My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7720 HARDESON RD K & H PRINTING 2025-01-31
>
Address Records
>
HARDESON RD
>
7720
>
K & H PRINTING
>
7720 HARDESON RD K & H PRINTING 2025-01-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2025 2:32:28 PM
Creation date
1/28/2025 10:51:58 AM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7720
Tenant Name
K & H PRINTING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ES-A-Deringer 30 <br /> Engineering Specification <br /> Job Name Contractor <br /> Job Location Approval <br /> Engineer Contractor's P.O. No. <br /> Approval Representative <br /> DeringerTM 30 I,l— <br /> Double Check Detector Assembly ,_. <br /> DCDA-II � 1 <br /> � r rr <br /> 211 -811 <br /> The DeringerTM 30 Double Check Detector assembly prevents • • "' <br /> non-health hazard pollutants from entering a potable water <br /> supply system when backpressure and/or backsiphonage Approved for Fire Protection,Waterworks,Plumbing, <br /> conditions occur.Used primarily on fire sprinkler systems when <br /> monitoring of unauthorized water use is required. and Irrigation Applications <br /> Features shall Include a meter registering either gallons or cubic feet, a <br /> single check valve, and required test cocks.The assembly shall <br /> • Integral shutoff valves for indoor or outdoor application be serviceable without special tools and approved for both <br /> • 100%stainless steel housing horizontal and vertical applications. <br /> • Tamper-resistant test cocks Materials <br /> • Patented Dual-actionT"'check modules <br /> - Poppet action at low flow Valve Housing: 304 Stainless Steel <br /> -Swing action at high flow Valve Cover: 304 Stainless Steel <br /> • Lead Free`Bronze bypass components SOV Disks: EPDM/304SS <br /> • CuFt or gallons bypass meter SOV Shafts: 304 Stainless Steel <br /> • DCDA-II single check bypass Bypass Spring 302 Stainless Steel <br /> • Silicone elastomer check discs SOV Bearings: PTFE Fluoropolymer/Bronze <br /> Non-wetted Bolts: Grade 8 Zinc Plated <br /> • Prewired supervisory switches Check Disks: Silicone(NSF) <br /> • Flange adapters available Wetted Fasteners: 18-8 Stainless Steel <br /> • IPS grooved ends Bypass Components: Lead Free Bronze <br /> Check Springs: 17-7 Stainless Steel <br /> Specification Check Pins: 17-7/18-8 Stainless Steel <br /> The Deringer 30 Double Check Detector assembly shall use Check Seats: Noryl®Polymer(NSF) <br /> two independent Dual-action check modules and two integral 0-rings: Buna-N(NSF) <br /> resiliently seated shutoff valves,all of which shall be contained Bypass Internals: ABS Polymer(NSF) <br /> within a single rigid valve housing constructed entirely of 304 pressure — Temperature <br /> stainless steel. Both integral shutoff valves shall include prewired <br /> supervisory tamper switches contained within a weatherproof Temperature Range:33°F—140°F <br /> actuator housing approved for both indoor and outdoor use. Working Pressure: 10—175 psi <br /> The Dual-action check modules shall operate as a"poppet <br /> style"check under low flow conditions,operate as a"swing <br /> style"check under high flow conditions,and use replaceable <br /> silicone elastomer sealing discs.The assembly test cocks shall The information contained herein is not <br /> be handle-less and operate by a tamper resistant actuator.The intended to replace the full product <br /> assembly shall have a single full access service port and cover installation and safety information <br /> with an in-line replaceable elastomer seal.The bypass assembly available or the experience of a trained <br /> product installer.You are required <br /> to thoroughly read all installation <br /> 'The wetted surface of this product contacted by consumable water contains less instructions and product safety <br /> than 0.259u of lead by weight. information before beginning the <br /> Noryl is a registered trademark of SHPP Global Technologies B.V. installation of this product. <br /> Ames Fire&Watmnwrks product spedlkations In U.S.customary ur&and mebk are apprordmate and are provided for reference only.For precise measure A M E <br /> ments,please contact Ames Fire&Watenvoft Tectaical Service.Ames Fire&Watenxxks reserves the right to d"or modify product design,construction, FI R E&WATER W o RK5 <br /> specificagons,or materials vdthout prior notice and vAthout barn*any obligation to make such dranges and modifications on Ames Fire&Watemorks products <br /> prevlousy or subseque W sold. A WARS Brand <br />
The URL can be used to link to this page
Your browser does not support the video tag.