Anchor Fastening Technical Guide, Edition 19 <br /> Table 11 - Hilti KWIK HUS-EZ I and KWIK HUS-EZ E carbon steel screw anchor factored resistance <br /> with concrete/pullout failure in uncracked concrete',2,3,4,5 <br /> Tension-N Shear-V <br /> f'�=20 f'�=25 f =30 f'c=40 f'�=20 f'�=25 f'�=30 f'�=40 <br /> Nominal Strength Concrete Pullout MPa MPa MPa MPa MPa MPa MPa MPa <br /> anchor Effective Nominal Effec- Reduction material Strength (2,900 (3,625 (4,350 (5,800 (2,900 (3,625 (4,350 (5,800 <br /> diameter embed. embed. tiveness Factor resistance (2500 psi psi) psi) psi) psi) psi) psi) psi) psi) <br /> in. in.(mm) in.(mm) Factor Tension factor concrete) lb(M) lb(kN) lb(kN) lb(M) lb(kN) lb(kN) lb(kN) lb(kN) <br /> 1.18 1-5/8 1305 665 710 750 820 805 900 985 1,135 <br /> 10 0.75 0.65 <br /> 1/4 (30) (41) (5.8) 1 (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) <br /> 1.92 2-1/2 2350 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 <br /> (49) (64) 10 1 0.65 (10.5) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) <br /> 1.54 2-1/8 1,595 1,785 1,955 2,260 1,595 1,785 1,955 2,260 <br /> 3/8 10 1 0.65 N/A <br /> (39) 1 (54) 1 (7.1) 1 (7.9) 1 (8.7) (10.0) (7.1) (7.9) (8.7) (10.0) <br /> Table 12- Hilti KWIK HUS-EZ I and KWIK HUS-EZ E carbon steel screw anchor factored resistance ' <br /> with concrete/pullout failure in cracked concrete'2,1,4,1 <br /> Tension-Nr Shear-Vr <br /> f�=20 f'�=25 f'�=30 f'c=40 f =20 f'c=25 f.=30 f'c=40 <br /> Nominal Strength Concrete Pullout MPa MPa MPa MPa MPa MPa MPa MPa <br /> anchor Effective Nominal Effec- Reduction material Strength (2,900 (3,625 (4,350 (5,800 (2,900 (3,625 (4,350 (5,800 <br /> diameter embed. embed. tiveness Factor resistance (2500 psi psi) psi) psi) psi) psi) psi) psi) psi) <br /> in. in.(mm) in.(mm) Factor Tension factor concrete) lb(kN) lb(kN) lb(kN) I (kN) lb(kN) lb(kN) lb(kN) lb(kN) <br /> (mm) (mm) (mm) kcr R mc (N/mm� 20 25 30 40 20 25 30 40 <br /> 1.18 1-5/8 665 340 360 385 415 565 630 690 795 <br /> 7 0.75 0.65 <br /> 1/4 (30) (41) (3.0) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) <br /> 1.92 2-1/2 1165 815 910 1,000 1,155 1,800 1,740 1,910 2,205 <br /> 7 1 0.65 <br /> (49) (64) (5.2) (3.6) (4.1) (4.4) (5.1) (8.0) (7.7) (8.5) (9.8) <br /> 3/8 7 1 0.65 N/A <br /> 1.54 2-1/8 1,120 1,250 1,370 1,580 1,120 1,250 1,370 1,580 <br /> (39) 1 (54) 1 (5.0) (5.6) (6.1) (7.0) (5.0) (5.6) (6.1) (7.0) <br /> 1 See section 3.1.8 to convert design strength value to ASD value. <br /> 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. <br /> 3 Apply spacing,edge distance,and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. <br /> The lesser of the values is to be used for the design. <br /> 4 Tabular values are for normal weight concrete only.For lightweight concrete multiply design strength by A.as follows: <br /> for sand-lightweight,A.=0.68;for all-lightweight,Aa =0.60 <br /> 5 5 Tabular values are for static loads only.Seismic design is not permitted for uncracked concrete.For seismic tension loads,multiply <br /> cracked concrete tabular values in tension by the following reduction factors: <br /> 1/4-in diameter by 1-5/8-in nominal embedment depth-aN5e1S=0.60 <br /> 1/4-in diameter by 2-1/2-in nominal embedment depth-aN5e1S=0.75. <br /> No reduction needed for seismic shear.See section 3.1.8 for additional information on seismic applications. <br /> Anchor Fastening Technical Guide Edition 19 13.0 ANCHORING SYSTEMS 1 3.3.7 KWIK HUS-EZ I AND KWIK HUS-EZ E CARBON STEEL SCREW ANCHOR 343 <br /> Hilti,Inc.(U.S.)1-800-879-8000 1 en espanol 1-800-879-5000 1 www.hilti.com I Hilti(Canada)Corporation I www.hilti.com 1 1-800-363-4458 <br />