My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10915 16TH AVE SE 2025-02-28
>
Address Records
>
16TH AVE SE
>
10915
>
10915 16TH AVE SE 2025-02-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 3:21:51 PM
Creation date
1/27/2025 1:44:06 PM
Metadata
Fields
Template:
Address Document
Street Name
16TH AVE SE
Street Number
10915
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A B C D E F G H I J K L M N <br /> 1 MITSUBISHI ELECTRIC TRANE HVAC US:CITY MULTI VRF OUTDOOR UNIT SCHEDULE <br /> Permit#: M2406-008 <br /> Nom System Refrig Pipe Dim Electrical-Per Module Site Address: 10915 16th Ave Se <br /> Cooling Connected Design Cooling Design Heating High/Low Corrected Corrected 208/230 or[46OV] Owner: SILVER LAKE SR HOUSING m <br /> Nominal Cooling Nominal Heating Efficiency(I)EER Heating COP @ Capacity(%of Outdoor Temp Outdoor Temp Pressure(inch) Cooling Total Heating Capacity Sound Pressure MCA 2081230 or ASSN-SILVERWOOD s <br /> System Tag Tag Reference M-NET Address Model Number Modules Capacity(BTU/h)Capacity(BTU/h) [SEER] EER2[SEER2] 47°F[HSPF] NOM) DB(T) WB(°F) (See Note 4) Capacity(BTU/h) (BTU/h) (dBA) Voltage/Phase [460V] RFS MOCP Notes/Options App.Date: 6/4/2024 <br /> 208/230V/1- Description: Evha Silverwoods Mech For Elevator <br /> CU-1 CU-1 N/A MUZ-GS09NA-Ul 9,000 10,900 15.4[27] 15.4[28.4] 4.44[12.8] 100.0% 85.0 20.3 1/4/3/8 9,405.7 6,365.9 48/50 phase 10 15 15 1,2,3,4,5 Modernization <br /> Notes&Options: ------------------------------------------------------------------------- <br /> 1 Nominal cooling capacities are based on indoor coil EAT of 80/67°F(DB/WB),outdoor of 95°F(DB) <br /> Review Status: Approved by Building,C.Bearman <br /> 2 Nominal heating capacities are based on indoor coil EAT of 70c1`IDS),outdoor of 4YF(WE) Review Date: 6/7/2024 <br /> 3 Efficiency values for EER,PER,COP are based on AHRI 1230 test method for mixture of ducted&non-ducted Indoor units. <br /> 2 4 For systems with multiple modules,refrigerant pipe dimensions indicate total system combined piping downstream of module twinning. <br /> 5 Added field charge listed is in addition to factory charge,this must be updated based upon final as-built piping layout. °z <br /> 1 Additional Permits Are Required <br /> For This Project To Include: <br /> ❑Plumbing ❑ Sprinkler <br /> ❑Mechanical ❑ Fire Alarm <br /> MITSUBISHI ELECTRIC TRANE HVAC US:CITY MULTI VRF INDOOR UNIT SCHEDULE X❑Electrical <br /> Cooling Design Heating Design Corrected Capacity Max Fan ESP <br /> Entering Temp Entering Temp Cooling Diversity Heating Diaesity Refrig Pipe Dim Peak Fan Airfiow Setting <br /> Nominal Heating DB/WB(°F)/ DB/WB(°F)/ Full/Partial(See Cooling Total Cooling Sensible Fu11/Partial(See Heating Capacity Liquid/Suction Fan Speed (Cfm)/[Design 208V/230V(IN Electrical <br /> System Tag Room Name Tag Reference Model Type Nominal Cooling Capacity(BTU/h)Capacity(BTU/h) [Water in temp] [Water in temp] Note 5,6) Capacity(BTU/h)Capacity(BTU/h) Note 5,6) (BTU/h) (inch) Setting gpm G(US)/min] WG) Voltage/Phase MCAJMFS Notes/Options ` City of Everett Permit Review <br /> MSZ-GS09NA- 208/230V/1- Powered by <br /> 3 EVERETT Status:Reviewed for Permit <br /> CU-1 FU-1 U1 Wall-Mounted 9,000 10,900 80.0/67.0 70 FULL DEMAND 9,405.7 1,977.4 FULL DEMAND 6,365.9 3/8/1. HIGH 390 phase Outdoor 1,2,3,4 ..,„,...,. <br /> Notes&options: 06/07/2024 3:23:16 PM .9 <br /> 1 Nominal cooling