVIDED <br /> NO. <br /> WITH END VERTICAL WEBS 1 4 4 <br /> COMPRIMISED OF 3 PLIES 2X4 WOOD MINIMUM. GWB•OSB OR2X FIRESTOPPING o LE®10 ` <br /> 1 NON RATED STAIR/WALL AT PARTY WALL 2X NOM.NAILER <br /> I = 4' <br /> I w - <br /> GA FILE NO.WPM FLAT CHORD WOOD I 5/4'W"NOM.WD. _ <br /> 5/8-TYPE X'GWB TRUSS FIRE-BLOCKING <br /> > <br /> Reference 23th edition Gypsum Association Fire Resistance Design Manual CKING <br /> = �~ <br /> FIRE RESISTANCE RATING:1HR LOAD-BEARING PLAN VI L� <br /> __-_ <br /> I ASSEMBLY DESCRIPTION, 5/8"1-HR FIRE-CAULK <br /> GYPSUM WALLBOARD,WOOD STUDS PER U.L.W-L-0040 GWB•OSB OR ZX FIRESTOPPING®10'One layer 5/8"type X plain or predecorated gypsum wallboard,water-resistant (HILTI)CR W-L-0031 / <br /> board,or gypsum veneer base applied parallel or at right angles to each side of 2 x 4 Wood studs (3M)ALL SIDES _16"o.c.with 6d coated nails,1-7/8"long,0.0915"shankd,1/4"heads,7"o.c.Joints of square edge, PROVIDE 5/4'k4"NOM.WD. PLAN VIEW <br /> bevel edge or predecorated wallboard may be left exposed. FROVID CKING AT N MORE OT <br /> Joints staggered 16"on opposite sides.(LOAD-BEARING) THAN 10'INTERVALS 2X NOM.NAILER <br /> HORIZONTALLY - 5/4'k4"NOM.WD. <br /> FIRE-BLOCKING <br /> - TYP.NON RATED ROOF- <br /> CEILING ASSEMBLY <br /> 1•HR RATED PARTY WALL Z <br /> 1-HR FIRE <br /> ASSEMBLY PER GA FILE 1-HR RATED PARTY WALL Z O <br /> PARTY WALL 3" <br /> 3 PROCTECTION- L NO.WP5512 I ASSEMBLY PER GA FILE Q <br /> =1'-0"1 LAYER OF 5/8"TYPE'X'GYPSUM SHEATHING TYP.NONRATED FLOOR- NO.WP5512CEILING ASSEMBLY <br /> 5/4'14"NOM.WD.FIRE- V STRUCTURAL SHEATHING PLAN VIEW BLOCKING AL EACH m <br /> (1)LAYER 5/8"TYPE'X'GYPSUM SHEATHING G•L• C w 2x6 FRAMING SPACING PER 1 �• <br /> STRUCTURAL,NOT TO EXCEED 76"O.C. I 12" TYP.NON-RATED FLOOR- <br /> Q3" CEILING ASSEMBLY w Z <br /> 1-HR FIRE-RATED PARTY O <br /> NON-F <br /> WALL CONSTRUCTION-----.-- <br /> INTERI RE RATED PROVIDE 5/4"x4"NOM.WD. <br /> INTERIOR WALL FIREBLOCKING AT NOT e <br /> META COPING <br /> PREFINISHED CONSTRUCTION MORE THAN 10'INTERVALS <br /> METAL COPING CAP - HORIZONTALLY <br /> RE TYP NON-RATED FLOOR <br /> HI-TEMP SELF-ADHERING CEILING ASSEMBLY <br /> RESILIENT FLASHING 1-HR RATED PARTY WALL <br /> , ASSEMBLY PER GA FILE LAP <br /> OVER W.R.B.BOTH SIDES NO.WP5512 `- <br /> T.O.WALL SLOPES FROM <br /> A <br /> 1-HR RATED PARTY WALL <br /> +6 " LIVING ASSEMBLY PER GA FILE w <br /> ABOVE 2ND FLOOR TO -.- <br /> +6'-0"ABOVE 2ND FLOOR ��1x WD.NAILER EACH SIDE AT WALLS THAT BUTT NO.WP5512 <br /> PLAN VIEW C (,FOR COPING CLEATS INTO TRU RATED WALL EXTENDED 5/8"TYPE'X'GWB ID CONSTRUCTION,HOLD AT EACH JOIST BAY TO LIVING J <br /> STUDS&PLATES BACK TO I UNDERSIDE OF FLOOR LIVING <br /> ALLOW GWB 70 RUN SHEATHING,FIT TIGHT TYP,NON-RATED FLOOR- L = <br /> 4 CONTINUOUS - AGAINSTPENETRATING CEILING ASSEMBLY <br /> FLOOR JOISTS.FIRE CAULK A 2X NOM.NAILER EACH PENETRATION JOINT I ?