My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2916 47TH ST SE 2025-03-03
>
Address Records
>
47TH ST SE
>
2916
>
2916 47TH ST SE 2025-03-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 8:11:11 AM
Creation date
1/28/2025 7:57:09 AM
Metadata
Fields
Template:
Address Document
Street Name
47TH ST SE
Street Number
2916
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�® mmmoommmmmmmmmom <br /> 60 TC 38.9 38.7 38.7 38.7 38.7 38.7 38.7 38.7 38.7 38.7 38.7 38.7 37.1 34.2 32.9 31.7 <br /> kW 2.08 2.18 2.32 2.47 2.63 2.86 3.05 3.38 3.74 4.13 4.51 4.93 4.93 4.75 4.62 4.51 <br /> TC 30.6 30.4 30.4 30.4 30.4 30.4 30.4 30.4 30.4 30.4 30.4 30.4 30.4 30.4 30.4 30.4 <br /> 70 <br /> kW 1.66 1.78 1.91 2.05 2.18 2.33 2.49 2.69 2.91 3.23 3.45 3.78 4.15 4.58 4.75 4.87 <br /> 1020 <br /> TC 26.0 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 25.9 <br /> 75 <br /> kW 1.30 1.42 1.52 1.68 1.83 1.97 2.12 2.31 2.51 2.69 2.91 3.11 3.39 3.66 3.91 4.16 <br /> TC 21.6 21.5 21.5 21.5 21.5 21.5 21.5 21.5 21.5 21.5 21.5 21.5 21.5 21.5 21.5 21.5 <br /> 80 <br /> kW 1.16 1.28 1.43 1.55 1.68 1.74 1.89 2.03 2.18 2.35 2.52 2.68 2.81 2.97 3.22 3.48 <br /> TC 44.3 44.1 44.1 44.1 44.1 44.1 44.1 44.1 44.1 44.1 44.1 41.8 38.9 35.8 34.5 32.7 <br /> 60 <br /> kW 2.32 2.42 2.68 2.84 3.08 3.35 3.45 3.78 4.15 4.53 4.81 5.01 4.82 4.63 4.55 4.48 <br /> TC 35.4 35.2 35.2 35.2 35.2 35.2 35.2 35.2 35.2 35.2 35.2 35.2 35.2 34.6 33.3 31.5 <br /> 70 <br /> kW 1.94 2.04 2.23 2.37 2.52 2.68 2.82 3.01 3.31 3.65 3.85 4.18 4.53 4.93 4.86 4.78 <br /> 1150 <br /> TC 30.6 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 <br /> 75 <br /> kW 1.61 1.73 1.88 2.02 2.18 2.36 2.54 2.73 2.93 3.12 3.39 3.63 3.91 4.27 4.53 4.82 <br /> TC 25.7 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 25.6 <br /> 80 <br /> kW 1.43 1.55 1.64 1.74 1.86 2.01 2.18 2.36 2.52 2.72 2.91 3.10 3.27 3.47 3.69 3.98 <br /> 60 TC 48.6 48.4 48.4 48.4 48.4 48.4 .48.4 48.4 48.4 48.4 44.9 41.7 38.6 35.6 34.3 33.1 <br /> kW 2.77 2.87 3.12 3.37 3.71 4.07 4.32 4.60 4.91 5.34 5.15 4.97 4.78 4.63 4.56 4.50 <br /> TC 38.3 38.1 38.1 38.1 38.1 38.1 38.1 38.1 38.1 38.1 38.1 38.1 37.3 34.3 33.1 31.9 <br /> 70 <br /> kW 2.32 2.42 2.57 2.71 2.86 3.03 3.22 3.57 3.92 4.25 4.59 4.93 5.13 4.95 4.88 4.81 <br /> 1350 <br /> TC 33.0 32.9 32.9 32.9 32.9 32.9 32.9 32.9 32.9 32.9 32.9 32.9 32.9 32.9 32.1 31.2 <br /> 75 <br /> kW 1.93 2.05 2.22 2.38 2.55 2.73 2.89 3.09 3.33 3.58 3.84 4.19 4.58 4.94 5.01 4.95 <br /> TC 28.2 28.1 28.1 28.1 28.1 28.1 28.1 28.1 28.1 28.1 28.1 28.1 28.1 28.1 28.1 28.1 <br /> 80 <br /> kW 1.65 1.77 1.94 2.09 1 2.26 2.41 1 2.56 2.75 2.93 2.15 3.36 3.63 3.91 4.21 4.38 4.54 <br /> Table 17 <br /> TC refer to total capacity kW:refer to total Input power <br /> 1 Not recommended to use airflows above 1350 CFM for this combination. <br /> Data subject to change 12.2020 1 Bosch Thermotechnology Corp. <br />
The URL can be used to link to this page
Your browser does not support the video tag.