Laserfiche WebLink
Product •• • Bosch IDSCI C <br /> 4 Extended Performance Data <br /> 4.1 BOVB 18+BVA 15 <br /> :• : : Cooling <br /> Indoor Outdoor m <br /> TC 17.6 17.8 18.3 18.5 18.1 18.4 18.6 18.9 19.3 19.6 19.8 20.1 / 25.6 25.8 26.2 <br /> 65 S/T 0.91 0.96 0.99 1.00 0.65 0.85 0.96 0.97 0.40 0.58 0.75 0.93 / 0.39 0.54 0.70 <br /> kW 1.04 1.04 1.05 1.05 1.05 1.06 1.07 1.08 1.07 1.08 1.09 1.10 / 1.34 1.35 1.37 <br /> TC 17.7 18.0 18.4 18.6 18.3 18.6 18.8 19.1 19.5 19.8 20.0 20.3 / 25.2 25.5 25.8 <br /> 75 S/T 0.91 0.96 0.99 1.00 0.65 0.85 0.96 0.97 0.40 0.58 0.75 0.93 / 0.39 0.54 0.70 <br /> kW 1.20 1.21 1.22 1.22 1.22 1.23 1.24 1.25 1.25 1.26 1.27 1.28 / 1.60 1.62 1.64 <br /> TC 17.7 18.0 18.4 18.6 18.3 18.6 18.8 19.1 19.5 19.8 20.0 20.3 / 25.2 25.4 25.8 <br /> 85 S/T 0.91 0.96 0.99 1.00 0.65 0.85 0.96 0.97 0.40 0.58 0.75 0.93 / 0.39 0.54 0.70 <br /> 630 kW 1.40 1.41 1.43 1.43 1.43 1.44 1.45 1.46 1.46 1.47 1.48 1.49 / 1.77 1.78 1.80 <br /> TC 17.6 17.9 18.3 18.5 18.2 18.5 18.7 19.0 19.4 19.8 20.0 20.3 / 25.1 25.3 25.6 <br /> 95 S/T 0.91 0.96 0.99 1.00 0.65 0.85 0.96 0.97 0.40 0.58 0.75 0.93 / 0.39 0.54 0.70 <br /> kW 1.65 1.67 1.68 1.68 1.68 1.70 1.71 1.72 1.73 1.74 1.75 1.77 / 2.11 2.12 2.14 <br /> TC 17.5 17.8 18.2 18.4 18.1 18.4 18.6 18.9 19.4 19.7 19.9 20.2 / 24.8 25.1 25.4 <br /> 105 S/T 0.92 0.97 1.00 1.00 0.66 0.86 0.97 0.98 0.41 0.59 0.76 0.94 / 0.40 0.55 0.71 <br /> kW 1.93 1.94 1.96 1.96 1.95 1.97 1.99 2.00 2.01 2.02 2.04 2.05 / 2.46 2.48 2.50 <br /> TC 17.2 17.5 17.9 18.1 17.8 18.1 18.3 18.6 19.1 19.4 19.5 19.8 / 24.6 24.8 25.2 <br /> 115 S/T 0.94 0.99 1.00 1.00 0.68 0.88 0.99 1.00 0.43 0.61 0.78 0.96 / 0.42 0.57 0.73 <br /> kW 2.20 2.22 2.24 2.24 2.24 2.26 2.28 2.30 2.30 2.32 2.34 2.36 / 2.87 2.89 2.91 <br /> TC 21.8 22.1 22.6 22.9 22.5 22.8 23.0 23.3 24.1 24.3 24.5 24.8 / 30.50 30.8 31.0 <br /> 65 S/T 0.93 0.98 1.00 1.00 0.68 0.88 0.99 1.00 0.43 0.61 0.77 0.95 / 0.41 0.55 0.71 <br /> kW 1.28 1.29 1.30 1.30 1.30 1.31 1.33 1.34 1.33 1.35 1.36 1.37 / 1.74 1.76 1.78 <br /> TC 21.5 21.9 22.4 22.6 22.3 22.5 22.8 23.0 23.9 24.2 24.3 24.3 / 30.50 30.8 31.0 <br /> 75 S/T 0.93 0.98 1.00 1.00 0.68 0.88 0.99 1.00 0.43 0.61 0.77 0.96 / 0.41 0.55 0.71 <br /> kW 1.48 1.50 1.51 1.51 1.51 1.52 1.54 1.55 1.56 1.57 1.58 1.58 / 1.93 1.95 1.97 <br /> TC 21.4 21.7 22.2 22.5 22.1 22.5 22.7 23.0 23.9 24.0 24.2 24.3 / 30.2 30.5 30.6 <br /> 85 S/T 0.93 0.98 1.00 1.00 0.68 0.89 0.99 1.00 0.43 0.61 0.77 0.96 / 0.41 0.55 0.71 <br /> 850 kW 1.64 1.66 1.67 1.67 1.67 1.69 1.70 1.72 1.74 1.74 1.74 1.76 / 2.11 2.13 2.15 <br /> TC 21.2 21.6 22.1 