Anchor Fastening Technical Guide, Edition 21
<br />Table S — Design information, Hilt! HDI-P TZ, in accordance with CSA A23.31
<br />1+1
<br />Nominal anchor size/intemal thread dia. (n)
<br />Ref
<br />Setting information
<br />Symbol
<br />Unit
<br />3/8
<br />CSA A23.3
<br />Anchor O.D.
<br />d,
<br />in.
<br />0.561
<br />(ni
<br />(14.25)
<br />Effective embedment
<br />h„
<br />in.
<br />3/4
<br />(ni
<br />(19)
<br />Steel embed. material resistance factor for reinforcement
<br />(P°
<br />-
<br />0.85
<br />8.4.3
<br />Resistance modification factor for tension, steel failure
<br />R
<br />-
<br />0.70
<br />D.5.3 b)
<br />modes
<br />"
<br />Min. specified yield strength
<br />f„
<br />psi
<br />(N/mmi
<br />7,4
<br />(400 84)
<br />Min. specked ultimate strength
<br />f„m
<br />psi
<br />MiniMini(605)
<br />8
<br />605)
<br />Effective -cross sectional steel area in tension
<br />A..N
<br />in'
<br />0.071
<br />(45.8
<br />Factored steel resistance in tension 4
<br />N.
<br />lb
<br />6,250
<br />D.6.1.2
<br />(kN)
<br />(27.8)
<br />Eq. D.2
<br />Concrete material resistance factor
<br />1p,
<br />-
<br />0.65
<br />8.4.2
<br />Anchor category
<br />-
<br />-
<br />1
<br />D.5.3 c)
<br />Resistance modification factor for tension, concrete failure 3
<br />R,"
<br />-
<br />0.60
<br />Coeff. for factored oonc. breakout resistance, uncracked
<br />in -lb
<br />24
<br />concrete
<br />k...
<br />(SI)
<br />(10.0)
<br />D.6.2.2
<br />Coeff. for factored oonc. breakout resistance, cracked
<br />in -lb
<br />17
<br />concrete
<br />k�'
<br />(SI)
<br />(7.1)
<br />D.6.2.2
<br />Modfication factor for anchor resistance, tension,
<br />uncracked conc. °
<br />W4,"
<br />-
<br />1.0
<br />D.6.2.6
<br />Critical edge distance
<br />c„
<br />in.
<br />6
<br />(mm)
<br />(152)
<br />Factored pullout resistance in 20 MPa uncracked concrete °
<br />N°,,°,,,
<br />lbN/A
<br />D.6.3.2
<br />(kN)
<br />Factored pullout resistance in 20 MPa cracked concrete °
<br />N°,F,
<br />495
<br />D.6.3.2
<br />(kN
<br />j
<br />Factored pullout resistance in 20 MPa cracked concrete,
<br />lb
<br />490
<br />seismic °
<br />Nw•p
<br />(kN)
<br />(2.2)
<br />D.6.3.2
<br />Resistance modification factor for shear, steel failure
<br />modes 2a
<br />0.65
<br />D.5.3 b)
<br />Factored steel resistance in shear 7
<br />V.
<br />lb
<br />975
<br />D7 1 2
<br />(kN)
<br />(4.3)
<br />Factored steel resistance in shear, seismic 7
<br />V.
<br />to
<br />975
<br />(kN)
<br />(4.3)
<br />Resistance modification factor for shear, concrete failure
<br />modes 3
<br />�,v
<br />-
<br />0.70
<br />Coefficient for pryout resistance
<br />km
<br />-
<br />1.0
<br />D.7.3
<br />1 Design information is taken from ICC-ES ESR-4236, dated July 2018, table 2, and converted for use with CSA A23.3 Annex D.
<br />2 The HDI-P TZ is considered a brittle steel element as defined by CSA A23.3 Annex D Section D.2.
<br />3 All values of R are applicable with the load combinations of CSA A23.3 Chapter 8. For concrete failure modes, no increase for Condition A is permitted.
<br />4 N,,,= N„ yt, R,," where N„ tabular value above is preoalculated from A,.,, f..
<br />5 For all design cases, Wua =1.0. The appropriate effectiveness factor for cracked concrete (k,,,) or uncracked concrete (k,,,,) must be used.
<br />6 For all design cases, y., =1.0. Tabular value for pullout resistance is for a concrete compressive strength of 20 MPa (2,900 psi). Pullout resistance for
<br />concrete compressive strength greater than 20 MPa (2,900 psi) may be increased by multiplying the tabular pullout resistance by (A,/20)°-for MPa or
<br />(f, / 2,900)69fi for psi. NA (not applicable) denotes that pullout strength does not need to be considered for design.
<br />7 Shear and seismic shear tests are all performed in cracked concrete member per ICC-ES AC193 section 9.4 and 9.6 respectively. Value of V,° < 0.6 A,,,v fN
<br />for all cases. Multiply V. tabular value above by yt, R,,v to get V,,, and V.,.,,.
<br />Anchor Fastening Technical Guide Edition 21 13.0 ANCHORING SYSTEMS 13.3.13 HDI-P TZ FLUSH ANCHOR 433
<br />HIM, Inc. 1-800-879-80001 an mpafiol 1-800-879-50001 www.hl8l.com I HIM (Canada) Corporation I www.hlltl.ca 11-800-363-4458