My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-282 2025-04-14
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-282
>
3003 W CASINO RD BLDG 45-282 2025-04-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2025 8:00:10 AM
Creation date
1/28/2025 10:46:14 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-282
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> 10.04 <br /> VIC-FLANGE ADAPTER NOTES <br /> The Style 744 (2 - 8750- 200 mm) design incorporates small teeth inside the key shoulder I.D.to <br /> prevent rotation. <br /> 2 FireLock Flange adapter should not be used on FireLock fittings. When wafer or lug-type valves are <br /> used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. <br /> 3 FireLock Flange adapters should not be used as anchor points fortie-rods across nonrestrained joints. <br /> Mating rubber faced flanges, valves, etc. require the use of a FireLock Flange washer. <br /> 4 Area A-B noted in the above drawing must be free from gouges, undulations or deformities of any type <br /> for effective sealing. <br /> 5 FireLock Flange adapter gaskets must always be assembled with the color coded lip on the pipe and <br /> the other lip facing the mating flange. <br /> 6 Flange Washers: FireLock Flange adapters require a smooth hard surface atthe mating flange face for <br /> effective sealing. Some applications for which the Vic-Flange adapter is otherwise well suited do not <br /> provide an adequate mating surface.In such cases,it is recom mended that a metal Flange Washer be <br /> inserted between the FireLock Flange adapter and the mating flange to provide the necessary sealing <br /> surface. <br /> Typical applications where a Flange Washer should be used are: <br /> A When mating to a serrated flange: a standard flat flange gasket should be used adjacentto the <br /> serrated flange and then the Flange Washer is inserted between the FireLock Flange adapter and the <br /> flange gasket. <br /> s When mating to a wafer valve:where typical valves are rubber lined and partially rubberfaced (smooth <br /> or not),the Flange Washer is placed between the valve and the FireLock Flange adapter. <br /> c When mating a rubber faced flange:the Flange Washer is placed between the FireLock Flange <br /> adapters and the rubber faced flange. <br /> D When mating AWWA castflanges to IPS flanges:the Flange Washer is placed between two FireLock <br /> Flanges. The hinge points must be oriented approximately 90°to each other. If one flange is not a <br /> FireLock Flange adapter(e.g.flanged valve),then a standard flat flange gasket must be placed <br /> adjacentto that flange and the Flange Washer inserted between the flange gasket and the FireLock <br /> Flange adapter. <br /> E When mating to components (valves, strainers, etc.) where the component flange face has an insert: <br /> follow the same arrangement as in Application 1. <br /> F When mating to a Series 705-W Butterfly valve, Style 744 may only be used on one side of the <br /> connection. <br /> When ordering Flange Washers,always specify product style(Style 744)and size to assure proper Range Washer is supplied. <br /> MATERIAL SPECIFICATIONS <br /> Flange Housing: Ductile iron conforming to ASTM A-536, grade 65.45-12. Ductile iron conforming to <br /> ASTM A-395, grade 65-45-15, is available upon special request. <br /> Coating: Black enamel <br /> • Optional: Hot dipped galvanized <br /> Bolts/Nuts: Supplied by installer <br /> Gasket: <br /> • Grade"E" EPDM-Type A Vic-Plus Gasket System A <br /> (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Ap- <br /> proved by Factory Mutual Research for wet and dry(oil free air) sprinkler services up to the rated work- <br /> ing pressure using the Grade"E"Type A Vic-Plus Gasket System,requiring no field lubrication for most <br /> installation conditions. <br /> A Standard gasket approved for dry pipe systems to-40°F(-40°C).Based on"typical"pipe surface conditions,supplemental lubricant <br /> is recommended for services installed below 0°F(-18°C)and for all dry pipe systems or systems to be subjected to airtests prior to being <br /> filled with water.Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has voids and/or <br /> cracks at the weld seams. <br /> This product shall be manufactured by Victaulic Company.All products to be installed in accordance with current Victaulic installation/assembly instructions. <br /> Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. <br /> 2 Style 744 FireLock Flange Adapter <br />
The URL can be used to link to this page
Your browser does not support the video tag.