SLIDING GLASS DOOR
<br /> SELF ADHESIVE PER PLAN
<br /> MEMBRANE PAN SLIDING GLASS DOOR EXTEND MIN.6'UP JAMB -
<br /> FLASHING NAIL FLANGE
<br /> NAIL ON FLEXIBLE \ GALV'Z'FLASHING NERVASTRAL TO EXTEND
<br /> FLASHING 2"MIN FROM TOP OF - 2' THE DOOR \HEADER/ I, \ HEADER/ `
<br /> FLOOR JOIST \I / LEDGER TO LAG SCREW \ ( \\ \\ // -
<br /> 2'PAST THE INTERIOR �
<br /> PER PLAN _ 5/4a4 CEDAR DECKING - - /
<br /> i
<br /> STUD ---
<br /> / PER PLAN WATER RESISTIVE 1- ROUGH ROUGH
<br /> — BARRIER /` OPENING OPENING .
<br /> 2x PT JOIST PER PLAN Lli JAMB\ JAMB\ I =
<br /> JOINT FLA5HiNG _ 2NU PIECE
<br /> li / SILL \ / SILL \ c.
<br /> HANGER PER PLAN - i `'^-
<br /> INSTALL PLANKS - 'III LASHING
<br /> RIM JOIST _-_-_ PT LEDGER PER PLAN CONTACRATE PENETRATION F 6• _
<br /> BUILDING PAPER
<br /> SHEATHING PER PLAN SST PIECE IL
<br /> 12'
<br /> INSTALLED BEHIND SIDING PER
<br /> LEDGER AN D LAP
<br /> SIDING PER PLAN PLAN -. _ BUILDING PAPER TO EXTENDFLASHIN
<br /> LEDGER INSTALLED BEFORE SIDING MIN.12'BEYOND ALL EDGES STEP I STEP 2 (�
<br /> OVER HOUSE WRAP — BEYOND - l
<br /> w/BUILDING PAPER BEHIND'�T wJ 5° C-
<br /> EXTEND 12' OF THE PENETRATION •ATTACH SILL STRIP OF 9'WIDE MOISTOP(OR EQ.)FLASHING MATERIAL •ATTACH JAMB STRIPS OF 9'WIDE MOISTOP(OR EQ.).
<br /> L--- .............. OPENING WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH IN51DE EDGE EVEN WITH THE JAMB
<br /> � - EXPOSED ON ALL 4 SIDES 'I •EXTEND THIS STRIP AT LEAST 12'BEYOND THE EDGE OF THE ROUGH OF THE ROUGH OPENING,
<br /> DECK LEDGER DETAIL SIDING BUTT UIN FLASHING OPENING. START JAMB STRIPS 2'BELOW SILL STRIP AND EXTEND 6"
<br /> EXTERIOR DOOR FLASHING PENETRATION PROTECTION •ATTACH FLASHING MATERIAL WITH CORROSION-RESISTANT STAPLES. ABOVE LOWER EDGE OF HEADER.
<br /> HILL -- WI6 SCALE:N.TS VVIS SCALE;N.T.S. WI4 SCALE:N.T.S.
<br /> N.T.S.
<br /> aWrrn m++v+mlca 1, CONT.BEAD OF
<br /> woxeLE HEAD --SEALANT
<br /> EQ. EQ. FLASHING UNDER NAIL FIN V
<br /> 5GD PER PLAN 2" ■ 2'
<br /> OPFRABLE PANEL
<br /> Q
<br /> '-- � PANEL �� CUT AWAY
<br /> ... WINDOW --EXCESS WINDOW /l/
<br /> LINE OF L-�—
<br /> FRAME OR BL P ER FRAME OR ' ' 1
<br /> NERVESTRAL ------T-- ---- "--I EQ_26 AEAmDES, CEDAR TRm, SIMILAR 1 @OPENING SIMILAR .Q W
<br /> V-6'TO HOSE BIB eorran OF EQ kl EQ Fr+r1Ll SIDES,uuLrJSFAL
<br /> YYI I� OPENING OPENING
<br /> 3'-6'TO SIDING i 3ouRL�ITTYP. NOTE: SEAL ALL
<br /> L.L.OF 1 F I NERYASTRAL EXPOSED FASTENERS BUILDING
<br /> PRONTO FRONT PORCH PATIO PAPERI PAPER
<br /> BEND ELECTRICAL 3'-6"LANDING TYP. SHEATHING PER PLAN PTYP
<br /> A
<br /> METER MAIN p BACK PATIO'S six Pare.swaao BLDG PAPS LINE Of BUILDING PAPER
<br /> s'""RED"'"E nPm.w' INSULATION
<br /> I-rxF rum slsE c+n�E NAIL FLANGE UNDER SILL STRIP
<br /> ss.D.W"wevmluE® PER PLAN PRONTO BEND APPROVED FLASHING
<br /> FROM INSTALLED ON DOOR N6 HEARTWOOD CEDAR TRIM (0.19 x 10'ROLL) STEP 3 STEP 4 z
<br /> CORNER M.OF HOUSE rHREs<vxD LANDING PER PUN.POUR •APPLY A 3/W CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME •APPLY THENEXT COURSE OF BUILDING PAPER(BUTTING TO THE O
<br /> OF HOU5E AGAINST NERVESTRAL 2x1 HEARTwEDD CEDAR SIDING PER PLAN 1-1/2'GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING)OVER THE JAMB FLASHING MATERIAL.
