Laserfiche WebLink
Section 2. Unit Location Considerations <br /> 2.1 Unit Dimensions and Weight <br /> Table 2.1 <br /> Unit Dimensions and Weight <br /> Models H x D x W(in) Weight'(lb) / <br /> 4TWX5018N 38 x 30 x 33 174 <br /> 4TWX5024N 38 x 30 x 33 174 <br /> 4TWX503ON 35 x 30 x 33 172 <br /> 4TWX5042N 52 x 34 x 37 2477 �� H <br /> 4TWX5048N 52 x 34 x 37 270 ���ffl NN�4TWX506ON 52 x 34 x 37 270 � <br /> ��o� Is <br /> Weight values are estimated. P <br /> When mounting the outdoor unit on a roof, be �W � �ON� <br /> sure the roof will support the unit's weight. <br /> Properly selected isolation is recommended to D <br /> alleviate sound or vibration transmission to the <br /> building structure. <br /> 2.2 Refrigerant Piping Limits <br /> 1. The maximum length of refrigerant lines <br /> from outdoor to indoor unit should NOT <br /> exceed sixty (60) feet. <br /> 2. The maximum vertical change should not <br /> k <br /> exceed sixty(60) feet". Standard <br /> Line Set <br /> 60'Max <br /> � . <br /> 3. Service valve connection diameters are Line Length <br /> shown in Table 5.1. <br /> Note: For line lengths greater than sixty (60) liege <br /> feet, Refer to Refrigerant Piping Application ���� 60 <br /> Guide, SS-APGO06-EN or Refrigerant Piping � � Vertical <br /> Software Program, 32-3312-03 or latest revi- change <br /> sion). <br /> to <br /> s0' <br /> Max <br /> Vertical <br /> Change <br /> 18-BC108D1-1 B-EN 3 <br />