Laserfiche WebLink
Page 4 of 6 <br />C MICROMATIC°STANDARD <br />RESPONSE HORIZONTAL <br />SIDEWALL SPRINKLER <br />VK104 (K5.6) <br />The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br />Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br />Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com <br />Approval Chart 1 (UL) <br />Temperature <br />KEY <br />Micromatic° Viking Standard Response Horizontal Sidewall Sprinkler VK104 � Finish <br />For Light Hazard Occupancies Only A1X4--Escutcheon(ifapplicable) <br />Maximum 176 PSI (12 Bar) WWP <br />Sprinkler <br />Thread Size <br />Nominal K-factor <br />Overall Length <br />Listings and Approvals3 <br />Base Part <br />SIN <br />(Refer also to UL Design Criteria.) <br />Number' <br />NPT <br />BSPT <br />U.S. <br />metricz <br />Inches <br />mm <br />cULus° <br />LPCB <br />MED <br />CE8 <br />China <br />Approval <br />12995 <br />VK104 <br />1/2" <br />-- <br />5.6 <br />80.6 <br />2-1/2" <br />64 <br />A1Z, B1X, B2X, C4Z, E4Y <br />A1Z, B2Z <br />C19 <br />C1Z8 <br />12988 <br />VK104 <br />-- <br />15 mm <br />5.6 <br />80.6 <br />2-1/2" <br />64 <br />A1Z, B1X, B2X, C4Z, E4Y <br />A1Z, B2Z <br />C19 <br />C1Z8 <br />2023010 <br />1 VK104 <br />-- <br />15 mml <br />5.6 <br />80.6 <br />2-1/2" <br />64 <br />D3 <br />D3 <br />NOTICE <br />10224 <br />VK104 <br />1/2" <br />5.6 <br />80.6 <br />2-1/2"•• <br />64 <br />B2W,•B1W,A1X <br />A1Z <br />C19 <br />C1Y8 <br />C1Z9 <br />10171 <br />1 VK104 <br />1 -- <br />115 mml <br />5.6 <br />1 80.6 <br />1 2-1/2" <br />1 64 <br />1 132W, B1W,A1X <br />A1Z <br />C19 <br />C1Y8 <br />C1Z9 <br />Approved Temperature Rating Codes <br />A = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 360 °F (182 °C) <br />B = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) <br />C = 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 360 °F (182 °C) <br />D=155°F(68°C) <br />E = 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) <br />Approved Finish Codes <br />1 = Brass, Chrome, White Polyester61, and Black Polyester61 <br />2 = Wax -Coated Brass and Wax Over Polyester (corrosion resistant) <br />3 = Chrome <br />4 = ENT6 <br />Approved Escutcheon Codes <br />W = Standard surface -mounted escutcheons or recessed with the Viking Model E-1, E-2, E-3, or Model G-1 Recessed Escutcheons <br />X = Standard surface -mounted escutcheons or recessed with the Viking Model E-1, E-2, or E-3 Recessed Escutcheons <br />Y = Installed with surface -mounted escutcheons or recessed with the Viking Model E-1 Recessed Escutcheons <br />Z = Installed with surface -mounted escutcheons only <br />Footnotes <br />I. Base part number shown. For complete part number, refer to Viking's current price schedule. <br />2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. <br />3. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. <br />a. Listings and Approvals are limited to Light Hazard Occupancies where allowed by the installation standards being applied. <br />5. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. <br />s. cULus Listed as corrosion -resistant. <br />7. Other colors are available on request with the same Listings and Approvals as the standard colors. <br />e. Certified, Standard EN 12259-1, EC -certificate of conformity 0832-CPD-0021 and 0832-CPD-2003. <br />9. MED Certified, Standard EN 12259-1, EC -certificate of conformity 0832-MED-1003 and 0832-MED-1008. <br />10.Approved according to China GB standard. <br />DESIGN CRITERIA - UL <br />(Also refer to Approval Chart 1 above.) <br />cULus Listing Requirements: <br />The Micromatic° Viking Standard Response Horizontal Sidewall Sprinkler VK104 is cULus Listed as indicated in the Approval Chart for installation in accordance with <br />the latest edition of NFPA 13 for sidewall standard spray sprinklers. <br />• For use in Light Hazard occupancies only where allowed by the installation standards being applied. <br />• Locate the deflector 4" to 12" (102 mm to 305 mm) below the ceiling. <br />• Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. <br />• Minimum spacing allowed is 6 ft. (1.8 m). <br />• Align the top of the deflector parallel with the ceiling. <br />• Locate no less than 4" (102 mm) from end walls. <br />• Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. <br />• The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. <br />IMPORTANT: Always refer to Bulletin Form No. F 091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F 080614 for <br />general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking <br />technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of gov- <br />ernmental codes, ordinances, and standards, whenever applicable. <br />Form No. F_033514 19.11.18 Rev 19.4 <br />