My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1427 100TH ST SW 2025-03-03
>
Address Records
>
100TH ST SW
>
1427
>
1427 100TH ST SW 2025-03-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 8:42:44 AM
Creation date
1/24/2025 3:44:07 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
1427
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HUITTZOLLARS <br /> HUITT-ZOLLARS,INC. • 1102 Broadway,Suite 301 . Tacoma,WA 98402 . 253.627.9131 phone • 253.627.4730 fax . huitt-zollars.com <br /> surface (PGIS) and 1,662 SF of replaced (PGIS), but treatment is not required because the <br /> threshold of new hard surface for Minimum Requirements 6-9 is not exceeded. <br /> Table 1: Existing Conditions and Proposed Land Use i Project Area Only) <br /> Existing Conditions Proposed Conditions <br /> Land Use and Cover Area Area (AC) Area (SF) Area (AC) <br /> (SF) <br /> Asphalt Pavement 3581 0.08 4827 0.11 <br /> Landscape 4334 0.10 3266 0.08 <br /> Sidewalk 801 0.02 623 0.01 <br /> Total Area 8716 0.20 8716 0.20 <br /> Total Hard Surface 4382 0.10 7,140 0.16 <br /> Total New and Replaced HS - - 3852 0.09 <br /> Total Pervious Surface 4334 0.10 3266 0.07 <br /> Percent Hard Surface 50.3% - 81.9% - <br /> Soils <br /> According to the NRCS Web Soil Survey(see Appendix B), the soil is Alderwood-Urban land <br /> complex which is described as gravelly ashy sandy loam with a very low to moderately low <br /> infiltration rate of 0.06 in/hr. Depth to water table is about 18 to 36 inches. Note these are <br /> general attributes of the soil, which may have been altered at the site by previous grading.The <br /> characterization is considered adequate for purposes of determining the infeasibility of the <br /> infiltration-based LID BMPs. No flow control or water quality control facilities that might require <br /> more detailed soils information are required for the project. <br /> Existing Drainage System: <br /> Existing catch basins along the west edge of the park entrance drive and the west corner of the <br /> park entrance drive and 100th St SW collect entrance drive runoff and connect to an existing <br /> City 12" drain line running east-west adjacent to 1001h St SW. <br /> Fairway Estates MHC Entry Huitt-Zollars <br /> Stormwater Drainage Report December 15,2023 <br /> Everett,Washington Page 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.