<br /> AT GARAGE _.i.— HOSE ______------ BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE ..!'\
<br /> ..I 30u FELT PAPER__ __ _ ram FLASHING a V�..J
<br /> NERVESTRAL HOUSE INTERSECTION, --
<br /> -LANDING PERPIAN _ _ INSTALLED JAMB AND SILL 1 JAMB MOISTOP OR E0. FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF
<br /> 1 ,�'- BBB WHERE OCCURS ( J l�
<br /> STARTER STRIP �''� (nIN.3,xe:,TYP.) i ROOF SHINGLES •NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS I/2 PAPER WIDTH.
<br /> INSTALL rv
<br /> _ ofsrEPST80 BY LINE OF NERVE5TRAI STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER
<br /> GROUNDING .__. sLA�ON GRACE ' 30#FELT TO EXTEND UP ABOVE THE AND BE
<br /> 12'FROM. _-- FLASHING— MUD slu 5RE CSTEPSRS - _ \ WALL 12'MIN. •THE UT <
<br /> ` ANY EXCESS BUILDING PAPER THAT MAY EXTEND
<br /> ROOF SHEATHING PER PLAN AAPPLY PPLY 6"�OROT FLASH OVER WEEN THE JAMBS OF THE OPENING. 1
<br /> PRONTO BEND wx.WALi _t
<br /> FORTIFLASH o/FLASHING \ LASHING @BOTH SIDES Of WINDOW
<br /> AIJD MOISTOP TURN-� 9"M015TOP GUTTER PER 1 / •ADD FORTIFLASH STICK f BACK,PREFINISHED METAL FLASHING TO OPENING.PLAN--- _ ROOF TRUSS III,I,L,,,,
<br /> A14D Mot
<br /> SH I"ONTO PANELS /T ER TOP HEAD FLANGE OF WINDOW.EXTEND PAST
<br /> ALL SIDES d CORNERS. FASCIA PER PLAN- EXT. LANDING DETAIL l ROOF TRUSS JAMB FLASHING 2".
<br /> `FLASHING FLASHING DE-I'AiL 4 EAVE SLIDING GLASS DOOR, TYP ROOF TO WALL FLASHING STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS _ z
<br /> LLA
<br /> &2 TRIM @ PERIMETERu
<br /> TYP C
<br /> - OPENING FOR ELEC. --60 MIN.BLDG WI3 SCALE:N.T S.---------- WIZ SCALE:N.T.S. WII SCALE:N.T.S. WIO SCALE:N.T.S. O
<br /> METER BOX,FIREPLACEPAPER BEHIND
<br /> DIRECT VENT,RANGE VENT, METER MAIN —
<br /> DRYER VENT, ETC. SEALANT WINDOW FRAME !`(1
<br /> 3/8'BEAD CAULK INSULATION 7/Ib"PLYWD.SHEATHING 1 , 1
<br /> +SEE DETAIL WIO FOR MOISTOP INSTALL INSTRUCTIONS SILL ASSEMBLY (WHERE OCCURS) 6"FORTIFLASH 0/FLASHING 1--1�--1
<br /> PER SPEC SEALANT �—
<br /> ELECTRIC METER NOSE BIB TRIM PER ELEVATION Gyp BD• WD FRAME WALL SIDING PER PLAN Q
<br /> NO GAS METER (WHERE APPLICABLE) INSULATION PER PLAN— BUILDING PAPER
<br /> LOCATIONL —
<br /> ( ) TRIMMER (WHERE OCCURS) R-10 INSULATION MOISTOP(SEE DETAIL WHO
<br /> SCALE:N.T.S. M015TOP(SEE DETAIL BEHIND 14DR,TYP @ FOR INSTALL)
<br /> GYP.BD. KING STUD MIN.1/4"GAP BTWN SIDING
<br /> WIO FOR INSTALL) ND,FRAME WALL ALL HOW'S7— - SEALANT PER PLAN GYP.BD. ��AND FLASHING
<br /> AIN.IB" EXT WALL PER FORTIFLASH ON ALL MOISTOP(SEE \.,y COPYRIGHT NOrICE:THIS
<br /> - PLAN SIDES OF WINDOW DETAIL WIO - --- HEADER PER PLAN FLA5HING TURN DOWN PLAN IS OPINED BY PACIFIC
<br /> 7/16'PLYWD.5WEA.T14ING 1/4'AT EACH END
<br /> FOR INSTALL -- RIDGE HOMES.u5E OF THIS
<br /> 11 SIDING PER PLAN ) PLAN Is PROHIBITED BY Law
<br /> INSULATION ' WINDOW FRAME / TRIM PER ELEVATION WITHOUTLIC PAYME
