FLOOR PLAN NOTES <br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,MATERIALS t CONDITIONS PRIOR TO <br /> CONSTRUCTION. <br /> WINDOWS 4 DOORS: <br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/R-10 INSULATION, <br /> 3. WINDOWS t DOORS ARE SHOWN t NOTED AS NOMINAL SIZES. <br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R.O.G <br /> MAX.42'A.F.F. <br /> 5. ALL WOOD IN CONTACT WITH CONIC.TO BE PRESSURE TREATED. <br /> 6. EXTERIOR WALLS TO BE 26 STUDS 0 16"O.C.,U.NO. <br /> 7, GARAGE DOOR HEADERS P 84'A.F.F. � 0' <br /> B. EXTERIOR SWING DOOR HEADERS @ 83 1/2"A.F.F. <br /> 9. INTERIOR SWING DOOR HEADERS P 83'A.F.F. <br /> 10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS QR BE 3'MIN.ON HINGE SIDE, <br /> 11. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD 136'THICK 20-MINUTE FIRE-RATED DOOR Sz -{ - <br /> w/A SELF CLOSING HARDWARE DEVICE. 4'-0y° 0-W 4'-ri' <br /> 12. PER R311.3.1:THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOORS <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4'BELOW THE TOP OF THE <br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR <br /> 13. ALL BI-FOLD t BI-PASS DOORS TO BE CENTERED,U.N.O. <br /> FRAMING: <br /> co <br /> 14, VERIFY FIREPLACE STYLE t LOCATION w/SUPERVISOR PRIOR TO CONST. 6046 XO 2030 XO <br /> 15. FRAMERS TO INSTALL ALL WINDOWS t INTERIOR COLUMNS (EGRESS) (085) <br /> Ib. TOWEL RING BLK'G 0 57'A.F.F. --- ----- - --'f O <br /> 17. TOWEL BAR BLK'G A 48'A.F.F.t BLOCK BOTH BAYS. <br /> 18. TOIIET PAPER HOLDER BLK'G P 22°A.F.F.AND 42"FR <br /> OM BACK WALL WHERE POSSIBLE <br /> 19. THERMOSTAT BLK'G?60'A.F.F - - <br /> 20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE INSTALLED AT T-6'A.F.F. T 60'VANITY ro <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE <br /> GARAGE DOOR TRIM 2668 CPT BATH I Hs car_ 6q I SF i-- �-/22. ADD CONT.BLOCKING FOR STAIR HANDRAIL BRACKETS BEDROOM I - us TT SF - 1 ,�' <br /> 23. STAIRS w/WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL INSTALLED ON I '_I i'-7" `^ 36'x80'GWB _ <br /> THE INSIDE OF THE STAIR'S RUN 13 XIQ 4 - FINISHED <br /> 24. LADDER-BLOCK AT EXTERIOR WALLS AS NECE55ARY FOR INSULATION INSTALL y y�- OPENING v <br /> ci TB T2 <br /> VENTILATION: m 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED ---___BY A CENTRAL EXHAUST FAN IN _ <br /> ACCORDANCE WITH M1505.4.1.1. 4''Skt' EDD <br /> 26. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY. (TO FACE OF RISER) so <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(I).EXAMPLE!70 CFM FOR%61A <br /> SF HOME w/4 BEDROOMS,AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE WHOLE W Z <br /> MI505.4.3(2)TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED VENTILATION SYSTEM. MINI-SPLIT 3,_1 q, " HOUSE <br /> 0N <br /> 28. WHOLE HOUSE FAN SHALL BE 1.0 5E5 OR LESS, AND SHALL.HAVE AN EFFICACY OF 2.8 /�� <br /> CFM/WATT PER WSEC R403.6.1. 2x6 W LL U ' D - 'co - <br /> A I� 22'x30x CPT <br /> 29. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOWS PER STATE -10° Y ED/0 ATTIC Hs 2868 - 5'3x9'7 �0p �- <br /> CODE INTERPRETATION 17-15. YYY ACCESS P xb WALL <br /> 30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE 3,_6 DN - 5'-9' 3'-6' <br /> WHOLE HOUSE FAN. _ 15R,14T m q_p INI-SPLIT <br /> 51, PER IRC M1502.4.5.