SLIDING GLASS DOOR
<br /> SELF ADHESIVE PER PLAN
<br /> MEMBRANE PAN SLIDING GLASS DOOR EXTEND MIN.6'UP JAMB
<br /> FLASHING NAIL FLANGE
<br /> NAIL ON FLEXIBLE GAL'✓T FLASHING NERVASTRAL TO EXTEND
<br /> FLASHING 2"MIN FROM TOP OF 2"PAST THE INTERIOR OF THE DOOR \ HEADER/ \ HEADER/ _
<br /> �\
<br /> FLOOR JOIST �\ ' LEDGER TO LAG SCREW STUD
<br /> PER,PLAN 5/44 CEDAR DECKING '
<br /> PER PLAN WATER-RESISTIVE / I. ROUGH ROUGH
<br /> w BARRIER OPENING OPENING
<br /> -- I _
<br /> -2x PT JOIST PER PLAN
<br /> JAMB\ JAMS\
<br /> RIM JOINT FLASHING 2ND
<br /> ' HANGER PER FLAN �-'- Pltc / SILL
<br /> INSTALL PLANKS
<br /> JOIST IN MODERATE _ --�I IfC E PENETRATION 6• III,! I"""""
<br /> - -PT LEDGER PER PLAN CONTACT-- -- ---" lsT p '5
<br /> BUILDING PAPER - I
<br /> INSTALLED BEHIND y SHEATHING PER PLAN - I2•
<br /> SILL
<br /> c.
<br /> SIDING PER FLASHING I
<br /> LEDGER AND PAN /-SIDING PER PLAN PLAY------ - BUILDING PAPER TO EXTEND (''�
<br /> FLASH NG.LAP -I LEDGER INSTALLED BEFORE SIDING MIN.12'BEYOND ALL EWES
<br /> Q
<br /> OVER HOUSE WRAP EXTEND 12"BEYOND = OF THE PENETRATION STEP I
<br /> w/BUILDING PAPER BEHIND IT w/b' •ATTACH SILL STRIP OF 9"WIDE M015TOP(OR EQ.)FLASHING MATERIAL ••ASTTTACN JAMB STRIPS OF q'WIDE MOI5TOP(OR EQ.). w
<br /> EXPOSED ON ALL 4 SIDES i'1 I OPENING
<br /> WITH THE TOP EWE EVEN WITH THE TOP OF THE ROUGH SILL. FLASHING MATERIAL WITH INSIDE EWE EVEN WITH THE JAMB
<br /> DECK LEDGER DETAIL SIDING BUTT J JI FLASHING EXTEND THIS STRIP AT LEAST 12"BEYOND THE EWE OF THE ROUGH OF THE ROUGH OPENING. z
<br /> �\ ^ II •START JAMB STRIPS 2"BELOW SILL STRIP AND EXTEND 6"
<br /> 1 046
<br /> r / \ EXTERIOR DOOR FLASHING � PENETRATION PROTECTION •ATTACH OPENING.
<br /> MATERIAL WITH CORROSION-RE515TANT STAPLES. ABOVE LOWER EWE OF HEADER. m
<br /> YVLL I.I1 LII A CID
<br /> N.T.S. VV I SCALE:N.T,S VV I V SCALE:N.T.S. VV 19 SCALE:N.T.S. nn/
<br /> CBITER TRN/LANx16 W O
<br /> rwart Lbx x wDusle CANT.BEAD OF W U
<br /> six a slwae -HEAD SEA
<br /> LANTUNDER NAIL FIN
<br /> EQ. EQ. FLASHING 2' 2'
<br /> 54D PER PLAN
<br /> OPERABLE PAL CUT AWAY ,, 11
<br /> J WINDOW EXCESS WINDOW l--L-
<br /> WNE OF .-.__-- -. —___._—_-
<br /> NERVESTRAL --- ---- ------ -- a.A HEARTH:VD wDAR rRln, FRAME OR BLDG.PAPER FRAME OR
<br /> BEHIND I i--EQ.ALL SIDES,CAULr✓SFAL SIMILAR
<br /> eH.O5E SIMILAR @OPENING Q
<br /> B07170MOFEQ. OPENING SIDING j I -POU LANDING M. NOTE: SEAL ALL AGAINST EXPOSED FASTENERS BUILDING
<br /> PRONTO FRONT FCRCA PATIO BUILDING PAPER
<br /> BEND ELECTRICAL 3'-bI LANDING TAP. SHEATHING PER PLAN PAPTAPER TIP.
<br /> METER MAIN P BALK PAT Paam MR%IW LINE OF BUILDING PAPER
<br /> Nxm yx a INSULATION BLW PAPER NAIL FLANGE UNDER SILL STRIP
<br /> ® s.e.o.HauvER rowlne -
<br /> PRONTO BEND PER PLAN APPROVED FLASHING
<br /> FRONT OK HEARTWOOD CEDAR TRIM STEP 3 STEP 4
<br /> INSTALLED ON TOOK (0.19 x 10'ROLL)
<br /> CORNER �C[.OF HOUSE rHRrvaLD LNlDIlY.PER PUN.Pg1R •APPLY A 3/8°CONTINUOUS BEAD OF CAULK TO THE BACK Of THE FRAME •APPLY THE NEXT COURSE OF BUILDING PAPER(BUTTING TO THE -�
<br /> AGAINST NERVESTRAL
<br /> 36 NEARTWND CEDAR
<br /> OF HOUSE SIDING PER PLAN I-I/2'GAP NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING)OVER THE JAMB FLASHING MATERIAL.
