My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-282 2025-04-14
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-282
>
3003 W CASINO RD BLDG 45-282 2025-04-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2025 8:00:10 AM
Creation date
1/28/2025 10:46:14 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-282
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RODS & EYE RODS &).4ISIVI4 <br /> • <br /> Fig. 146 (Formerly Afcon Fig. 650) Continuous Threaded Rod <br /> Size Range:'/4"through 1'/2"Stocked in six,ten, and twelve foot <br /> lengths. Other even foot lengths can be furnished to order. <br /> Material:Carbon steel or Stainless Steel Gr 304 <br /> ►i?fft°I((hhtfl(11ifff�irr,Gru►►+i�,�,r�u���t r - � .1,:. <br /> Threads:National Coarse(USS), rod threaded complete length. <br /> Finish:❑Plain or Zinc Plated(Hot-Dip Galvanized optional) <br /> Maximum Temperature:Zinc Plated 450°F,Stainless Steel 650°F <br /> Approvals:Complies with MSS SP-58. <br /> Ordering:Specify rod diameter and length,figure number, <br /> name and finish. <br /> Note:The acceptability of galvanized coatings at temperatures <br /> above 450°F is at the discretion of the end user. FIG. 146: <br /> DIMENSIONS(IN)•LOADS(LBS)•WEIGHTS(LBS) <br /> Rod Size Threads Max Load Weight <br /> A per Inch 650° F per Ft. <br /> Length 20 240 0.12 <br /> 3/e 16 730 0.30 <br /> VIII1111111111111111p1111111111111111111111111111N11111111111111U11111111111111111111111111111111U11111111111111111111111111111111u11111111111111111111111111111111111111111111�111111111111111111111111111111111N 11/2 13 1,350 0.53 <br /> t 5/e 11 2,160 0.84 <br /> A 3/a 10 3,230 1.20 <br /> 9 4,480 1.70 <br /> 1 8 5,900 2.30 <br /> 11/4 7 9,500 3.60 <br /> 1%/s 6 13,800 5.10 <br /> PROJECT INFORMATION APPROVAL STAMP <br /> Project: Approved <br /> Address: 0 Approved as noted <br /> Contractor: ❑Not approved <br /> Engineer: Remarks: <br /> Submittal Date: <br /> Notes 1: <br /> Notes 2: <br /> PH-1.18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.