Laserfiche WebLink
Ib' <br /> FLOOR PLAN NOTES A <br /> q OF SOAP NICHE,SHOWER PEPLAN <br /> CONTROL t SHOWER PAN <br /> PEX TUBING, lI <br /> 1. CONTRACTOR SHALL VERIFY ALL NOTES TYP., MATERIALS t CONDITIONS PRIOR TO SHOWER CONTROLS <br /> CONSTRUCTION. <br /> I6'x24'x6'DEEP <br /> WINDOWS 3 DOORS: SOAP NICHE <br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/R-10 INSULATION. BUTT NICHE TILE <br /> 3. WINDOWS t DOORS ARE SHOWN t NOTED AS NOMINAL SIZES, INTO FIELD TILE, <br /> 4. WINOCK HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R.Q @ TOP t 51 DES _ _ <br /> MAX.42'A.F.F. SE*�NA-ABUTT FIELD24'5. ALL WOOD IN CONTACT WITH CONC.TO BE PRESSURE TREATED. "- <br /> 6. EXTERIOR WALLS TO BE 2x6 STUDS P 16'O.C.,U.NO. (ZOOMED IN @ NICHE) TILE INTO <br /> 7. GARAGE DOOR HEADERS @ 84'A.F.F. BOTTOM OF B. EXTERIOR SWING DOOR HEADERS @ 53 1/2"A.F.F. NICHE TILE <br /> (3)LAYERS I" I, I4'-44' <br /> 9. INTERIOR SWING DOOR HEADERS @ 83"A.F.F. POLY-I50 RIGID APPROX.STUD <br /> - 10. SWING DOORS 70 FOLLOW CENTERLINE DIMENSION IN PLANS OR BE 3"MIN.ON HINGE SIDE, INSULATION, ID LAYOUT <br /> 5_fb1° b'_p, 4'-7' 8'_2" 2'-0' 4'-V22' <br /> 11. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD IV THICK 20-MINUTE FIRE-RATED DOOR WALLS ONLY <br /> w✓A SELF CLOSING HARDWARE DEVICE. SHOWER <br /> 12. PER R311.3.1:THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOORS M - <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4'BELOW THE TOP OF THE `i II ° - - <br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR FIELD TILE w <br /> 2030 <br /> 13. ALL EH-FOLD t BI-PASS DOORS TO BE CENTERED,U.N.O. `-° XO <br /> 4�° <br /> FRAMING: - SHOWER PAN I 6046 XO(EGRESS) �085� <br /> 14. VERIFY FIREPLACE STYLE t LOCATION w/SUPERVISOR PRIOR TO CONST. CPT T <br /> 15, FRAMERS TO INSTALL ALL WINDOWS t INTERIOR COLUMNS SECTION A-A 2x6 0,2x4 2x8 WALL, SECTION A-A <br /> 16, TOWEL RING SLK'G @ 57'A.F.F. (@ EXTERIOR WALL] WALL PER PLAN BALK WALL OF (@ INTERIOR WALL) �_ �, H5 O <br /> 17, TOWEL BAR BLK'G @ 48°A.F.F.t BLOCK BOTH BAYS. SHOWER,TYP. 2'-51" 2'-6° 1'-�" b'-6" <br /> 18. TOILET PAPER HOLDER BLK'G @ 22'A.F.F.AND 42"FROM BACK WALL WHERE POSSIBLE n[ SNOW ER SOAP NICHE <br /> 20 THERMOSTAT BLK' @ 60" B5 Q �� BATH I <br /> 20. EXTERIOR LIGHT BLOCKS ATT ALL FRONT ENTRY'S SHALL BE INSTALLED AT T-6"A.F.F. SCALE:NTS \J <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE <br /> GARAGE DOOR TRIM f T <br /> 22. ADD CONT.BLOCKING FOR STAIR HANDRAIL BRACKETS qlb" <br /> 23, STAIRS w/WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL INSTALLED ON BEDROOM I 30„xEp" 1 -2' .Q W <br /> THE INSI OF THE STAIR'S RUN - 12 3X5 2 GWB FINISHED - <br /> DOUBLE RIM IC _ <br /> 24. LADDER-BLOCK AT EXTERIOR WALLS AS NECESSARY FOR INSULATION INSTALL ^i OPENING I� SH" ER <br /> PROVIDE SPLICE i WIC I,7 TB _ <br /> VENTILATION: - 6'IOxg'10 ; 2° <br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL EXHAUST FAN IN 1 <br /> ACCORDANCE WITH M1505.4.1.1. ' *ATTIC I s x L 26, WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY. O5D <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M505.43(I).EXAMPLE:70 CFM FOR 2600 <br /> ADD FLAT <br /> ACCESS <br /> MINI-SPLIT W/5(I) <br /> 5F HOME w/4 BEDROOIMS,AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE L J TP <br /> M1505.4.3(2)TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED VENTILATION SYSTEM. 2X4 THROUGH <br /> 28. WHOLE HOUSE FAN SHALL BE 1.0 SONES OR LESS,AND SHALL HAVE AN EFFICACY OF 2.8 J0157 @ 5'O.C. S/Xb' MINI-SPLIT 2xb WALL <br /> CFM/WATT PER WSEC R403.6.1. W/5 3 UTILITY 11 cc) - <br /> 2q. