My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3433 TULALIP AVE 2025-03-28
>
Address Records
>
TULALIP AVE
>
3433
>
3433 TULALIP AVE 2025-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 7:42:14 AM
Creation date
1/27/2025 3:58:58 PM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3433
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONTRACTOR INFORMATION <br /> Oil. <br /> SUNERGYsYS AP <br /> Employee Owned N <br /> EN PHAS E IQ8M and IQ8A Microinverters SUNERGY SYSTEMS <br /> ADDRESS: 4546 LEARY WAY <br /> V4 Commonly used module pairings' w 260-460 295-500 NORTHWEST, SEATTLE, WA 98107 <br /> Module compatibility To meet compatibility,PV modules must be within max!ML m input DC voltage and maximum module I listed below. <br /> II �; Module compatibility can be checked at htt s://nphase.com/installers/microinverters/calculator PHONE NUMBER: (206) 297-0086 <br /> MPPT voltage range V 30-45 32-45 LICENSE NUMBER: SUNERS1905D4 <br /> Operating range V 16 58 <br /> JMinimum/Maximum start voltage V 22,58 LICENSE TYPE: ELECTRICAL <br /> J - Maximum input DC voltage v 6 <br /> W i _ Maximum continuous input DC current A 1 <br /> 4� Maximum input DC short-circuit current A 25 CUSTOMER INFORMATION <br /> Maximum module lw A 2 NAME: DANIEL GOODMAN <br /> Overvoltage class DC port I <br /> DC port backfeed current mA ADDRESS: 3433 TU LALIP AVENUE, <br /> PV array configuration 1 x 1 ungrounded array;no additional DC side protection req ired;AC side protection requires max 20 A per branch circuit EV E R ETT, WA 98201 <br /> OUTPUT <br /> Peak output power VA 330 366 <br /> COORDINATES: 47.971262, -122.219688 <br /> Maximum continuous output power VA 325 349 <br /> Q 8 M and 1 Q 8 A Microinverters Easy to install Nominal grid voltage(L-L) V 240,split-ph se(L-L),180• APN: 00437783001602 <br /> Lightweight and compact with Minimum and Maximum grid voltage' V 211- 64 <br /> Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- plug-and-play connectors Maximum continuous output current A 1.35 1.45 <br /> defined microinverters with split-phase power conversion capability to convert DC Power line communication(PLC) Nominal frequency Hz 6D 14.700kW DC / 11.375kW AC ROOF <br /> power to AC power efficiently.The brain of the semiconductor-based microinverter between components <br /> is our proprietary application-specific integrated circuit(ASIC),which enables Extended frequency range H: 47 68 MOUNT PV SYSTEM <br /> the microinverter to operate in grid-tied or off-grid modes.This chip is built using Faster installation with simple AC short circuit fault current over <br /> advanced 55 nm technology with high-speed digital logic and has super-fast <br /> two-wire cabling three cycles Arms <br /> response times to changing loads and grid events,alleviating constraints on battery Maximum units per 20A(L-L)branch 1 <br /> sizing for home energy systems. High productivity and reliability circuit' <br /> Produce power even when the Total harmonic distortion % < <br /> thphase grid is down* Overvoltage class AC port I I <br /> More than one million cumulative AC port backfeed current mA 3 <br /> 25 hours of testing Power factor setting 1. <br /> year limited Class II double-insulated Grid-tied power factor(adjustable) 0.85leading 0.85lagging <br /> waranty enclosure Peak efficiency % 97.8 97.7 <br /> Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability Optimized for the latest high- CEC weighted efficiency % 97.5 97 <br /> Microinverters integrate with the IQ Battery, standards with more than one million powered PV modules <br /> IQ Gateway,and the Enphase App monitoring and cumulative hours of power-on testing, Nighttime power consumption mw 6 <br /> analysis software. enabling an industry-leading limited warranty MECHANICAL DATA <br /> of up to 25 years. Microgrid-forming <br /> Ambient temperature range -40°C to 60°C(-40•F to 140•F) <br /> Complies with the latest <br /> advanced grid support** Relative humidity range 4%to 100%(condensing) <br /> ® <br /> • Remote automatic updates for DC Connector type Staubli MC4 <br /> the latest grid requirements Dimensions(H x W x D) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") <br /> Configurable to support a wide weight 11 kg(2.43lbs) <br /> range of grid profiles Cooling Natural convection-no fans <br /> Connect PV modules quickly and easily to the IQ8 Series Microinverters are UL Listed as <br /> I08 Series Microinverters that have integrated PV rapid shutdown equipment and conform Meets CA Rule 21(UL 1741-SA)and IEEE Approved for wet locations Yes <br /> MC4 connectors. with various regulations when installed 1547:2018(UL 1741-SB 3"Ed.) Pollution degree PD3 PROJECT I D AU R-1004630 <br /> according to manufacturer's instructions. <br /> Note: Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure <br /> Environmental category/UV ex osure ratio NEMA Type 6/outdoor DATE 9/27/2024 <br /> IDS Microinverters cannot be mixed together withP 9 YP <br /> 'Meets UL 1741 only when installed with IQ System Controller 2. previous generations of Enphase microinverters(IQ7 <br /> IQ8M and I08A support split-phase,240 V installations only. Series,106 Series,etc)in the same system. CREATED BY V K <br /> (1)No enforced DC/AC ratio. <br /> ®2123 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IC,and certain other marks listed at (2)Nominal voltage range can be extended beyond nominal if required by the utility. <br /> httos:/ienphase.com/trademark-usa�e�uide,ines are trademarks of Enphase Energy,Inc.in the US and other countries. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-MC4-DSH-00205-1.0-EN-US-2023-09-07 <br /> Data subject to change. IQ8MA-MC4-DSH-00205-1.0-EN-US-2023-09-07 <br /> SIGNATURE <br /> MICROINVERTER SPEC SHEET <br /> SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.