Laserfiche WebLink
POWER CABINET PANEL S C H E D U L E PANEL P P—1 D NOT SCALE DRAWINGS.CONTRACTOR MUSE VERIFY ALL <br /> DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR <br /> OMISSIONS.NO VARIATIONS TE MODIFICATIONS TO WORK <br /> GATE SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN <br /> BUS VA LOAD WIRE GND COND AMPS BUS AMPS COND GND WIRE LOAD BUS VA APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE <br /> A B A B A B SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND <br /> SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON <br /> HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD <br /> FENCE POST 2792 ANDREW PDU/GATT CABINET #6 #8 2" 40 1 2 60 1" #10 #6 SURGE ARRESTOR 0 REVIEW OF THIS PR EGT BE PROVIDING CONSTRUCTION <br /> EXOTHERMIC WELD TO 2792 RECTIFIERS ** 3 4 0 <br /> FENCE POST (IF SUITABLE) 2792 ANDREW PDU/GATT CABINET #6 #8 2" 40 5 6 20 1/2" #12 #12 TELCO GFI RECEPTACLE 180 <br /> GATE JUMPER #2 AWG WELDING 2792 RECTIFIERS ** 7 8 20 1/2" #12 #12 TELCO CABINET FAN 180 PAC E CC) <br /> 2792 ANDREW PDU/GATT CABINET #6 #8 2" 40 9 10 20 1/2" #12 #12 EXTERIOR LIGHT 332 ` ' `V <br /> FINISHED GRADE 2792 RECTIFIERS ** 11 12 - - - - SPACE - Y �� `v r'�� O <br /> 2792 ANDREW PDU/BATT CABINET #6 #8 2" 40 13 14 - - - - SPACE - <br /> T r <br /> I I 2792 RECTIFIERS ** 15 16 - - - - SPACE <br /> I I <br /> SPACE - - - - 17 18 - - - - SPACE - I <br /> #2 AWG TINNED SOLID #2 AWG TINNED SOLID <br /> COPPER WIRE -EXTEND TO COPPER WIRE CADWELD TO - SPACE - - - - 19 20 - - - - SPACE - <br /> OPPOSITE FENCE POST EXTERIOR GROUND RING <br /> 180 RECEPTACLE INSIDE PDU CABINET ** #10 #10 2" 20 21 22 - - - - SPACE - 422 7 <br /> 3/4"x10' GROUND ROD 180 RECEPTACLE INSIDE BATTERY CABINET ** #10 #10 2" 20 23 24 - - - - SPACE �6. STE <br /> SPACE - - - - 25 26 - - - - SPACE <br /> G - SPACE - - - - 27 28 - - - - SPACE - <br /> 24"x36" SCALE: NOT TO SCALE TYPICAL GATE GROUNDING DETAIL rj - SPACE - - - - 29 30 - - - - SPACE - <br /> 11"x17" SCALE: NOT TO SCALE <br /> SPACE - - - - 31 32 - - - - SPACE - <br /> SPACE - - - - 33 34 - - - - SPACE _ CONSTRUCTION <br /> SPACE - - - - 35 36 - - - - SPACE - <br /> SPACE - - - - 37 38 - - - - SPACE - <br /> - <br /> FENCE FABRIC SPACE - - - - 39 40 - I - I - - SPACE - <br /> ggiil SPACE - - - - 41 42 - I - I - - SPACE - <br /> FENCE POST TOTAL VA: BUS A 11860 BUS B 11528 CONNECTED VA:23388 AMPERES: BUS A 99 BUS B 96 TOTAL 97 <br /> #2 AWG TINNED SOLID <br /> RATED VOLTAGE: ❑ 120/208 0 120/240 ❑ 277/480 1 PHASE, 3 WIRE BRANCH POLES ❑12 ❑18 ❑20 1124 ❑30 1136 42 0 O6/14/18 FINAL CONSTRUCTION <br /> BARE COPPER WIRE RATED AMPS: ❑ 100 0 200 ❑ 400 CABINET: 0 SURFACE ❑ FLUSH A 03/22/18 ISSUED FOR REVIEW <br /> EXOTHERMICALLY WELDED <br /> TO EXTERIOR GROUND RING FULL NEUTRAL BUS GROUND BUS HINGED DOOR KEYED DOOR LATCH ENCLOSURE TYPE NEMA-3R <br /> No. Date Revision <br /> BRANCH DEVICES ❑ FUSED 0 CIRCUIT BREAKER Client: <br /> FINISHED GRADE io ❑ MAIN LUGS ONLY MAIN 200A 0 BREAKER ❑ FUSED SWITCH <br /> II ALL BREAKERS MUST BE RATED TO INTERRUPT A SHORT CIRCUIT CURRENT OF MINIMUM 42,000 AMPS SYMMETRICAL. <br /> #2 AWG TINNED SOLID a ACCEPTABLE MANUFACTURER/MODEL: INTERSECT MODEL: D300L verizonv/ <br /> BARE COPPER WIRE TO NOTES: <br /> GROUND RING 3/4"x10' GROUND