� <br /> 5MN4"NOM.WD. I PERIMETER,7YP. 6 5/4"x4"NOM.WD.FIRECo- <br /> GUARD MOUNTED ALUM. FIRE-BLOCKING 0 <br /> POWDGUARD RAILING, 5/4'k4"NOM.WD.FIRE-BLOCKING AT EACH FLOOR N I BLOCKING AT EACH <br /> z FINISH COATED LEVEL TYP.NON-RATED FLOOR- FLOOR LEVEL 7 <br /> FINISH I CEILING ASSEMBLY ` j <br /> �a <br /> W ca <br /> I O U <br /> TENSION ND NON-RATED DECK N RATED WAL LP _ <br /> 4, ERP.TO PARTY WgLL �. `O LL <br /> TENSION TIE AT TOP OVER-FRAMING PARTYWALL I ADDITIONAL 2xq 6 U <br /> 3"=1'-0" 5 TYP.NON-RATED FLOOR- _h BOLTED CONNECTION 314"=V-0" CEILING ASSEMBLY a <br /> VERTICAL AT U <br /> FOR FACE MOUNTED TRUSS END w <br /> ALUM.RAILING POSTS <br /> TRUSS BLOCKING SECON 9F W <br /> 114 PER STRUCT. <br /> 5/4" ADDITIONAL 2X4 VERT.WEB AT <br /> DECKING <br /> COMPOSITE OWJ END <br /> a - - I <br /> ° I EXTENDED 518"TYPE'X'GWB AT <br /> TRUSS BLOCKNG PER STRUCT. m GARAGE/ EACH JOIST BAY TO UNDERSIDE OF <br /> FLOOR SHEATHING,FIT TIGHT <br /> ° PROVIDE SADDLE _ ., <br /> FLASHING AT TOP-OF- CLADDING PER 1-HR FIRE-RATED PARTY """ _ ENTRY AGAINST PENETRATING FLOOR <br /> BEAM TO CLADDING ELEVATION KEYNOTES- WALL CONSTRUCTION JOISTS.FIRE CAULK EACH <br /> m CONNECTION _ PENETRATION JOINT PERIMETER, <br /> " -� NON-RATED FINISH LAYER TYP <br /> DECK BEAM&JOISTS GYPSUM WALL BOARD, GARAGE/ <br /> PER STRUCTURAL SHIM AS NECESSARY PLAN VIEW ENTRY GARAGE/ENTRY <br /> E CLADDING PER ELEVATIONS y <br /> — <br /> OVER WEATHER <br /> i-HR RATED PARTY WALL d <br /> r BARRIER SECURE NAILING FLANGE FIRE 1-HR RATED PARTY WALL ASSEMBLY PER GA FILE APER MANUFACTURER'S CAULK ASSEMBLY PER GA FILE STEP HEIGHTS PER I NO.WP5512 m O N <br /> o WEATHER BARRIER,ER, RECOMMENDATIONS PERIMETER, I NO.WP5512 PLANS& LEVATIONS ,v _ <br /> GAF RATED WALL ASSEMBLY PER UPPER COURSE LAP i TYP. PROVIDE ADDITIONAL 1-1/2"XPS <br /> m <br /> I GA FILE NO.WP3605(SEE ABOVE) OVER FLASHING--\ / INSULATION AT VOID&3-V2"XPS <br /> FIBERGLASS TUB OR P.T.PLATE W/ _ _ �r INSULATION AT WALL CAVITY UP TO ADJ. <br /> --P.7.PLATE WITH ANCHOR BOLTS SHOWER ENCLOSURE 1 ANCHOR BOLTS FLSULATI E WHEN ADJACENT TO a <br /> 6 " <br /> `o PER STRUCTURAL LAP W.R.B.OVER BASE PER STRUCTURAL CONDITIONED SPACE TO ACHIEVE R21 MIN.— I <br /> � I <br /> / FLASHING CONT.24 GA.MIN. I r---- <br /> ° _FIR_ST FLOOR PREFINISHED \ ANCHOR BOLTS <br /> W, <br /> a <br /> w` FLASHING - THROUGH,WALL II -.---. _____ PER STRUCTURAL ":JOB NO.: <br /> 0'-0" FLASHING,1/2" GYPSUM WALLBOARD ---- -- -_.--- -- <br /> m SEALANT --- - 22205 <br /> _ MIN.AIRGAP REQUIRED BY RATED WALL ` - <br /> BE7WEEN -_ ASSEMBLY PT RUN ' PLOT DATE <br /> FOOTING&STEMWALL FLASHING 8 UNINTERRUPTED BEHIND ALL 1" 1/2 - <br /> E PER STRUCTURAL CLADDING-- / ADJACENT FIBERGLASS TUB 8 PER STRUCT. --{-- 1/17/20243:17:53 PM <br /> -/ 7/2"GAP MIN._// SHOWER ENCLOSURES 1. <br /> o° FIBER CEMENT SOFFIT W/2 XPS OI INSULATION C.I.P.4 CONC.SLAB <br /> .UPTURNED AT PERIMETER W/2"XPS INSULATION DATE: 06/08/2023 <br /> ° a �' ,AND CONTINUOUS UNDER r UPTURNED AT PERIMETER <br /> y SLAB(CONDITIONED c� PER STRUCT. AND CONTINUOUS UNDER SCALE: As Indicatetl <br /> LOCATIONS ONLY)OVER u, ¢ - SLAB(CONDITIONED DRAWN: MIS <br /> 12 COMPACTED FILWAPOR y LOCATIONS ONLY)OVER <br /> a - PER BARRIER PER STRUCTURAL COMPACTED FILUVAPOR -CHCKD: TM <br /> STRUCT. 8 GEOTECH BARRIER PER STRUCTURAL GENERAL SHEETS <br /> rf DECK PARTY WALL/PRIVACY WALL __ G CLADDING-CANTELIVER SOFFIT 8 TRIM RECOMMENDATIONS PER &GEOTECH. .{ i SHEET AL <br /> oOWER RATED PARTY WALL TYP PARTY WALL NO STEP STRUCT. RECOMMENDATIONS ^ <br /> 8 3/4"=1'-0" 9 �P PARTY WALL STEPPED A�0 <br />