<br /> AT GARAGE - HOSE 30tt FELT PAPER- BTWN ROOF AND SIDING •PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE —
<br /> NERVESTRAL __ �{/I HOUSE INTERSECTION, ., y J
<br /> ®�BIBB STARTER STRIP-- LARDING PEP oL u I- - xAIERE acuRs INSTALLED JAMB AND SILL{JAMB MOISTOP(OR FA.)FLASHING MATERIAL. BOARD FASHION UP THE WALL,LAPPING COURSES A MINIMUM OF
<br /> INSTALL rt': tM s,TrP/ i ROOF SHINGLES .NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH.
<br /> -a DF STEPS.TED BY LINE OF NERVESTRAL � •STARTING FROM THE BASE OF THE WALL,APPLY BUILDING PAPER UNDER
<br /> GROUNDING FLASHING _ MUD SILL •rE nnor!oNs 30#FELT TO EXTEND UP
<br /> -�--ROD 12'FROM __ - - I WALL 12'MIN. THE SILL ABWE THE SILL AND BETWEENHEIP AND CUT ANY SJAM0510FNG PAPER THE OPENING.AT MAY EXTEND
<br /> --'- SLAB ON GRADE
<br /> AND MOISTOP FLASHING PRONTO BEND GUTTER PER ,\ �I [oNc wAtL •ADD FORTIFLASH STICK FLASHING @ BOTH SIDES OF WINDOW
<br /> PLAN----� "- ROOF TRU55 W°FOR fPDXt°IX* •APPLY SLOPED 28 GA..2'BACK,PREFINISHED METAL FLASHING TO OPENING. �-� '�
<br /> ALL SIDES t TURN - 9°MOISTOP / '` ,` 'ND FKM wRa1 SAE •APPLY 6'FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW.EXTEND PAST
<br /> ROOF SHEATHING PER PLAN
<br /> ALL 51DESH I"ONTO PANEL FASCIA PER PLAN EXT. LANDING DETAIL @ ROOF TRUSS JAMB FLASHING 2",
<br /> 0
<br /> CORNERS
<br /> FLASHING FL_A5N1_NG DET- I:. @ EAVE SLIDING GLASS DOOR TYP ROOF TO WALL FLASHING Lu
<br /> STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS O
<br /> 2x2 TRIM P PERIMETERS-- TYp,
<br /> I•I _ LI�T I LIII 1.11/1
<br /> OPENING FOR ELEC.-.. 60 MIN.6LDG VV13 SCALE:N.1.5 VVIL SCALE:N.T.S. ry11 SCALE:N.T.S. VVIV SCALE:N.T.S.
<br /> METER BOX,FIREPLACE PAPER BEHIND
<br /> DIRECT VENT,RANGE VENT, METER PW!N SEALANT 7/Ib"PLYWD.SHEATHING
<br /> DRYER VENT,ETC. —\ WINDOW FRAME INSULATION
<br /> +SEE DETAIL WIO FOR MOISTOP INSTALL INSTRUCTIONS SILL SPEC ASSEMBLY \\ 3/8"BEAD CAULK (WHERE OCCURS) b'FORTIFL4-%0/FLASHING �---
<br /> ELECTRIC METER HOSE BIB PER SPEC SEALANT GYP.BD. ND.FRAME WALL SIDING PER PLAN
<br /> TRIM PER ELEVATION ��'-
<br /> LOCATION (NO GAS METER) PER PLAN
<br /> (WHERE APPLICABLE) INSULATION BUILDING PAPER
<br /> (WHERE OCCURS)
<br /> SCALE:N.T.S. TRIMMER R-10 INSULATION MOISTOP(SEE DETAIL WHO
<br /> GYP.BD. MOISTOP(SEE DETAIL KING STUD BEHIND NDR,TYP @ FOR INSTALL)
<br /> WIO FOR INSTALL) WD.FRAME WALL ALL HDR's MIN. /4"GAP BTWN SIDING
<br /> -`yII SEALANT PER PLAN �^AND FLASHING cwlwraIT Nnlce.rHs
<br /> MIN.IB" EXT WALL PER FORTIFLASH ON ALL GYP.BD.
