DF-60241:E•B-105 <br /> ANN-LED <br /> LED Annunciator Module FirelffeALarms <br /> by Honeywell <br /> Annunciators <br /> General <br /> The ANN-LED annunciator module provides LED annunciation of <br /> general system faults and input zones/points when used with a com- INS FaWt FaW as Fa°" <br /> patible Fire Alarm Control Panel(FACP).The ANN-LED module pro- <br /> videsEarth BFauA �Fa n` o:aoiee Maa•aa�a <br /> alarm (red), trouble (yellow) and supervisory (yellow) <br /> Fa° wNEz wNEa ®wNEa ©woes <br /> ( ) (Y ) p Y (Y ) <br /> indication for up to ten input zones or addressable points. ANN- o <br /> RLED has red LEDs only for alarm communication of up to 30 <br /> addressable points. <br /> The ANN-LED is supplied standard with certain Canadian FACPs as <br /> wNE b p 7pVE 7 p wNE 8 <br /> required by ULC. <br /> The ANN-LED and the FACP communicate over a two-wire serial <br /> interface employing the ANN-Bus communication format. An addi FIR ALARM ANNUNCIATOR <br /> - <br /> tional two wires are used for 24-volt DC power. A single four-con- <br /> ductor unshielded cable may be used for both power and data <br /> communications. <br /> Up to eight ANN-Bus devices may be connected to the ANN-Bus of Ordering Information <br /> each FACP. ANN-LED: annunciator module with alarm (red), trouble (yellow) <br /> and supervisory (yellow) indication for up to ten input zones or <br /> Features addressable points, includes module mounting bracket, metal cover <br /> • ANN-LED connects to the ANN-Bus terminal on the FACP and and clear plastic screen, rubber display/label holder, screws for <br /> requires minimal programming securing the metal cover and the backbox, red enclosure <br /> • Includes three LEDs for each zone:Alarm, Trouble and Supervi- ANN-LED-W: same as above, with gray enclosure and white key- <br /> sory. pad <br /> • Compatible with the ES-200X, ES-50X, MS-9600(UD)LS, MS- ANN-RLED: annunciator module with alarm (red) indicators for up <br /> 92000DLS, MS-9050UD, MS-5UD, MS-10UD, MRP-2001, and to 30 input zones or addressable points, includes red enclosure <br /> MRP-2002, ANN-RLED-W: same as above, with gray enclosure and white key- <br /> Can be remotely located up to 6,000 feet (1,829 m) from the pad <br /> panel <br /> • May be powered by 24 VDC from the host FACP or by remote Agency Listings and Approvals <br /> power supply(requires 24 VDC) <br /> The listings and approvals below apply to the ANN-LED. In some <br /> Specifications cases, certain modules may not be listed by certain approval agen- <br /> cies, or listing may be in process. Consult factory for latest listing <br /> • Maximum ANN-BUS Voltage:24 VDC status. <br /> • Maximum Current:Alarm: 68 mAStandby:28 mA UL: S2424 <br /> • Maximum wiring distance from FACP:6,000 ft. (1,829 m.) ULC: S2424(ANN-LED only) <br /> • Ambient Temperature: 32°F to 120°F(0°C to 49°C) FM approved <br /> • Relative Humidity:93%±2%RH (non-condensing)at 32°C±20C CSFM: 7120-0075:0222 <br /> (90OF±30F) MEA: 333-07-E <br /> • For use indoors in a dry location Fire Dept of NY: COA#6177 <br /> • Connections to FACP are power-limited and supervised <br /> • 5.160" (13.11 cm.) high x 10.043" (25.51 cm.)wide x 1.77" (4.5 <br /> cm.)deep <br /> The ANN-Bus <br /> POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- <br /> IARY POWER SUPPLY <br /> ANN-Bus devices can be powered by an auxiliary power supply <br /> when available panel power is exceeded. See FACP manual for <br /> information. <br /> ANN-BUS DEVICE ADDRESSING <br /> Each ANN-Bus device requires a unique address (ID Number) in <br /> order to communicate with the FACP.A maximum of eight devices <br /> can be connected to the FACP ANN-Bus communication circuit. See <br /> the FACP manual for more information. <br /> DF-60241:E•3/15/2018—Page 1 of 2 <br />