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOWS PER STATE - U71LI Y �---� 1� �- <br /> CODE INTERPRETATION 17-15. 20 SF <br /> io- <br /> 30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE x32 H5 wu <br /> WHOLE HOUSE FAN. 12'-b}° 2'-10' 3'-8' GP 3'_q" T-2}° o I <br /> 31, PER IRO MI502.4.5.:WHERE THE DRYER VENT EXHAUST DUCT IS CONCEALED WITHIN THE _og60 1 <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE STT HR5416Z. _ <br /> _ IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED SECTION THRU <br /> WITHIN 6FT OF THE EXHAUST DUCT CONNECTION. ATTACH TO WALL CAP <br /> 2x AND TO _ LOFT o <br /> LIFE SAFETY: STAIR RIM o 3'gxl8'7 4s"VANITY rP' 32"xbo" a Z <br /> 26, A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPERATURES AND <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE, CPT HALL BATH HOWE - <br /> 27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE b 5'XIO'3 <br /> ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROOM OR TB <br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION kk - <br /> 10. SMOKE DETECTORS TO BE IIOV, INTERCONNECTED,w/BATTERY BACKUP t CENTRALLY HALF WALL FRAMING ¢ CAP DETAIL � ------xJ/S,1)____- <br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE DI5 SCALE:1/2'-1-0" SD/CO Vl- <br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 - - I'-2� <br /> II. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM THE 15R,14T EQ EQ <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER.LR3W] ON _ <br /> 12, IONIZATION SMOKE ALARMS ,T 42 H HALF WALL W/5(1) SD <br /> ° SHALL NOT BE INSTALLED LESS THAN 20 FT HORIZONTALLY FROM A PERMANENTLY SD <br /> INSTALLED COOKING APPLIANCE. -PROVIDE MIN.30' ATTIC ACCESS <br /> x _ ______________ <br /> IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH SHALL NOT BE INSTALLED sT <br /> LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE, HEADROOM CLEARANCE. SHEATHING ON <br /> 24. PHOTO ELECTRICE:THIS <br /> C SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6FT -TRUSSES MUST BE OUTSIDE OF rt EQ q0 BF EO 5D <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE[R314] INSTALLED @ 24'O.C. TRUSS MEMBERS sT O �15 LWNEDGWT I BY PACIFIC <br /> 26,GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH V2'G.W.B.a 5/�' - 6T z RIDGE HOMES.USE OF THE <br /> TYPE'X'ON THE CEILING.POLY SEAL RIM,EtJTiRE GARAGE TO MEET JURISDICTION q - .� z OPEN TO 6'-7° 3'-2" 3'-b' 6'-9' PLAN 1s PRaH1B1rEo BY w+ <br /> WITHOUT PAYMENT OF <br /> DRAFT STOP REQUIREMENTS nT S BELOW LKBSE FEE TO PAc1FIc <br /> 26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH Y1'GWB AT THE11 3' m b'-dy' a ~ DODGE HOMES. <br /> WALLS,UNDER-STAIR SURFACES AND SOFFITS. <br /> 27. PROVIDE FIREBLOCKING PER PLAN AND @ ALL PLUMBING PENETRATIONS. 3B'14 HALF m PLAN SUMMARY <br /> 6/4 TRIM GWB ATTIC rtr WALL 3 umaaseenn Fr. <br /> OR SIM. ACCESS LID '=T <br /> ATTIC ACCESS DETAIL BEDROOM 2 BEDROOM 3 "517.1' <br /> SCALE:1/2'-P-0' q'4x12'9' 9'416'10 one, xi R. <br /> I Iq5 <br /> GROUT t 4020 PIC 200q <br /> ATUB - <br /> P cuevc Ns. <br /> SHOWER GLASS t 5046 XO(EGRESS) 5046 XO(EGRESS) 405 <br /> FRAME w/GRID PER ELEV. w/GRID PER ELEV. -- <br /> CAP ILE °AP y LINE OF WALL BELOW GAS <br /> DRYWALLA-A m,LE 12%S.A.M,7 BITUT14ENE J BTL ENGINEERING <br /> OR EQUIV. a 2'-7 ' 5'-0' 2-t! 2'-7Y' 5'-0' 2'-7y4'2x4 STACKED SEE REVISION LOG <br /> BLOCKING AT 3'-2 " q'-p" 2'-�' UMDSHOWER CURB. �'AT HALFSCALE: Y,'=1'-0' <br /> WALL,FRAME 10'-0° 20'-0° runena <br /> LIKE HALF sxxr <br /> SUB FLOOR WALL. w 30'-0' UPPER FLOOR PLAN <br /> TILED SHOWER CURB (HALF WALL 51f1.)SCALE:3'=I'4 UPPER FLOOR PLAN - IAI It IBI ELEV. <br /> SCALE: I/4°=I'-0" <br />