Laserfiche WebLink
SLIDING GLA55 DOOR <br /> SELF ADHESIVE PER PLAN <br /> MEMBRANE PAN SLIDING GLASS DOOR EXTEND MIN.b'UP JAMB -=- <br /> FLASHING- - / NAIL FLANGE <br /> NAIL ON FLEXIBLE f GALV'Z'FLASHING NERVASTRAL TO EXTEND <br /> 2'PAST THE INTERIOR <br /> FLASHING 2"MIN FROM TOP OF <br /> OF THE DOOR HEADER/ HEADER/ <br /> FLOOR JOIST �� `, J / LEDGER TO LAG:CREW STUD <br /> PER PLAN / 5/4x4 CEDAR DECKING <br /> ROUGH ROUGH <br /> - PER PLAN WATER R, , '�I III OPENING OPENING <br /> BARRIER <br /> -2x P7 JOIST PER <,i! <br /> JAMB JAMB <br /> • Pf E / SILL \ <br /> �A' NANGEk PER PLAPi � EC � ' - / SILL A '- <br /> RIM JOIST IN MO <br /> PT LEDGER PER PL-., CONTACT /57 PI PENETRATION <br /> DERATE _ <br /> SILL <br /> BUILDING PAPER rSHEATHING PER PLAN 12' FLASHING <br /> / MIN.12'BEYOND ALL EDGES <br /> INSTALLED BEHIND / SIDING PER / _ BUILDING PAPER TO EXTEND <br /> Ii <br /> LEDGER AND PAN �51DING PER PLAN PLAN-----{ <br /> FLASHING LAP 1_ - , �' I .. - -.., _ � <br /> OVER HOUSE NRAP +LEDGER INSTALLED BEFORE 5046 STEP I STEP 2 Q <br /> EXTEND 12'BEYOND `y OF THE PENETRATION <br /> w/BUILDING PAPER BEHIND T n;/8" I •ATTACH SILL STRIP OF 9'WIDE MOISTOP(OR'c0.)FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9"WIDE MOISTOP(OR E0.). <br /> EXPOSED ON ALL 4 SIDES L__-__..___1 OPENING WITH THE TOP EWE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH IN51DE EDGE EVEN WITH THE JAMB }— w <br /> ' I' •EXTEND THIS STRIP AT LEAST 12'BEYOND THE EWE OF THE ROUGH OF THE ROUGH OPENING. T <br /> �\ DECK LEDGER DETAIL SIDINU BU JV I FLASHING OPENING. START JAMB STRIPS F BELOW SILL STRIP AND EXTEND <br /> I/ ln�ll EXTERIOR DOOR FLASHING PENETRATION PROTECTION ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLES. ABOVE LOWER EWE OF HEADER. t 1T <br /> VVLL SCALE:N f.5. W15 SCALE:N.T.S. Wl4 SCALE:N.T.S. `.JCID <br /> N.T.S. <br /> mart oux+ CONT.BEAD OF <br /> sa:of�OFR HEAD — SEALANT LU v <br /> EO. EO. FLASHING UNDER NAIL FIN <br /> SGD PER PUN <br /> 2 2 v <br /> LOPERABLE FIXED CUT AWAY ■ <br /> PANEL PANEL <br /> LINE OP _ 1"PIMEN11:4 <br /> EXCESS WINDOW /l/ERVESTRAL ______ ___I_________ 2x6 HEARTWOOD CEDAR TRIM, I,. ONSMILAR '� LL.1 OP <br /> BEHIND 1 ED.ALL SIDES,CAUWSFALS'-b'TO NOSE BIB ECJ. -#^ , EO OPENING <br /> i 3'6'TO SIINGBOTTOM OF I LANDING GDI TYP. #NOTE: SEAL ALL III —_J- BUILDING <br /> L.L.OF NE',AS EXPOSED FASTENERS BUILDING PAPER <br /> PRONTO I FRONT PORCH PATIO I I PAPER TYP. <br /> BRD ELECTRICAL V-0 LANDING TYP. SHEATHING PER PLAN TYP. li <br /> snl rATa.saw ururs LINE OF BUILDING PAPER <br /> a Bzvso ix"e nwerzN INSULATION <br /> aF Ta Fam SOE a rxe UNDER SILL STRIP <br /> METER MAIN III BALK PATIds BLW PAPER NAIL FLANGE- 'I <br /> ®I s.c.o.rueleveR self PER PLAN APPROVED FLASHING <br /> WD - - -- <br /> PRONTO BEND 2x6 HEARTW CEDAR TRIM <br /> 019 z 10'ROLL) STEP 3 STEP 4 z <br /> FRONT ^INSTALLED ON DOOR •APPL7 A 3/B"CONTINUOUS BEAD OF CAULK TO THE BACK Of THE FRAME •APPLY THE NUT COURSE OF BUILDING