<br /> I PLAN MOISTOP(SEE PLAN Is auIED BY PACIFIC
<br /> - - SIDES OF WINDOW DETAIL WIO HEADER PER PLAN ~FLASHING TURN DOWN RIDGE HOMES.USE of TUIs
<br /> FOR INSTALL 7/Ib'PLYWD.SHEATHING /4'AT EACH END PLAN Is PRwlalrm BY LAW
<br /> -.-_� SIDING PER PLAN ) wmarr ParnENr of
<br /> LICENSE FEE TO PACIFIC
<br /> ��- INSULATION WINDOW FRAME --TRIM PER ELEVATION WDrk Hq.�
<br /> F L,; .Apt TrP. (WHERE OCCURS) BLDG.PAPER BLW,PAPER SEE ELEV.FOR (WHERE APPLICABLE)
<br /> eOIT�T'O'H.EBIB II, ?ER PLAN SEALANT SIDING PER PLAN WINDOW HT)7/16'PLYWD.SHEATHING TRIM PER ELEVATION SEALANT PLAN 5UMMARY
<br /> VIED TRIM (WHERE APPLICABLE) FORTIFLASH ON ALL SEALANT ua Ls9.uaeeoRn rt•
<br /> OF PRONTO BEND —J� SIDES OF WINDOW `-WINDOW FRAME
<br /> EDGE TOEDGE
<br /> O`O SIDING i N51Di_= _)RNER ,,,Q WINDOWSILL @ WOOD FRAME WALL WINDOW JAMB DETAIL /,� WINDON HEAD DETAIL
<br /> EWE EWE _ELECTRICAL N_I SCALE:N.T.S. VVV ALE,N.T.5. VV/ SCALE:N.T.S. VVb SCALE:N.T.S. 814
<br /> METER MAIN 119
<br /> 5 m.n,
<br /> T ® PRCTNTO BEND
<br /> FRONT- INSTALLED ON T0f MPA �'
<br /> CORNER STUDS C,I6'o< NO POSTS/
<br /> OF HOUSE EXT.OF HOUSE / POINT LOADS ABOVE VENTS)--� 2009
<br /> LAP SIDING,U.NO.(HOLE)I-I/2' �./,%'
<br /> AT GARAGE - - - � HOSE OFF ADJOINING ROOF)
<br /> 01-BIBB / 'SCREW METAL FLASHING �" x L EQ L SIDING PER PLAN—�� 405
<br /> GAS --Y ATTACHED x
<br /> METER INSTALL .STUDS.LAG (MAY BE STEPPED) /� - • �� BOTTOM SILL PLATE
<br /> GPOUND114G D PENETRATE BUILDING PAPER ON /� --3/4'T.SUBFLOOR GAS
<br /> --- --- ROD 12"FROM - MIN.,TYP.@ SHEATHING SIDING CUT
<br /> ( FLASHING JWA
<br /> PRONTO BEND dD 2/3 HT OF AWAY FOR CLARITY) I I I 7-/2'xl5-I/2'CEDAR RIM
<br /> FORTIFLASH o/FLASHING TACK w/I'i6° I I I I au•ssx,
<br /> AND MOISTOP.TURN �-9°MOISTOP V STRAP MIN METAL RAIN DIVERTER(THE „g I VENTS w/GALV SCREEN-
<br /> i 1 1 BTL ENGINEERING
<br /> FORTIFLASH I"ONTO PANEL, PURPOSE 15 TO SHED THE PROVIDE LOUVERED VENTS _
<br /> ALL SIDES<CORNERS. HT OF HWT SEE REVISION LW
<br /> WATER OFF THE ROOF AND @FRONT ELEVATIONS
<br /> --FLA5W NG KEEP IT AWAY FROM THE i ROOF SHINGLES
<br /> 2x2 TRIM @ PERIMETER-- TYP, VERTICAL WALL BENEATH). PER SPEC. —RIM PER PLANy"•s o
<br /> l/ P.T.MUD SILL
<br /> SCALE: Y°,I'-0"
<br /> OPENING FOR ELEC. ti - 60 MIN BLDG - IT OF HWT FASCIA PER PLAN w/ 30U ROOF FELT CONCRETE FOUNDATION slsn rmms
<br /> METER BOX,FIREPLACE PAPER BEHIND GUTTER
<br /> DIRECT VENT,RANGE VENT, METER MAIN 7/I6'055 ROOF $$DO NOT INSTALL VENT(S)CLOSER THAN 3'TO GAS METER„ WATER
<br /> DRYER VENT, ETC. \ 514EATWING „BUILDING PAPER SHOULD BE INSTALLED OVER FLASHING,- INTRUSION
<br /> NOTE:PER WSEC R402.2.7:WHEN FOUNDATION VENTS ARE NOT PLACED SO THAT THE TOP DETAILS
<br /> +SEE DETAIL WIO FOR MOISTOP INSTALL INSTRUCTIONS OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION,A PERMANENTLY
<br /> ELECTRIC GAS METER HOSE sNOTE: SEAL ALL ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30'FROM HORIZONTAL,TO
<br /> I USE 3 STRAPS O4 75 GALLON AND GREATER SIZES EXPOSED FASTENERS DIVERT AIR FLOW BELOW THE LONER SURFACE OF THE FLOOR INSULATION,
<br /> BIB CLEARANCES t LOCATIONS WATER HEATER (HAT) STRAPS DETAIL @ ROOF/WALL INTERSECTION FOUNDATION VENT 1 0
<br /> SCALE:N.T.S. '`I SCALE:N.T.5, YVG SCALE;N.T.S. VV SCALE:N.T.S. ---
<br />
|