22.2 22.0 22.3 22.5 22.9 23.5 23.7 24.0 24.2 / 30.0 30.2 30.3 <br /> 95 S/T 0.93 0.98 1.00 1.00 0.68 0.89 0.99 1.00 0.43 0.61 0.77 0.96 / 0.41 0.55 0.71 <br /> kW 1.87 1.89 1.91 1.91 1.91 1.93 1.94 1.96 1.98 1.99 1.99 2.00 / 2.52 2.53 2.54 <br /> TC 19.9 20.2 20.5 20.8 21.7 22..0 22.3 22.6 23.0 23.2 23.4 23.7 / 27.9 28.1 28.2 <br /> 105 S/T 0.94 0.99 1.00 1.00 0.69 0.90 1.00 1.00 0.44 0.62 0.78 0.97 / 0.42 0.56 0.72 <br /> kW 2.19 2.21 2.23 2.23 2.23 2.25 2.27 2.29 2.30 2.32 2.33 2.35 / 2.83 2.85 2.88 <br /> TC 19.6 19.9 20.2 20.5 21.4 21.7 22.0 22.3 22.7 22.9 23.1 23.4 / 27.6 27.8 27.9 <br /> 115 S/T 0.96 1.00 1.00 1.00 0.71 0.92 1.00 1.00 0.46 0.64 0.80 0.99 / 0.44 0.58 0.74 <br /> kW 2.51 2.53 2.54 2.56 2.56 2.58 2.63 2.65 2.67 2.69 2.71 2.73 / 3.23 3.24 3.25 <br /> TC 25.2 25.5 26.1 26.4 26.1 26.4 26.7 27.0 27.9 28.1 28.4 28.7 / 35.3 35.6 35.8 <br /> 65 S/T 0.95 0.99 1.00 1.00 0.69 0.89 1.00 1.00 0.44 0.62 0.79 0.97 / 0.42 0.55 0.71 <br /> kW 1.56 1.57 1.59 1.59 1.59 1.60 1.62 1.63 1.63 1.64 1.66 1.67 / 2.13 2.16 2.18 <br /> TC 25.1 25.4 26.0 26.3 26.0 26.3 26.6 26.9 27.8 28.1 28.3 28.6 / 34.6 34.9 35.2 <br /> 75 S/T 0.95 0.99 1.00 1.00 0.69 0.89 1.00 1.00 0.44 0.62 0.79 0.98 / 0.42 0.55 0.71 <br /> kW 1.79 1.80 1.82 1.82 1.82 1.84 1.85 1.87 1.87 1.89 1.91 1.92 / 2.30 2.33 2.35 <br /> TC 24.8 25.1 25.7 26.0 25.7 26.0 26.3 26.6 27.5 27.9 28.1 28.3 / 34.0 34.3 34.6 <br /> 85 S/T 0.95 0.99 1.00 1.00 0.69 0.90 1.00 1.00 0.44 0.62 0.80 0.98 / 0.42 0.55 0.71 <br /> 1020 kW 1.94 1.96 1.98 1.98 1.98 1.99 2.01 2.03 2.04 2.06 2.07 2.08 / 2.54 2.56 2.59 <br /> TC 24.5 24.8 25.4 25.7 25.4 25.7 26.0 26.2 27.2 27.4 27.7 27.9 / 32.7 32.8 32.9 <br /> 95 S/T 0.95 0.99 1.00 1.00 0.69 0.90 1.00 1.00 0.44 0.62 0.80 0.98 / 0.42 0.56 0.73 <br /> kW 2.26 2.28 2.30 2.30 2.30 2.32 2.35 2.37 2.38 2.39 2.41 2.43 / 2.91 2.92 2.93 <br /> TC 24.0 24.3 24.9 25.2 24.9 25.2 25.4 25.7 26.7 26.9 27.1 27.4 / 30.7 30.9 31.0 <br /> 105 S/T 0.96 1.00 1.00 1.00 0.70 0.91 1.00 1.00 0.45 0.63 0.82 1.00 / 0.43 0.57 0.75 <br /> kW 2.62 2.65 2.67 2.67 2.67 2.70 2.73 2.75 2.76 2.78 2.80 2.82 / 3.16 3.16 3.16 <br /> TC 23.4 23.7 24.3 24.5 24.3 24.5 24.8 25.1 25.7 25.9 26.2 26.4 / 28.2 28.3 28.5 <br /> 115 S/T 0.97 1.00 1.00 1.00 0.72 0.93 1.00 1.00 0.47 0.65 0.84 1.00 / 0.46 0.60 0.78 <br /> kW 2.98 3.01 3.04 3.04 3.04 3.07 3.10 3.13 3.14 3.16 3.20 3.22 / 3.26 3.26 3.27 <br /> Table 2 <br /> TC refer to total capacity S/T:refer to the ratio of sensible heat and total capacity M refer to total input power <br /> Bosch Thermotechnology Corp.112.2020 Data subject to change <br />