Laserfiche WebLink
Anchor Fastening Technical Guide, Edition 21 <br />Table S — Design information, Hilt! HDI-P TZ, in accordance with CSA A23.31 <br />1+1 <br />Nominal anchor size/intemal thread dia. (n) <br />Ref <br />Setting information <br />Symbol <br />Unit <br />3/8 <br />CSA A23.3 <br />Anchor O.D. <br />d, <br />in. <br />0.561 <br />(ni <br />(14.25) <br />Effective embedment <br />h„ <br />in. <br />3/4 <br />(ni <br />(19) <br />Steel embed. material resistance factor for reinforcement <br />(P° <br />- <br />0.85 <br />8.4.3 <br />Resistance modification factor for tension, steel failure <br />R <br />- <br />0.70 <br />D.5.3 b) <br />modes <br />" <br />Min. specified yield strength <br />f„ <br />psi <br />(N/mmi <br />7,4 <br />(400 84) <br />Min. specked ultimate strength <br />f„m <br />psi <br />MiniMini(605) <br />8 <br />605) <br />Effective -cross sectional steel area in tension <br />A..N <br />in' <br />0.071 <br />(45.8 <br />Factored steel resistance in tension 4 <br />N. <br />lb <br />6,250 <br />D.6.1.2 <br />(kN) <br />(27.8) <br />Eq. D.2 <br />Concrete material resistance factor <br />1p, <br />- <br />0.65 <br />8.4.2 <br />Anchor category <br />- <br />- <br />1 <br />D.5.3 c) <br />Resistance modification factor for tension, concrete failure 3 <br />R," <br />- <br />0.60 <br />Coeff. for factored oonc. breakout resistance, uncracked <br />in -lb <br />24 <br />concrete <br />k... <br />(SI) <br />(10.0) <br />D.6.2.2 <br />Coeff. for factored oonc. breakout resistance, cracked <br />in -lb <br />17 <br />concrete <br />k�' <br />(SI) <br />(7.1) <br />D.6.2.2 <br />Modfication factor for anchor resistance, tension, <br />uncracked conc. ° <br />W4," <br />- <br />1.0 <br />D.6.2.6 <br />Critical edge distance <br />c„ <br />in. <br />6 <br />(mm) <br />(152) <br />Factored pullout resistance in 20 MPa uncracked concrete ° <br />N°,,°,,, <br />lbN/A <br />D.6.3.2 <br />(kN) <br />Factored pullout resistance in 20 MPa cracked concrete ° <br />N°,F, <br />495 <br />D.6.3.2 <br />(kN <br />j <br />Factored pullout resistance in 20 MPa cracked concrete, <br />lb <br />490 <br />seismic ° <br />Nw•p <br />(kN) <br />(2.2) <br />D.6.3.2 <br />Resistance modification factor for shear, steel failure <br />modes 2a <br />0.65 <br />D.5.3 b) <br />Factored steel resistance in shear 7 <br />V. <br />lb <br />975 <br />D7 1 2 <br />(kN) <br />(4.3) <br />Factored steel resistance in shear, seismic 7 <br />V. <br />to <br />975 <br />(kN) <br />(4.3) <br />Resistance modification factor for shear, concrete failure <br />modes 3 <br />�,v <br />- <br />0.70 <br />Coefficient for pryout resistance <br />km <br />- <br />1.0 <br />D.7.3 <br />1 Design information is taken from ICC-ES ESR-4236, dated July 2018, table 2, and converted for use with CSA A23.3 Annex D. <br />2 The HDI-P TZ is considered a brittle steel element as defined by CSA A23.3 Annex D Section D.2. <br />3 All values of R are applicable with the load combinations of CSA A23.3 Chapter 8. For concrete failure modes, no increase for Condition A is permitted. <br />4 N,,,= N„ yt, R,," where N„ tabular value above is preoalculated from A,.,, f.. <br />5 For all design cases, Wua =1.0. The appropriate effectiveness factor for cracked concrete (k,,,) or uncracked concrete (k,,,,) must be used. <br />6 For all design cases, y., =1.0. Tabular value for pullout resistance is for a concrete compressive strength of 20 MPa (2,900 psi). Pullout resistance for <br />concrete compressive strength greater than 20 MPa (2,900 psi) may be increased by multiplying the tabular pullout resistance by (A,/20)°-for MPa or <br />(f, / 2,900)69fi for psi. NA (not applicable) denotes that pullout strength does not need to be considered for design. <br />7 Shear and seismic shear tests are all performed in cracked concrete member per ICC-ES AC193 section 9.4 and 9.6 respectively. Value of V,° < 0.6 A,,,v fN <br />for all cases. Multiply V. tabular value above by yt, R,,v to get V,,, and V.,.,,. <br />Anchor Fastening Technical Guide Edition 21 13.0 ANCHORING SYSTEMS 13.3.13 HDI-P TZ FLUSH ANCHOR 433 <br />HIM, Inc. 1-800-879-80001 an mpafiol 1-800-879-50001 www.hl8l.com I HIM (Canada) Corporation I www.hlltl.ca 11-800-363-4458 <br />