Laserfiche WebLink
STRENGTH DESIGN INFORMATION <br />ANCHORS A FASTENERS <br />STRENGTH DESIGN <br />Tension Design Information for Power -Stud+ SD2 in Concrete' I' COD1s ESR 2502 IS <br />Anchor Diameter (inch) <br />Design Characteristic <br />Notation <br />UnitsNominal <br />1& 1 5/8 <br />Anchor category <br />1,2 or 3 <br />- 1 1 1 1 <br />Minimum nominal <br />IT- <br />in. 2-3/8 <br />-3/4 <br />3-7/8 <br />4-7/8 <br />4-1/2 <br />5-3/4 <br />embedment depth' <br />(mm) (60) <br />451)(83) <br />(95) <br />(98) <br />(124) <br />(114) <br />(146) <br />Effective embedment <br />hpr <br />in 200 <br />00 <br />3.25 <br />3.25 <br />4.25 <br />3.75 <br />5.00 <br />(mm) (51) <br />(83) <br />(108) <br />(95) <br />(127) <br />STEEL STRENGTH IN TENSION (ACI 318-19 17.6.1, ACI 318-14 17.4.1 or ACI 318-11 0.5.1), <br />Minimum specified yield strength (neck) <br />to <br />Doi <br />96.0 <br />85.0 <br />85.0 <br />70.0 <br />(Ni <br />(662) <br />(586) <br />(586) <br />(483) <br />Minimum specified ultimate tensile strength (neck) <br />fpw <br />Doi <br />(Ni <br />1200. <br />(827) <br />106.0 <br />(731) <br />106.0 <br />(731) <br />90.0 <br />(620) <br />Effective tensile stress area (neck) <br />A. N <br />in' <br />0.0552 <br />0.1007 <br />0.1619 <br />0.2359 <br />(mm <br />(35.6) <br />(65.0) <br />(104.5) <br />(153.2) <br />Steel strength in tension` <br />Ni <br />IF <br />6,625 <br />10,445 <br />13,080 <br />21,230 <br />(kN) <br />(29.4) <br />(46.5) <br />(58.2) <br />(94.4) <br />Reduction factor for steel strength' <br />- <br />0.75 <br />CONCRETE BREAKOUT STRENGTH IN TENSION (ACI 318-19 17.6.2, ACI 318-14 17.4.2 or ACI 318-11 0.5.2)8 <br />Effectiveness factor for uncracked concrete <br />kpa <br />- <br />24 <br />24 <br />24 <br />24 <br />Effectiveness factor for cracked concrete <br />ka <br />- <br />17 <br />17 <br />17 <br />17 <br />Modification factor for cracked and uncracked concretes <br />Wp,N <br />- <br />1.0 <br />See <br />1.0 <br />See note 6 <br />1.0 <br />See note 6 <br />1.0 <br />See note 6 <br />note 6 <br />Critical edge distance (uncracked concrete only) <br />cep <br />(n <br />See Installation Table <br />Critical edge distance for topside of concrete -filled <br />steel deck assemblies won minimum topping thickness <br />cahck,xp <br />In. <br />See Anchor Setting Information Table for top of concrete -filled steel deck assemblies <br />(uncracked concrete only) <br />(mm) <br />with minimum topping thickness <br />Reduction factor for concrete breakout strength' <br />- <br />0.65 (Condition B) <br />PULLOUT STRENGTH IN TENSION (ACI 318-19 17.6.3, ACI 318-14 17.4.3 or ACI 318-11 0.5.3y <br />Characterlstc pullout strength, <br />Np, <br />IF <br />2,775 <br />See <br />6,615 <br />See <br />See <br />See <br />See <br />uncracked concrete (2,500 psi)' <br />(kN) <br />(12.3) <br />note 8 <br />(29.4) <br />note 8 <br />note 8 <br />note 8 <br />note 8 <br />Characteristic pullout strength, <br />Np <br />IF <br />2,165 <br />See <br />1 <br />4,375 <br />See <br />See <br />See <br />7,795 <br />cracked concrete (2,500 psi)' <br />(kN) <br />(9.6) <br />note 8 <br />(19.5) <br />note 8 <br />note 8 <br />note 8 <br />(35.1) <br />Reduction factor for pullout strength' <br />- <br />0.65 (Condition B) <br />PULLOUT STRENGTH IN TENSION FOR SEISMIC APPLICATIONS (ACI 318-19 17.10.3, ACI 318-14 17.2.3.3 or ACI 318-11 0.5.3.3.3)' <br />Characteristic pullout strength, seismic (2,500 psi)''° <br />No, <br />IF <br />(kN) <br />2,165 <br />(9.6) <br />See <br />note 8 <br />4,375 <br />(19.5) <br />See <br />note 8 <br />See <br />note 8 <br />See <br />note 8 <br />7,795 <br />(35) <br />Reduction factor for pullout strength' <br />- <br />0.65 (Condition B) <br />concrete <br />bViin <br />865,000 <br />717,00 <br />569,000 <br />420,000 <br />Mean axial stiffness values <br />(kN/mm) <br />(151) <br />(126) <br />(100) <br />(74) <br />service load range" <br />FUnccacked <br />concrete <br />bfAn <br />49,500 <br />57,000 <br />64,500 <br />72,000 <br />(kN/mm) <br />(9) <br />(10) <br />(11) <br />(13) <br />1. The data in this table is intended to be used with the design provisions of Ad 318 (-19 or-14) Chapter 17 or Ad 318 Appendix D, as applicable, for anchors resisting seismic load <br />combinations the additional requirements of Ad 318-19 17.10, ACI 318-1417.23 or Ad 318 D 3.3, as applicable, shall apply. <br />2. Installaton must comply with published instructors and details. <br />3. Al values of Owere determined horn the Toad combinatons of IBC Secton 1605.2, Ad 318 (-19 or-14)-Section 53 or Ad 318-11 Section 9.2, as applicable. If the Toad combinatons ofACI <br />318-11 Appendix C are used, then the appropriate value of 0 must be determined In accordance with ACI 318-11 D.4.4. For reinforcement that meets ACI 318 (-19 or-14) Chapter 17 or <br />ACI 318 Appendix D, as applicable, requirements for Condlton A, see ACI 318-19 17.5.3, ACI 318-1417.3 3 or Ad 318-11 D.4.3, as applicable, for the appropriate 0 factor when the load <br />combinations of IBC Section 1605.2, ACI 318 (-19 or-14) Secton 5.3 or Ad 318-11 Section 9.2, as applicable, are used. <br />4. The Power -Stud+ SD2 is considered a ductle steel element in tension as defined by Ad 318 (-19 or-14) 23 or Ad 318 D.1, as applicable. <br />5. Tabulated values for steel strength in tension are based on test results per ACI 355.2 and must be used for design in lieu of calculaton. <br />6. For all design cases use qku - 1.0. Select appropriate effectiveness factor for cracked concrete R< or uncracked concrete du.. <br />7. For all design cases use W,p - 1.0. For concrete compressive strength greater than 2,500 psi, Npn - (pullout strength value hour table)'(spedted concrete compressive an ength/2500)^ For <br />concrete over steel deck the value of 2500 must be replaced with the value of 3000 in the denominator. <br />For all anchors n - 1/2 with the exception of the 3/8" anchor size for cracked concrete where n - 1/3. <br />8. Pullout strength does not control design of indicated anchors. Do not calculate pullout strength for indicated anchor size and embedment. <br />9. Anchors are permitted to be used In lightweight concrete provided the modurcation factor equal to 0.8A is applied to all values of Pc affectng Nn and w. A shall be determined In <br />accordance with the corresponding version ofACI 318. <br />10. Tabulated values for charactenstc pullout strength in tension for seismic applications are based on test results per ACI 355.2, Secton 9.5. <br />11. Mean values shown, actual stffness vanes considerable depending on concrete strength, loading and geometry of applicaton. <br />12.Anchors are permitted for use in concrete filled steel deck door and roof assemblies, see Installaton Details A, B, C and D. <br />vvvvw.DIEWAMoom <br />