ROD PANEL PP-1 IS INCORPORATED INTO THE INTEGRATED LOAD CENTER (ILC). <br /> ALL BREAKER POSITIONS TO BE POPULATED AS SHOWN ABOVE INCLUSIVE CIRCUIT BREAKERS INTENDED FOR OPTIONAL EQUIPMENT. ALL UNUSED BREAKERS TO BE LABELED "SPARE" <br /> (**) CIRCUITS ROUTED INSIDE SAME CONDUIT Implementation Team: <br /> SCALE: NOT TO SCALE 06"SCALE: NOT TO SCALE <br /> 11"X17" SCALE: NOT TO SCALE TYPICAL FENCE GROUNDING DETAIL 4 11"x17"SCALE: NOT TO SCALE PANEL SCHEDULE 3 a CROWN <br /> DRILL WAVE GUI4ROD <br /> TING IF LED SECURITY LIGHT (UTHONIA CAT CASTLE <br /> REQUIRED TO ALLOLLATION LED SECURITY LIGHT #HFEQULEDENT) (TYR) <br /> OF STAINLESS STEEL ED ROD #HFL1-LED-P1- 40K-WFL-MVOLT OR EQUIVALEN77 (TYP) <br /> 1505 WESTLAKE AVE N.SUITE 800 <br /> 7 <br /> OR EQUIVALENT (TYR) SEATTLE,WA 98109 <br /> WAVE GRATING <br /> FENDER WASHER TYR METE A&E Team: <br /> EXOTHERMIC WELD 1/4" ST STEEL GALV PIPE CAP BREAKERACOMIN BpCUIT . <br /> THREADED ROD EP i <br /> L EACH TOWARD <br /> FINISHED GRADE END OF GROU PLATE) EQUIPMENT PAD n <br /> U <br /> ao MORRISON HERSHFIELD <br /> w <br /> WAVE GUIDE POST ELEVATION , 600 STEWART ST,SUITE 200 <br /> BONDING CONDUCTOR ,� 3" DIA STD GALV <br /> TO EQUIPMENT PAD Z d PIPE; PROVIDE SEATTLE,WA 98101 <br /> ANTENNA CABLEw w <br /> GROUND RING w� 3/16"THK CAP Tel:206.268.7370 <br /> GROUNDING CABLEPL SEAL WELD GENERATOR PLUG www.morrisonhershfield.com <br /> ALL AROUND <br /> 24"x24" 4 TO 6 HOUR Project Info: <br /> WAVE GOUNTED 4 TO 6 HOUR PULL BOX (ILC) CRANK TIMER IN O COPPER GROUR PLATE WEATHERPROOFCRANK TIMER N INTEGRATED 0 WATERPROOF CASEBU# 825709 <br /> ENCLOSURE LOAD CENTER 2" CONDUIT ROUTED <br /> WAVE GUIDE POST NUT ANDWASHER MASONIC CENTER <br /> COMBINATION (TYPICAL) UNDERGROUND TO <br /> SECTION A-A METER (TYR) 220 OLYMPIC BLVD. <br /> CONDUIT(S) ROUTED 2" CONDUIT ROUTED EVERETT, WA 98203 <br /> A 47 NOTE: SEE SHEET C-3 FOR CONSTRUCTION UNDERGROUND TO #4 GEC UNDERGROUND TO <br /> SPECIFICATIONS FOR WAVEGUIDE SUPPORT #2 AWG TINNED EQUIPMENT (TYP) ILC (TYR) Drawing Title: <br /> CONDUCTOR TO <br /> ANTENNA CABLE GROUND RING #2 AWG <br /> FULL THREADED ROD ���� JA <br /> (ACTUAL NUMBER TOP OF SLAB (TYP) CONDUCTOR TO CONDUCTOR TO ELECTRICAL, <br /> AS REQUIRED) GROUND RING (TYP) GROUND RING (TYP) <br /> CABLE SUPPORT T.O. FINISHED GRADE T.O. FINISHED GRADE GROUNDING DETAILS & <br /> PANEL SCHEDULE <br /> Tr <br /> WAVE GUIDE MOUNTED GROUND BAR PLATE. <br /> SUSPEND BELOW LOWEST GROUNDING CABLE I - - <br /> ROW OF ANTENNA - - Project Number: Start Date: <br /> CABLES. LOCATE WITHIN (TYP EACH 1800386 03 22 18 <br /> 2'-0" OF CLOSEST ICE ANTENNA CABLE) - II - <br /> BRIDGING POST TO _ L1 _ _ Drafter: Designer: <br /> ANTENNA CABLE COVER #2 AWG BARE TINNED SOLID - - - RR LB <br /> _TS <br /> ASSEMBLY COPPER PIGTAIL ROUTE PIGTAIL <br /> SUCH AS TO AVOID 90' BENDS (2) 4" CONDUITS FROM NEW #2 AWG SOLID TINNED 3" CONDUIT FROM 7NEW #2 AWG SOLID TINNED Project Manager: Professional of Record: <br /> BETWEEN GROUND BAR PLATE EXISTING HANDHOLE/PULLBOX COPPER GROUND RING UTILITY TRANSFORMER COPPER GROUND RING <br /> AND WAVE GUIDE POST RKL RL <br /> 2" CONDUIT TO RADIO CABINET Revision No: Sheet No: <br /> 0 E-5 <br /> WAVEGUIDE MOUNTED GROUND BAR PLATE INSTALLATION 121 ELECTRICAL EQUIPMENT ELEVATION 1 <br />