PAPER(BUTTING TO THE <br /> En,OF CORNER LANDING PER PLAN.POUR (. <br /> OF HOI,SE j H01J„E THREHbIx D AGAINST NERVESTRAL 26 NEARTHOCO CEDAR SIDING PER PLAN 1-1/2'GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING)OVER THE JAMB FLASHING MATERIAL. �� O <br /> _ 30u FELT PAPER -- ---------- - TRIM a FLASHING R STWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE ..r\ <br /> AT GARAGE HOSE '� CC) <br /> NERVESTRAL HOUSE INTERSECTION, <br /> ®" BIBB LANDING PER PLAN _ _ WHERE OCCURS INSTALLED JAMB AND SILL t JAMB MOISTOP(OR E0.)FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF <br /> STARTER STRIP ✓yam .(MIN Mar TYP.) I ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH. <br /> INSTALL 4 OF STEPS T'Bp BY I LINE OF NERVESTRAL •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER <br /> GROUNDING .)*' CIII-__ slu L - srt€uTIDM�ON GCE F� \_ 30R FELT TO EXTEND UP ABOVE THE SILLAND BE <br /> —�- -ROD 12"FROM ._ - �� - WALL 12'MIN ANY EXCESS BUILDING PAPER THAT MAY EXTEND 'V^ <br /> FLASHING— " THE SILL STRIP AND CUT <br /> PRONTO BEND BETWEEN THE JAMBS OF THE OPENING. <br /> GUTTER PER D ORT LASH TICK FLASHING P BOTH SIDES Of WINDOW > <br /> FORTIFLASH o/FLASHING -q°1101STOF PLAN--- + �i, ROOF TRUSS II ,III I,,.,,, uo Mrcrr ram onus APPLY SLOPED 28 GA..2"BALK,PREFINISHED METAL FLASHING TO OPENING. �i 1 • 1 <br /> AND MOISTOP.TURN—� _ ROOF SHEATHING PER PLAN •APPLY 6"FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST l--L-1 <br /> SH I"ONTO PANEL, _ FASCIA PER PLAN- EXT. LANDING DETAIL @ ROOF TRUSS JAMB FLASHING 2°. <br /> ALLFOR SIDE <br /> ALL SIDES t CORNERS. <br /> FLASHING FLASHIJWG DEf.., P EAVE SLIDING GLASS DOOR TYP ROOF TO WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS <br /> 2x2 TRIM @'PERIMETER TYP. O <br /> W13 .__.__ W12 WIl VVIV <br /> OPENING FOR ELEC. -60 MIN.BLLti SCALE.N.T.S, SCALE:N.T.B. SCPLE:N.T.S. SCALE:N.T.S. <br /> METER BOX,FIREPLACE PAPER BEHIND <br /> DIRECT VENT, RANGE VENT, METER MAIN SEALANT <br /> DRYER VENT, ETC, WINDOW FRAME 7/16'PLYWD.SHEATHING y u p 0 A 1 <br /> 3/5'BEAD CAULK INSULATION L o u <br /> +SEE DETAIL WIO FOR M01510P INSTALL IH5fRUC"i JU E SILL ASSEMBLY (WHERE OCCURS) 6"FOR1"IFLA514 0/FLASHING p <br /> PER SPECSEALANT ELECTRIC METER It NOSE BIB — TRIM PER ELEVATION T <br /> GYP.BD. WD,FRAME WALL SIDING PER PLAN Q_ <br /> LOCATION (NO GAS METER) PER PLAN <br /> (WHERE APPLICABLE) INSULATION BUILDING PAPER <br /> (WHERE OCCURS) MOISTOP(SEE DETAIL WIIO ' <br /> C= - TRIMMER I R-10 INSULATION <br /> W�, SCALE:NT.5. MOISTOP(SEE DETAIL BEHIND HDR,TYP P FOR INSTALL) <br /> GYP.BD. KING STUD MIN.1/4'GAP BTWN SIDING <br /> WIO FOR INSTALL) NO.FRAME WALL ALL NDR's <br /> - SEALANT PER PLAN <br /> 11N,IB' EXT WALL PER <br /> FORTIFLASH ON ALL GYP.BD. AND FLASHING <br /> PLAN ---- SIDES OF WINDOW MOISTOP(SEE FLASHING TURN DOWN %i PLAN 1i10WNED BY PACIFIC <br /> I DETAIL WIO 7A6'PLYWD.SHEATHING HEADER PER PLAN /4"AT EACH END RIDGE HOMES.USE OF THIS <br /> -- - SIDING PER PLAN FOR INSTALL) —�- / PLAN Is PROHIBITED BY I Aw <br /> PLAN 15 PAYMENT OF <br /> INSULATION WINDOW FRAME _ TRIM PER ELEVATION HITHLICENSE FEE TO T OF <br /> -e L-L E'ER TYP. (WHERE OCCURS) BLDG.PAPER SEALANT BLDG.PAPER SEE ELEV.FOR (WHERE APPLICABLE) RIDGE HOMES. <br /> 10'-6'T_0 HOSE BIB IDI R PLAN SIDING PER PLAN WINDOW HT) <br /> -. 