1321 COLBY AVE BASE FILE 2025-01-31
>
Address Records
>
COLBY AVE
>
1321
>
BASE FILE
>
1321 COLBY AVE BASE FILE 2025-01-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2025 1:55:21 PM
Creation date
1/28/2025 9:39:55 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIFICATIONS FOR SLO - CLOSE <br /> ALL BUTTERBALL SLO-CLOSE <br /> PATENTED INSTALLATION (BB-SC) <br /> SLO-CLOSE BUTTERBALL VALVES... A. The BBSC can be installed in any orientation in a <br /> piping system using standard National Pipe Threads. <br /> • provide slow opening and closing properties in a quarter- Wrench should be used to hex on the end of valve <br /> turn valve.The purpose is to eliminate hydraulic shock <br /> and water hammer in fire protection and other liquid being threaded to pipe.Pipe sealants should be used <br /> systems. sparingly. <br /> B. The valves with internal switches can be easily wired <br /> •are available with or without an internal, pre-wired in the field.They will have two switches, switch-1 will <br /> supervisory tamper switch assembly. When mounted on have dual leads on the terminals.This switch is to be <br /> any slo-close valve and wired,the switches signal connected to the supervisory circuit of a Listed alarm <br /> movement of the valve disc from the full open position. control panel.Switch-2 will have single leads and may <br /> •are available factory mounted to a valve or as a kit for field be connected to auxiliary equipment per direction of <br /> installation on previously installed valves. the local authority having jurisdiction. Cap any <br /> unused wire leads with wire nuts and tuck into <br /> •have switch ratings of: junction box.All connections shall be reviewed and <br /> 10 Amps/115 VAC-60 Hz approved by the local authority having jurisdiction. <br /> 0.5 Amps/28 VDC C. A 14 gage green wire has been fastened to the <br /> interior of the housing and is to be used as a housing <br /> •are equipped with tamper switch assemblies FOR ground. <br /> INDOOR AND OUTDOOR USE. <br /> D. Recommended type of wire to be used is No.16 Dual <br /> •have UL/FM ratings to 175 psi. (Also available at 350 psi Rated UL 300V 80 C and 300V 105 C. <br /> with N.Y.C.B.S.A. approval.) E. Installation must be in compliance with NFPA 72 and <br /> 13,or bonded and grounded per Canadian Electrical <br /> Code Part 1. <br /> U F. The BB-SC, BBHSC (threaded-end) and BBVSC, <br /> F M <br /> with schedule 40 and/or 80 pipe, sizes 1", 1-1/4", 1- <br /> APPROVED <br /> LISTED 1/2", 2"and 2-1/2"perASME/ANSI B36.10. <br /> For use with fire protection sprinkler systems 175psi. INSTALLATION FOR NEWYORKCITYVALVES <br /> N.Y.C. special valves have a large flow indicator which <br /> Approved by the New York City Board of Stds. & points in the direction of the valve disc,indicating open or <br /> Appeals under Calendar No. 996-81 -SM,for 175 psi and closed.The valve should be installed in a position where <br /> Calendar number 720-83-SA for 350 psi. the indicator is readily visible. <br /> MODEL DESCRIPTION SIZES <br /> BB-SC100 Valve Less Switch 175 prig-Threaded Ends NYC BSA 1", 1-1/4", 1-1/2", <br /> BB-SCS02 Valve With Switch Approved 211, 2-1/2" <br /> BBVSC100 Valve Less Switch NYC BSA <br /> 175 psig- Grooved Ends 2", 2-1/2" <br /> BBVSCS02 Valve With Switch Approved <br /> BBHSC100 Valve Less Switch 350 psig-Threaded Ends NYC BSA 1", 1-1/4", 1-1/2", <br /> BBHSCS02 Valve With Switch Approved 211, 2-1/2" <br /> BVHSC100 Valve Less Switch NYC BSA <br /> 350 psig- Grooved Ends 211, 2-1/2" <br /> BVHSCS02 Valve With Switch Approved <br /> The information presented on this sheet is correct at time of publication. Milwaukee Valve reserves the right to change design and/or materials <br /> without notice. For our Installation, Operation and Maintenance Manual and the most current product information go to www.milwaukeevalve.com. <br /> State of California Prop 65 WARNING:Cancer and Reproductive Harm. For more information visit www.p65warnings.ca.gov. <br /> Rev. 2 2 <br /> MILWAUKEE VALVE <br />