My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-36 2025-03-25
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-36
>
3003 W CASINO RD BLDG 40-36 2025-03-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 3:04:37 PM
Creation date
1/28/2025 11:09:01 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-36
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
153
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10.04 <br />VIC-FLANGE ADAPTER NOTES <br />1 The Style 744 (2 - 8'750 - 200 mm) design Incorporates small teeth Inside the key shoulder I . to <br />prevent rotation. <br />z FireLock Flange adapter should not be used on FireLock fittings. When wafer or lug -type valves are <br />used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. <br />a FireLock Flange adapters should not be used as anchor pointsfortie-rodsacross nonrestrainedjoints. <br />Mating rubber faced flanges, valves, etcrequire the use of a FireLock Flange washer. <br />a Area A-B noted in the above drawing must be free from gouges, undulations or deformities of any type <br />for effective sealing. <br />s FireLock Flange adapter gaskets must always be assembled with the color coded lip on the pipe and <br />the other lip facing the mating flange. <br />6 Flange Washers FireLock Flange adapters require a smooth hard surface at the mating flange face for <br />effective sealing. Some applications for which the Vic -Flange adapter is otherwise well suited do not <br />provide an adequate mating surface. In such cases, it is recommended thata metal Flange Washer be <br />inserted between the FireLock Flange adapter and the mating flange to provide the necessary sealing <br />surface. <br />Typical applications where a Flange Washer should be used are <br />w When mating to a serrated flange a standard flat flange gasket should be used adjacent to the <br />serrated flange and then the Flange Washer is inserted between the FireLock Flange adapter and the <br />flange gasket. <br />s When mating to a wafervalve.where typical valves are rubber lined and partially rubberfaced(smooth <br />or not), the Flange Washer is placed between the valve and the FireLock Flange adapter. <br />c When mating a rubber faced flange the Flange Washer is placed between the FireLock Flange <br />adapters and the rubber faced flange. <br />D When mating AWWA cast flanges to IPS flanges. the Flange Washer is placed between two FireLock <br />Flanges. The hinge points must be oriented approximately 90' to each other. If one flange is not a <br />FireLock Flange adapter (e.g. flanged valve), then a standard flat flange gasket must be placed <br />adjacent to that flange and the Flange Washer inserted between the flange gasket and the FireLock <br />Flange adapter. <br />e When mating to components (valves, strainers, etc ) where the component flange face has an Insert. <br />follow the same arrangement as in Application 1. <br />F When mating to a Series 705-W Butterfly valve, Style 744 may only be used on one side of the <br />connection. <br />When ordering Flange Washers, always specify product style (Style 744) and size to assure proper Flange Washer is supplied <br />MATERIAL SPECIFICATIONS <br />Flange Housing. Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to <br />ASTM A-395, grade 65-45-15, is available upon special request. <br />Coating: Black enamel <br />• Optional: Hot dipped galvanized <br />Bolts/Nuts: Supplied by installer <br />Gasket: <br />• Grade "E" EPDM - Type A Vic -Plus Gasket System A <br />(Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Ap- <br />proved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated Work- <br />ing pressure using the Grade "E" Type A Vic -Plus Gasket System, requiring no field lubrication for most <br />installation conditions. <br />A Standard gasket approved for dry pipe systems to -400F T400C). Based on `typical" pipe surdce conditions, supplemental lubricant <br />is recommended for services insta Iled below 0° F (-18°C) and for a II d ry pipe systems or systems to be subjected to a it tests prior to being <br />filled with water. Su p p lementa I lubrication maya Iso be rquire d on pipe with raised or undercutwe Id sea ms or pipe that has voids and/or <br />cracks at the weld seams. <br />This product shall be manufactured by actau lic Company. All products to be installed in accordance with current actaulic installation/assembly instructions. <br />Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. <br />Style 744 FireLock® Flange Adapter <br />
The URL can be used to link to this page
Your browser does not support the video tag.