7/16'PLYWD.SHEATHING TRIM PER ELEVATION SEALANT <br /> B'-0 TO C.L. I D TRIM FORTIFLASH ON ALL PLAN SUMMARY <br /> OF PRONTO BEND (WHERE APPLICABLE) SIDES OF WINDOW SEALANT WINDOW FRAME a-. <br /> GE 3'-°' SIDING / INSIDE RNER T WINDOW SILL @ WOOD FRAME WALL WINDOW JAMB DETAIL rt WINDOW HEAD DETAIL N/A <br /> EWE TO EWE TO (/ -IQ -F 1.1/ nn iva n.ru <br /> EWE EWE _ELECTRICAL. \`W� SCALE:N.1".5..__...- -- VVU SCALE;N.T.S. W/ SCALE:N.T.S. VNb SCALE:N.T.S. <br /> METER MAIN um u•aa Fri <br /> 075 <br /> ® PRONTO BEND <br /> FRONT--- 5TUCIS @ 16'.(NO POI <br /> •XT OF D USE <br /> POINT LOADS ABOVE VENTS) <br /> CORNER %^Ek'T. OF NCUSE LAP SIDING U NO (HOLD I-IM' 1881 <br /> OF HOU5E OFF ADJOINING ROOF) xx..a_.M. <br /> AT GARAGE ---j HOSE LAG SCREW SIDING PER PLAN <br /> l�' BIBB 791 ATTACHED METAL FLASHING E0. L EO, ✓ 424 <br /> -GAS (MAY BE STEPPED) BOTTOM SILL PLATE * <br /> METER 1N5TALL J STUDS.LAG ELECTRIC <br /> GROUNDING -.1: PENETRATE BUILDING PAPER ON <br /> 3/4,TtG SUBFLOOR <br /> �IUI' IN.,TYP.III SHEATHING SIDING CUT w ra <br /> __.. Rvv 12, FRO-i_ ( FLASHING Jane unArs oxao•r. <br /> 2�3 HT OF AWAY FOR CLARITY <br /> PRONTO BE.`v ) <br /> FORTIFLASH o/FLASHING CH w/I ' o-�'� -- 7-I/2'zl5-I/2'CEDAR RIM <br /> AND MOISTOP.TURN i^P"r;O:STOF STRAP MIN METAL RAIN DIVERTER(THE BTL ENGINEERING <br /> VENTS w/GALV SCREEN- <br /> FORTIFLASH I'ONTO PANEL, PURPOSE IS TO SHED THE PROVIDE C6,—T EEVATIO VENTS <br /> ALL SIDES t CORNERS. OF 14 HATER OFF THE ROOF AND ROOF SHINGLES <br /> - KEEP IT AWAY FROM THE j RIM PER PLAN SEE REVISION LOG <br /> LASHING PER SPEC <br /> ceau rue Rwo. <br /> -f / <br /> 2x2 TRIM N PERIMETER _ TYP, VERTICAL WALL BENEATH). / P.T.MUD SILL SCALE:Y'=1'-0' <br /> 60 MIN,F,-LG OF NWT FASCIA PER PLAN w/ %� 30a ROOF FELT CONCRETE FOUNDATION ear mnsnv <br /> OPENING FOR ELSE--- GUTTER J <br /> METER BOX,FIREPLACE _ PAPER BEHIND /j 7/16"OSB ROOF -,DO NOT INSTALL VENT(5)CLOSER THAN 3'TO GAS METER" WATER <br /> DIRECT VENT,RANGE VENT, METER MAIN SHEATHING +eBUILDING PAPER SHOULD BE INSTALLED OVER FLASHING» INTRUSION <br /> DRYER VENT, ETC. / NOTE:PER WSEC R4022.7:WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE TOP DETAILS <br /> +SEE DETAIL WIG FOR M015TOP INSTALL IN5TRUCTIOPiS °. OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY <br /> _ MOTE: SEAL ALL ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL;TO <br /> ELECTRIC It GAS METER, NC�JL USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. _- <br /> W5 BIB CLEARANCES # LOCATIONS HATER HEATER (HWT) STRAPS W2 DETAIL @ ROOF/WALL INTERSECTION _, FOUNDATION VENT <br /> SCALE:N.T.5. KALE:N.T.S. SCALE:N.T.S. SCALE;N.T.S. <br />