<br /> NT of
<br /> -JLLn. .'ER TYP, (WHERE OCCURS) BLDG.PAPER, BLDG.PAPER - SEE ELEV.FOR (WHERE APPLICABLE) RIM FEE TO PACIFIC
<br /> SEALANT WINDOW HT
<br /> l0 6"TO HOSE BIB -;iG M. 2 PLAN SIDING PER PLAN
<br /> 1 —7/16"PLYWD.SHEATHING TRIM PER ELEVATION \_ SEALANT PLAN SUMMARY
<br /> W-0 TO C.L. I x2 INN:D TRIM (WHERE APPLICABLE) FORTIFLASH ON ALL SEALANT —�
<br /> OF PRONTO BEND SIDES OF WINDOW WINDOW FRAME
<br /> ° 3'-0' SIDING / INSIDE C:-IRNER WINDOW SILL @WOOD FRAME WALL WINDOW JAMB DETAIL �1 WINDOW HEAD DETAIL N/A
<br /> EDGE TO EDGE TO __. Q I I.1'1 1.1/
<br /> EDGE EDGE _ELECTRICAL W� SCALE N.T.S. Wv SCALE:N.T.S. X�SLALE:N.T.S. PN� SCALE:N.T.S. 80j6
<br /> / METER MAIN w Pre,Ie�s
<br /> FP.Cw.--_ ® PRONTO BEND T1075 IT
<br /> INSALLED ON
<br /> CORNER EXT OF HOUSE LAP SIDING,U.NO.(HOLD I-I/2' STUDS @ 16'ac(NO POSTS/ IBBI
<br /> AT F USEGARAGE =1 / _HOSE OFF ADJOINING ROOF) POINT LOADS ABOVE VENTS)- �
<br /> LAG SCREW SIDING PER PLAN -
<br /> �" BIB6 �OSI I ATTACHED METAL FLASHING EQ. EQ. 424
<br /> GAS TO W;;I: iTUDS.LAG (MAY BE STEPPED) + —�
<br /> METER INSTALL BOTTOM SILL PLATE RET ELECTRIC
<br /> GROUNDING i RLN"1, PENETRATE +
<br /> ELECTRIC
<br /> BUILDING PAPER ON � 3/4'TtG SUBFLOOR ---
<br /> r— ROD 4"FROM JTUf. IN,,TYP.4 c3 �i'�i i i FLASHING
<br /> PRONTO BEND SHEATHING(SIDING CUT
<br /> 1/' .I 2/3 HT OF AWAY FOR CLARITY) w _
<br /> FORTIFLASH o/FLASHING FI':dl • .CH w/I ' , 7-I/2'xl5-I/2'CJVENTS
<br /> WA
<br /> AND MOISTOP.TURN —9"I':OISTOP .: STRAP MIN METAL RAIN DIVERTER(THE BTL ENGINEERING
<br /> FORTIFLASH I"ONTO PANEL, PURPOSE 15 TO SHED THE VENTS w/GALVALL SIDES 6 CORNERS. OF HWT WATER OFF THE ROOF AND ROOF 5HINGLES PROVIDE LOUVEKEEP IT AWAY FROM THE j @FRONT ELEVA
<br /> 2x2 TRIM @ PERIMETER `FLASHING / PER SPEC S�Eµu.o510N LOG
<br /> RIM PER PLAN
<br /> VERTICAL WALL BENEATH).
<br /> TYP. r%' P.T.MUD SILL / 5CALE:Y" V-O"
<br /> OPENING FOR ELEC. _ 60 MIN.BLDG OF HWT FASCIA PER PLAN w/ 301E ROOF FELT CONCRETE FOUNDATION affr anans
<br /> METER BOX,FIREPLACE PAPER BEHIND GUTTER rxpp NOT INSTALL VENT(S)CL05ER THAN 3'TO GAS METER,-
<br /> DIRECT VENT,RANGE VENT, METER MAIN 7/I6"O58 ROOF WATER
<br /> DRYER VENT, ETC. SHEATHING "BUILDING PAPER SHOULD BE INSTALLED OVER FLASHING++ INTRUSION
<br /> NOTE:PER WSEC R402.2.7+WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE TOP DETAILS
<br /> +SEE DETAIL WIO FOR M015TOP INSTALL INSTRUCTIONS - \` OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY wm_ - - -' #NOTE: SEAL ALL \, ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO
<br /> ELECTRIC t GAS METER, HOSE NOI! USE 3 STRAPS ON 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,
<br /> BIB CLEARANCES $ LOCATIONS ~. DATER HEATER (HINT) STRAPS DETAIL @ROOF/WALL INTERSECTION FOUNDATION VENT /� 1
<br /> W5 SCALE:N.T.S. W-I' KALE:N.T.S. W2 5CALE:N.T.S. YVI 5CALE:N.T.S. f�
<br />
|