-WHERE THE DRYER VENT EXHAUST DUCT 15 CONCEALED WITHIN THE ° BF <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE % 50°H I/2 WALL 9'-4° _ �� Y °o , <br /> IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED ° _q 5'-V' W/S(3) - 1--1--t <br /> WITHIN 6FT OF THE EXHAUST DUCT CONNECTION, 3'-I 42'H HALF 10' <br /> WALL <br /> LIFE SAFETY: b 3 OPEN TO a 2665 us o^ OLu <br /> 26. A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPERATURES AND 4 BELOW ' _PT >< <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. - e BEDROOM 2 <br /> 27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE - x STAIRS w/ BA Z <br /> ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROOM OR WINDER STEPS T � q'7x13'2 <br /> 3'-b WILL ALWAYS 5 OX9 l _ <br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION DOUBLE RIM OR 38°H NAVE A <br /> 10. SMOKE DETECTORS TO BE 110V, INTERCONNECTED; w/BATTERY BACKUP t CENTRALLY PROVIDE SPLICE ° 38 1/2 WALL CONTINUOUS <br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE u <br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 HANDRAIL TB - <br /> _ m <br /> II. SMOKE DETECTORS SHALL BE INSTALLED 0 , a 14T INSTALLED ON 4-0 <br /> NET LESS THAN 3 FT HORIZONTALLY FROM THE THE INSIDE OF ®OO O5D <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER.CR31q] THE STAIR RUN 60'x32" <br /> 12. IONIZATION SMOKE ALARMS: <br /> x SHALL NOT BE INSTALLED LESS THAN 20 FT HORIZONTALLY FROM A PERMANENTLY °TUB/SNWR 2668 21 ALL W/5(I) - <br /> INSTALLED COOKING APPLIANCE. ADD FLAT <br /> x IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH SHALL NOT BE INSTALLED 2X4 THROUGH T_02� 5' 3'6- 266E q,_� MI I-SPLIT I ° <br /> LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. JOIST P 5'O.C. V"X6" --- - - ° � <br /> 24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FT _ COPYRwuT N II nos <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE M141 r D PUN 15 ONNED BY PACIRC <br /> 26,GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2'G.W.B.15/8" 11,� 'VVx r z RIDGE 1 L 5.USE OF THIS <br /> �3"XBy �'SD PUN 15 PROHIBITED BY UW <br /> TYPE'X'ON THE CEILING.POLY SEAL RIM, ENTIRE GARAGE TO MEET JURISDICTION rm„m I WITNOJT PAYMENT OF <br /> DRAFT STOP REQUIREMENTS LCENSE FEE TO PAGFK <br /> 26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH Y2'GWB AT THE i F BEDROOM 4 1 BEDROOM 3 RIDGE HO'a <br /> WALLS,UNDER-STAIR SURFACES AND SOFFITS. STT HRS416Z. § 10'Q%II'Q 1 9'7%II'10' <br /> 27. PROVIDE FIREBLOCKING PER PLAN AND P ALL PLUMBING PENETRATIONS. ATTACH TO SECTION TNRU iN a i m = PLAN SUMMARY <br /> 2x AND TO WALL CAP 3 3 i _ Iwo ova u e,eaen m n.. <br /> STAIR RIM i i N/A <br /> I 1 _ <br /> I I m.fr• <br /> � 806 <br /> 7046 XOX(EGRESS) 1075 mn <br /> w/GRID PER ELEV. <br /> �1 HALF WALL FRAMING t CAP DETAIL 4040 XQ <br /> VIJ SCALE 1/2'•I-V' LINE OF (EGRESS) cuucE au m.n• <br /> WALL BELOW w/GRID 424 <br /> PER ELEV. <br /> ELECTRIC <br /> Nanarwu.nm aaaw*au <br /> JWA <br /> -PROVIDE MIN.30' ATTIC ACCESS ucwxe, <br /> HEADROOM CLEARANCE. SHEATHING ON <br /> -TRU55E5 MUST BE OUTSIDE OF T 0° 2'7° B7L ENGINEERING <br /> INSTALLED 0 24'O.C. TRUSS MEMBERS -SEE REVISION LOG <br /> O O 12'-2Y2° 2'-7° I'-10' 3'-3'11 4'-0' _ 3'-3' ceew ruE urn. <br /> 1 A' SCALE:Y"= I'-0" <br /> 2-1 1V-7)¢" 10'-6' soar rxxrerts <br /> 30'-0° <br /> 5/4 TRIM GWB ATTIC UPPER FLOOR PLAN <br /> OR 51M. ACCESS LID <br /> ATTIC ACCESS DETAIL UPPER FLOOR PLAN - 'AI t IB' ELEV'S <br /> VJ1 SCALE-1/2'•1'-0' SCALE: 1/4'-1'-0' <br /> (1A' 4 'B' ELEV'S) <br />