Laserfiche WebLink
INTELLIKNIGHT FIRE ALARM CONTROLPANEL <br /> SLC Detectors SLC Modules 5880 LED/10 Module <br /> 5820XL devices feature a low profile SD500-AIM Features 40 LED <br /> design and EEprom addressing. Dry contact input module for use with outputs, 8 normally a <br /> EEprom addressing prevents water normally open dry contacts. It features open dry contact <br /> intrusion problems via the back of the an indicator LED to show alarm status. inputs, and one piezo <br /> sensor and eliminates mechanical SD500-MIM output. <br /> failures related to decade switches. Mini dry contact input module is a small 5865-3 and 5865-4 <br /> SD505-APS version of the SD500-AIM. For use with Remote LED Annunciator <br /> Addressable photoelectric smoke pull stations and other normally open Features 30 programmable LED (15 <br /> detector. dry contact inputs. red and 15 yellow)outputs, and a piezo <br /> SD505-AIS SD500-ANM sounder. The 5865-4 adds a silence <br /> Addressable ionization smoke detector. Addressable notification module and reset switch to the package. <br /> SD505-AHS providing a single Class A or Class B 5883 Relay Board <br /> Absolute temperature heat detector notification circuit on the SLC. Features 10 general purpose Form C <br /> that goes into alarm immediately if the SD500-ARM <br /> relays. Used with 5880 module. <br /> temperature exceeds the Addressable relay module. Features 2 5824 Serial/Parallel Printer <br /> programmable trip point. Trip point Form C output relays. Provides Interface Module <br /> range from 1350E-150°F(0°C-370C). indicator LED to show output status. Provides one parallel and one RS-232 <br /> SD505-6AB SD500-SDM serial port for connecting a printer to <br /> Six inch base for use with detector Two-wire detector input module.Allows the 5820XL. Use to print a real-time log <br /> heads SD505-APS, SD505-AIS, and for the connection of conventional of system events, detector status <br /> SD505-AHS. 2-wire detectors on the SLC loop. reports, and event history. Interfaces <br /> SD5054AB Requires two additional wires for with building control system. <br /> Four inch base for use with detector power. Miscellaneous Accessories <br /> heads SD505-APS, SD505-AIS, and SD500-LIM 5660 Silent Knight Software Suite <br /> SD505-AHS. A short circuit isolator module for SLC (SKSS) <br /> SD505-6SB devices. When a short occurs on the User-friendly Windows software for <br /> Six-inch sounder base for use with SLC loop, it is detected as a trouble, remote programming of 5820XLs using <br /> existing sensor and base. Operates in but all SLC devices protected by the a PC. Upload and view panel account <br /> single and multi-station modes and/or isolator module continue to operate. information, event history, and detector <br /> as a system sounder. Requires 2 SD500-LED status. <br /> additional wires for power. An LED driver module capable of 5670 Silent Knight Software Suite <br /> SD505-61B driving 80 LEDs. Use up to 40 modules (SKSS) <br /> Six-inch isolator base for use with per SLC loop and up to 100 Powerful end-user facility management <br /> existing base and the SD505-APS, SD500-LED modules per system. software allows viewing of detector <br /> SD505-AIS, and SD505-AHS sensors. status and event history via modem or <br /> Provides isolation for style 7 circuits. S-BUS Accessories direct connection. <br /> SD505-6RB 5860/11 Remote Fire Annunciator Plex-1 <br /> Six-inch relay base for use with existing Features the same 80 character backlit Dead front cabinet door with clear <br /> sensor and base. Provides one Form C LCD display keypad and firefighter's window to limit access to the FACP. <br /> contact. keyswitch as the 5820XL. 5860 is gray <br /> and 5860R is red. RBB <br /> SD505-ADH Remote battery box accessory cabinet. <br /> The <br /> SL <br /> Duct housing that detects smoke in T Signal Line Circuit Expander Use if backup batteries are too large to <br /> HVAC ducts. The SLC expander is used to add more fit into FACP cabinet. Dimensions: <br /> SD505-ADHR addressable devices to the IntelliKnight 16"W x 10" H x 6" D <br /> system. 5820XL supports three Duct detector base with relay. Provides 5815XLs. Each 5815XL can support (406 mm W x 254 mm H x 152 mm D) <br /> Form C alarm contact. For use with 127 devices. SD505-DTS <br /> SD505-APS and SD505-AIS sensors. Remote test switch. Used with <br /> Compatible with SD505-DTS remote 5895XL Intelligent Power Module SD505-ADHR. Provides remote key <br /> test switch. Adds 6 amps of power, 6 Flexput 1/0 operated test function and annunciation <br /> SD500-PS/SD500-PSDA circuits and 2 Form C relay circuits to a of detector alarm. <br /> SD500-PS is a single action pull station 5820XL system. <br /> and SD500-PSDA is a dual action pull 5496 Intelligent Power Module <br /> station. A 6 amp notification power expander <br /> that provides four power-limited notifi- <br /> cation appliance circuit outputs. <br /> SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA <br /> KNIGHT keep our product information up-to-date and accurate.We cannot cover all <br /> specific applications or anticipate all requirements.All specifications are FORM#350210 Rev E,04/06 <br /> subject to change without notice. For more information,contact Silent Knight <br /> by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, MN 55369-4927. Copyright©2006 Silent Knight <br /> Phone: (800)328-0103, Fax: (763)493-6475. <br /> IntelliKnight&JumpStart are Registered Trademarks of Silent Knight <br /> Flexput is a Trademark of Silent Knight <br />