capacities are based on indoor coil EAT of 80/67cF(DB/WB),outdoor of 95°F(DB) ¢ <br /> 2 Nominal heating capacities are based on indoor coil EAT of 70°F IDS),outdoor of 43°F(We) J e L Z o <br /> 3 See outdoor unit schedule for outdoor ambient conditions,connected capacity,and other factors associated with corrected capacities APPROVED J e 0 <br /> Office of Community,Planning&Economic Developr. h a <br /> 4 See schematic piping/control diagram for indication of required indoor unit remote controllers,system controllers,and integration dedces. s ¢N <br /> PLANNING DEPARTMENT o= >m <br /> 5 Full demand corrected capacity includes de-rate associated with indoor vs.outdoor connected capacity indicated on outdoor unit schedule for associated system. W_r <br /> `= U$ <br /> Partial corrected capacity assumes sufficient diversity exists such that the connected capacity d NAME: Jessica Jarvie-rate does not apply. w m <br /> It is the designers responsibility to ensure"Diamond System Builderr'is set in the appropriate output capacity setting(full demand/partial demand)prior to generating this schedule. DATE: 06/14/2024 w m° <br /> 6 It is recommended to always base heating corrected capacity on full demand. O <br /> 2 <br /> 4 <br /> 0 <br /> cc <br /> Z <br /> Z <br /> O <br /> 5 U <br /> Z <br /> O Z <br /> OW <br /> 0 <br /> DO6 U) N <br /> �y � wrn <br /> CQQ <br /> H <br /> 1.11 <br /> J WOK <br /> y ULw <br /> Q 106th PI.SE L); Z <br /> 7 SCOPE OF WORK: W W <br /> FOR THE PURPOSE OF ELEVATOR MODERNIZATION: � y�St. 5E M <br /> INSTALL SPLIT UNIT HVAC FOR THE EXISTING ELEVATOR MACHINE ROOM.SIZE THE UNIT FOR <br /> PROPER CONDITIONING AND AS STATED ON THE EQUIPMENT SCHEDULES.INSTALL COMPRESSOR <br /> UNIT WALL MOUNTED ON EXTERIOR WALLAS SHOWN ON THIS PLAN. 108th St-SE <br /> AREA OF WORK UU <br /> W <br /> MECHANICAL CODE:2021 ILL a <br /> EXISTING MACH.RM. � O <br /> BASEMENT LEVEL 307.2.3(4)WATER LEVEL DETECTION AND SHUTDOWN PROVIDED IN FAN UNIT PAN n o © a <br /> ENERGY CODE:2021 0 <br /> o 8 ECONOMIZER: SECTION C403.5 EXCEPTION#11 TAKEN = w <br /> m 10915 16th Ave SE s z <br /> D <br /> KEY LEGEND AND COMPONENT LIST W <br /> J <br /> 111 St-SE a <br /> DESCRIPTION OTY PART# MANUFACTOR MOUNTING DETAILS m Z <br /> sr 4so <br /> IJ COMPRESSOR UNIT MUZGSOBNA MITSUBISHI WALL MOUNT 0 T-0"-7W <br /> INDOOR FAN UNIT MSZ-GSoBNA MITSUBISHI TAFF TO BOTTOM-23# Y. <br /> EVHA SILVERWOODS APARTMENTS - SITE PLAN FAN UNIT MICROPARTICLE FILTER MAC-EMF515F-E MITSUBISHI PM2.5 FILTER }}2t4+9 ® I—------ <br /> FAN UNIT DRAIN PAN SENSOR/CONT. SSsmE MITSUBISHI PM2.5 FILTER <br /> Y r <br /> ASSESSOR'S PARCEL#: 28051900401600 PRE-INSUL.1/4"LIQUID LINE SET lnx0GUS145)12 PD.GELCOPPER LINE HIDE WHERE EXPOSED W <br /> 112th St.SF < <br /> PLAT BLOCK: PLAT LOT: <br /> LEGAL DESCRIPTION: PRE-1NsuL.3/8^GAS LINE SET F100.GUS385012 PDM GELCOPPEfl LINE HIDE WHERE EXPOSED rj i4vEr Lake Rd. Z <br /> SEC 19 TWP 28 RGE 05 LOT 1 OF CITY OF EVE SP 1202-11-86 REC AF NO —— CONDENSATE DRAIN 13/4" crwc SURFACE MOUNT TO DRAIN W <br /> 8812020255 BEING A PTN OF NE1/4 SE1/4(EXEMPT PER ST OF WA REG O CONDENSATE PUMP Es— LIITLEa- 1 4th A— c C7 <br /> #07948-001) W <br /> LU <br /> LU <br /> APPROVED BY: <br /> ® VICINTY MAP ER <br /> DRAWN BV: <br /> 10 SCALE: NOT TO SCALE NEA <br /> DATE: <br /> 05/05/24 <br /> JOB# <br /> SILVERWOODS <br /> Dwc.No.:M-01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.