Laserfiche WebLink
FIRE ALARM reOMMUNICATOP <br /> -qUBMITTAL <br /> POWAR HOLDINGS , LLC ( EVERETT) <br /> everQn- <br /> 1825 B ROADWAY, EVERETT, WA 98201 <br /> 600 Oakesdale Ave. SW <br /> Suite 100 <br /> Renton,WA 98057 <br /> SCOPE OF WORK & DESIGN BASIS Antenna CONNECTORSATTHE CONNECTORSA77HE INSTALLATION&GENERAL WIRING NOTES: everonsolutions.com <br /> FIRE ALARM CONTROL PANELS I DE CLSS PATHWAY SIDE CLSS PATHWAY COMMUNICATOR GENERAL NOTES: <br /> roo vx,. <br /> SCOPE OF WORK:INSTALLATION OF NEW FIRE ALARM COMMUNICATOR. 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE <br /> .u1PVAU# WITH NFPA,LOCAL AND STATE AHJ's,NEC AND CONTRACT <br /> CAD - DRAWINGS <br /> 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT <br /> - Wall mounbngholes . - ' INTENDED FOR ACTUAL CONDUIT ROUTING. <br /> PROJECT INFORMATION g 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL <br /> / 3 CONTRACTOR PER NEC AND AHJ. <br /> INSTALLATION OF HONEYWELL HW-AV-LTE-M FIRE ALARM COMMUNICATOR(WENCLOSURE)TO r�// 4. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE ALL <br /> MONITOR FIRE-LITE MS-10UD FIRE ALARM CONTROL PANEL. RRirwun <br /> L#wEx � DEVICE PER ELECTRICAL/ARCHITECTURAL PLANS. <br /> Endosuresldeknockout sem,R,,o.,■c e- _ _ RMV62 5. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR <br /> narrows — TLPs. OPENS,SHORTS,GROUNDS AND PROPER"END-OF-LINE" <br /> _ 08 (Metal Eondultnotinnuded) aw<ER " RESISTANCE. EACH CIRCUITS METER READING MUST BE <br /> APPLICABLE CODES: ® DOCUMENTED AND PRESENTED TO THE EVERON FIELD <br /> -2021 IFC WITH WA AMENDMENTS TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP&CHECKOUT. <br /> 2019 NFPA 72 <br /> 6. AS-BUILTS: <br /> J J 6.1. A SET OF INSTALLATION AS-BUILT DRAWINGS SHOWING <br /> -2017 NFPA 70(NEC) ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT <br /> -MUNICIPAL AMENDMENTS Studs for power suppty BY PROJECT FOREMAN FOR USE BY THE EVERON <br /> {nutslncluded4 Not vsed. <br /> TECHNICIAN. <br /> -_- Figure 5-1:Y-/Iring for Uia.or:apt:.-, 6.2. AS-BUILTS SHALL BE KEPT ORDERLY AND BE CLEARLY <br /> • MARKED WITH DIFFERENT COLOR PENS FOR EACH CIRCUIT <br /> t Pathway AND/OR CIRCUIT TYPE AND LABELED PER THE WIRE LEGEND. <br /> PanelTerminal Panel Connector AS-BUILTS FINAL <br /> PROJECT CONTACT INFORMATION: Connector Connection NSTALLEDNLOCATIONSUSTpTE IF NOTANGES INSTALLED ATO THTE <br /> LOCATION DEVICE <br /> Mounting dencewith AL1X + + SHOWN ON DESIGN DOCUMENTS. <br /> he.nuts(nutsmcluded) 6.3. AS-BUILT REDLINES NOT PROVIDING THIS INFORMATION WILL <br /> CUSTOMER: BE RETURNED TRACTOR FOR <br /> POWAR HOLDINGS,LLC GND - - CORRECTION. EVERON THE hIS NAOT RESPOLLATION CN IBLE FOR THESE <br /> NAME: DELAYS. <br /> PRIMARY DIALER RING RING 7. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS <br /> ADDRESS: 10608 SE 291st St. WILL BE MADE WITH THE EVERON PROJECT MANAGER. <br /> TIP TIP 8. ALL EVERON FIELD SERVICES MUST BE SCHEDULED WITH THE Drawing Prepared/Reviewed by: <br /> EVERON PROJECT MANAGER WITH A MINIMUM OF 14 WORKING <br /> AUBURN,WA 98092-1923 DAYS ADVANCE NOTICE. <br /> BACKUP DIALER RING2 RING2 9. DO NOT INSTALL LINE VOLTAGE IN SAME CONDUIT AS POWER <br /> Daniela so <br /> CONTACT: HARLEEN KULWINDER TIP2 TIP2 <br /> LIMITED CABLES. INICET <br /> Certification <br /> PHONE: (206)787-0786 <br /> FAX: SYMBOL LEGEND Fire Alarm Systems-Level III <br /> FIRE ALARM SPECIFIC NOTES: <br /> EMAIL: powarholdings@gmail.com SYMBOLI QTY DESCRIPTION MOUNTING REQUIREMENTS SUPPLIER PART NUMBER 1. SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN 36"OF Expiration: 2028-03-01 <br /> FACU EXISTING EXISTING FIRE ALARM CONTROL UNIT N/A FIRE-LITE MS-10UD-7 ANY AIR DIFFUSER. <br /> 2. 2019 NFPA 72-17.7.1.11 REQUIRES THAT SMOKE DETECTORS <br /> FIRE ALARM / LIFE SAFETY PROVIDER: HW-AV-LTE-MW/ SHALL NOT BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION <br /> FAC 1 FIRE ALARM COMMUNICATOR MOUNT IN HW-AV-ENC HONEYWELL HW-AV-ENC CLEAN-UP. REVISIONS <br /> NAME: EVERON (SEATTLE) 2.1. ANY SMOKE DETECTORS THAT HAVE BEEN INSTALLED PRIOR <br /> AIMM 0 FIRE ALARM MONITOR MODULE 4-SQUARE DEEP JUNCTION BOX N/A N/A TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE NO. DATE REVISION <br /> ADDRESS: 600 Oakesdale Ave. SW Suite 100 Renton, WA 98057 ® 1 MULTI-VOLTAGE RELAY MODULE 4-SQUARE DEEP JUNCTION BOX POTTER PANT-1 INVOICED ONAT&M BASIS. <br /> 3. WALL MOUNTED NOTIFICATION DEVICES BACKBOX BETWEEN A _ <br /> MINIMUM OF 80"A.F.F TO A MAXIMUM OF 96"A.F.F. - BY:— <br /> NOTES: 3.1. DEVICES THAT ARE UNABLE TO BE MOUNTED WITHIN THAT <br /> 1-DEVICE SUBSCRIPT: RR=REMOVE&RELOCATE EX=EXISITNG TO REMAIN AC=ABOVE CEILING RB=RELAY BASE WP=WATERPROOF WG=WIRE GUARD RANGE MUST BE VERIFIED BY EVERON PRIOR TO <br /> PHONE: 425-486-2600 INSTALLATION. <br /> 2-CABLING SHOWN IS FOR CIRCUIT REFERENCE ONLY AND DOES NOT INTEND TO INDICATE THE EXACT PATHWAY. 3.2. SEE FLOOR PLANS FOR CANDELA RATING OF EACH DEVICE BY:— <br /> FAX: 425-486-2611 INSTALLED. <br /> 3-DEVICES SHOWN ON DRAWINGS IN GRAY SCALE ARE EXISTING DEVICES AND MAY NOT BE INCLUDED IN THIS SYMBOL LEGEND UNLESS NOTED. 4. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED ATA HEIGHT <br /> PROJECT MANAGER: EXT: 4-SET HORN/STROBE DECIBLE SETTING TO LOW FROM FACTORY SETTING OF HIGH,ONLESS OTHERWISE NOTED ON THE DRAWINGS. 5. BETWEEN <br /> VERIFY ALL SPRINKLER MONITORIING REMENTS DEVICES WITH FIRE � BY— <br /> ��// 5-ALL DEVICES WITH A WP SUBSCRIPT WILL REQUIRE THE USE OF A OUTDOOR OR WP BACKBOX. PROTECTION CONTRACTOR <br /> DESIGNER. EXT: 6. FIELD VERIFY ALL HVAC,FAN CONTROL,FIRE/SMOKE DAMPERS _ <br /> AND DUCT DETECTORS LOCATIONS WITH MECHANICAL BY. - <br /> CONTRACTOR <br /> LINE CITY: MANUFACTURE: PART#; DEVICE DESCRIPTION: STANDBY ALARM STANDBY ALARM 7. FACU SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF <br /> EVERON TECHNICIANS. - _ <br /> xo"rw,r�r xw,1rr1. o.: 0.2 0.2 8. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE BY:— <br /> ALLOWED. T-TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS <br /> ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, <br /> �wwruorws. o.: ._ POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND - - <br /> FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACU 5 BY <br /> ONLY. <br /> 8.1. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY CODES ADOPTED BY LOCAL AHJ <br /> JUNCTION BETWEEN THE FACU AND THE LAST DEVICE ON <br /> EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM 2019 NFPA 72 NATIONAL FIRE ALARM CODE <br /> CONDUCTORS(EXCEPT POWER GROUNDS)SHALL BE <br /> ­5am a., INSULATED AND COMPLETELY FREE FROM CONDUIT OR 2021 INTERNATIONAL FIRE CODE(WA) <br /> EARTH GROUNDS. SHIELDS WILL BE TIED TO GROUND ONLY 2017 NFPA 70 NATIONAL ELECTRICAL CODE <br /> AT THE FACU BY THE EVERON FIELD TECHNICIAN. <br /> ® 0 ® 9. THE SYSTEM SHALL BE MONITORED BY A U.L.LISTED <br /> MONITORING STATION BEFORE AHJ TEST. <br /> 10. AS-BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. <br /> Wwsw l <br /> EVERON REQUIRES ELECTRICAL REDLINES WITHIN 2 WEEKS <br /> PRIOR TO AHJ TESTS. <br /> ....'"°"uuri. 10.1. EACH CIRCUIT(SLC,NAC OR POWER)MUST BE CLEARLY <br /> MOUNT HERE IDENTIFIED WITH A DISTINCT COLOR AND LABELED. <br /> 10.2. EACH NAC/SPEAKER CIRCUIT MUST BE CLEARLY MARKED AS <br /> TO WHICH DEVICES ARE ON EACH CIRCUIT AND IN THE <br /> xE o ov i� °e5 ORDER THE DEVICES ARE WIRED TO COMPLETE THE <br /> CIRCUIT. <br /> 36"MINIMUM <br /> 36" 36"— <br /> °w�'�IE °rr� SMOKE DETECTORS SMOKE DETECTORS BEAM POCKET RULE OF THUMB: SMOKE DETECTORS <br /> CAN BE MOUNTED ON SHALL NOT BE MOUNTED BEAM POCKET IS>10%COILING HEIGHT MO<lJJST BE MOUNTED WITHIN <br /> SIDEWALL BETWEEN 4-12' WITHIN 36 OF AIR-DIFUSSERS &<40%OF THE BEAM SPACING 36 HORIZONALLY OF PEAK <br /> (NFPA 72) (NFPA 72) (NFPA 72) (NFPA 72) <br /> P,s AIM <br /> SMOUNT SMOKE DETECTORS WALL AUDIOVISUAL or VISUAL ONLY WALL AUDIO ONLY <br /> R FOR DOOR RE)fASE SERVICE (NFPA 72) (NFPA 72) <br /> WITHIN 60 OF DOOR <br /> (NFPA 72) <br /> MANUALLY OPERATED STATIONS: <br /> P 42'-48"(NFPA 12) <br /> 34"-48"(NFPA 101) <br /> 'D°EA° FACU FAC <br /> DEDICATED E.P. o <br /> o PREPARED BY: DM <br /> z CHECKED BY: DK <br /> WIRING LEGEND m <br /> PROJECT MANAGER: <br /> G <br /> donmakena@everonsolutions.com <br /> P = o <br /> 24V(24V POWER CIRCUIT) <br /> WIRE#14/2 AWG-FPLP POWER LIMITED CLASS'B1' DATE: 10/16/2024 <br /> PROJECT NO: 300010069 <br /> SLC(SIGNALING LINE CIRCUIT) <br /> TITLE: <br /> WIRE#16/2 AWG-FPLP POWER LIMITED CLASS'B1'NAC NFPA-72 TYPICAL DEVICE MOUNTING HEIGHTS <br /> SCALE:NONE <br /> COVER PAGE <br /> SHEET: <br /> FA-0 <br /> © 2024 Everon.All rights reserved.The product/service names listed in this document are marks and/or registered marks of their respective owners and used under license.Unauthorized use strictly prohibited. <br />