My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-36 2025-03-25
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-36
>
3003 W CASINO RD BLDG 40-36 2025-03-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 3:04:37 PM
Creation date
1/28/2025 11:09:01 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-36
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
153
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TOLBraceTM Seismic Bracing Calculations V8.8.124 <br />Contractor: Viking Automatic Sprinkler C <br />Project Address: Boeing 40-36 FSI/MIC Address: 3434 1 st Avenue S <br />* <br />E <br />Seattle, WA, 98314 .y <br />3003 W Casino Rd Phone: 206-622-4656 Po".nng6usulessWorfdmde <br />Everett, WA Licence: VI-KI-NA-S373NT <br />Job # WSC-3046 Calculations based on 2016 NFPA Pamphlet #13 <br />Brace Information <br />TOLCOTM Brace Components <br />TOLCOTM Component Listed Load Adjusted Load <br />Maximum Brace Length 7' 0" (2.134 m) <br />Diameter of Brace 1 <br />Fig. 4L Clamp 1630 Ibs (739 kg) 1411 Ibs (640 kg) <br />Fig.980 - 1/2" Universal SWIVE 3750 Ibs (1701 kg) 3247 Ibs (1473 kg) <br />Type of Brace Sch.40 <br />See Fastener Information <br />Angle of Brace 75° Min. <br />*Calculation Based on CONCENTRIC Loading <br />*Please <br />Note: These calculations are for TOLCOTM components only. Use of any <br />other components voids these calculations and the listing of the assembly. <br />Least Rad. of Gyration 0.42" (11 mm) <br />Seismic Brace Assembly Detail <br />L/R Value 200 <br />Max Horizontal Load 1604 Ibs (728 kg) <br />TOLCO FIG.980 <br />� <br />Other Requirements - FM Approved Loads <br />BRACE PIPE <br />Fastener Information <br />Orientation to Connecting Surface NFPAType F <br />Fastener <br />Type 1/2in. Unfinished Steel Bolt <br />TOLCO FIG. 4L <br />Diameter 1/2in. <br />Length N/A <br />Maximum Load 2850 Ibs (1293 kg) <br />fl <br />Brace Identification on Plans Long 6" <br />Prying Factor N/A <br />Brace Type Lateral [ ] Longitudinal [X] 4-Way [ ] <br />Sprinkler System Load Calculation (Fpw = CpWp) <br />C = 0.643 <br />Diameter <br />Type Length <br />Total Length <br />Weight Per Unit Length <br />Total Weight <br />6" (150 mm) <br />Sch. 40 31 ft (9.4 m) <br />31 ft (9.4 m) <br />31.69 lb/ft (47.16 kg/m) <br />982 Ibs (445 kg) <br />4" (100 mm) <br />Sch. 40 4.125 ft (1.3 m) <br />4.125 ft (1.3 m) <br />16.4 lb/ft (24.41 kg/m) <br />68 Ibs (31 kg) <br />2" (50 mm) <br />Sch. 40 99.5 ft (30.3 m) <br />99.5 ft (30.3 m) <br />5.13 lb/ft (7.63 kg/m) <br />510 Ibs (231 kg) <br />WASHINGTON STATE <br />■ <br />CERTIFICATE OF COMPETENCY <br />FIRE PROTECTION SPRINKLER SYSTEMS i <br />Lucia S. Y. Fung �- <br />4626-0311-C Level3 <br />Viking Automatic Sprinkler Company <br />■ VIKINAS3 NT■ <br />■ O ■ <br />■ <br />■ fuplrN <br />L Big— <br />"'". <br />GvaakAor �0.3rMB2t <br />Subtotal Weight <br />1560 Ibs (708 kg) <br />Wp (incl. 15%) <br />1794Ibs (814 kg) <br />Main Size Type/Sch. Spacing (ft) <br />Total (Fpw) <br />1154 Ibs (523 kg) <br />6" Sch. 40 31 <br />Maximum Fpw per 9.3.5.5.2 (if applicable) <br />N/A <br />fTOLBrace- Version 81 Use of TOLBraceTM is subject to terms and conditions per the end user license agreement <br />
The URL can be used to link to this page
Your browser does not support the video tag.