Laserfiche WebLink
DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL <br /> DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR <br /> OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK <br /> SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN <br /> APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE <br /> SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND <br /> SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON <br /> FINISH GRADE HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD <br /> x NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION <br /> < TOP OF GRAVEL REVIEW OF THIS PROJECT. <br /> 30" DEEP INSPECTION <br /> WELL OR EQUIVALENT <br /> co <br /> TYPE TA TYPE VN TYPE NC TYPE SS ? _ —III_ —IIIIII—III y WAS', O <br /> III III III o0 000 00o III III III MAIN CONDUCTOR, ALDWELD TYPE "GT" Q / <br /> O o III—�o 0000 0 —III—III- COPPER CABLE !1 <br /> - III o00 0°0° o 0o III— 3/4"CRUSHED STONE OR CADWELD TYPE "TA" <br /> 0 <br /> 10 °Oo o°po °O EQUAL FILL TEST WELL TO f` <br /> w o00 °°oo °oo WITHIN 8" OF TOP I V: <br /> m <br /> TYPE W TYPE VS TYPE VB TYPE PT o00 0 000° #2 SOLID TINNED <br /> tO oo°o°oOo 0o COPPER CONDUCTOR 3/4"x10' COPPER CLAD <br /> 5�4 <br /> °o°o°o STEEL GROUND ROD Q <br /> EXOTHERMIC WELDED <br /> CONNECTION (TYPE—GT) <br /> NPE GT NPE GY NPE GR TYPE GL #2 AWG SOLID TINNED BARE <br /> COPPER WIRE EXOTHERMIC WELD <br /> CONNECTION TO GROUND ROD ' <br /> 3/4"x1O' COPPER CLAD <br /> GROUND ROD CADWELD CONSTRUCTION <br /> CONNECTION (TYPE—PT) <br /> SCALE: NOT TO SCALE <br /> SCALE: NOT TO SCALE <br /> 11�X17" SCALE: NOT TO SALE CADWELD GRND CONNECTION DETAIL 9 11"x17" SCALE: NOT TO SCALE GRND ROD WITH ACCESS AREA 8 11 SCALE: NOT TO SCALE °x117" SALE: NOT TO SALE GROUND RING BOND 7 <br /> 0 06/14/18 FINAL CONSTRUCTION <br /> TO ANTENNAS <br /> X (TYPICALLY) A 03/22/18 ISSUED FOR REVIEW <br /> NEW COAXIAL GROUND KITS W/ LONG BARREL 12"TO 24" No. Date Revision <br /> COMPRESSION DOUBLE LUGS, ATTACH TO GROUND BAR & <br /> NOTE: COAT ALL MECHANICAL CONNECTIONS INSTALL BY ANTENNA CONTRACTOR (CADWELD TYPE—GL) RX2 TX1/RX1 N o 120" MAX. <br /> WITH "NOOX" OR APPROVED EQUAL Client: <br /> NEW 4"x24"x1/4"THK COPPER GROUND <br /> BAR, INSTALLED BY GENERAL CONTRACTOR COAX JUMPER (TYP.) <br /> O O WEATHERPROOFING ANTENNA ABLE ABLE CONNECTOR � <br /> KIT (TYPGROUND <br /> WEATHERPROOFING verizon <br /> CONNECTOR GROUND KIT (TYP.) KIT (SEE NOTE 3) #8 AWG STRANDED COPPER <br /> 7WEATHERPROOFING GROUND WIRE (GROUNDED TO <br /> v/ <br /> 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 KIT (TYP.) SEE NOTE 2 #6 AWG ABLE GROUND KIT GROUND BAR). SEE NOTE 1 & 2 <br /> 0 000 <br /> 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O ANTENNA ABLE TO ISOLATE FROM TOWER <br /> BTS EQUIPMENT (TYP.) HALO W/ #2 TO LOWER <br /> 00 0 0 0 0 0 0 0 0 0 0 0 00 TOWER BUS BAR Implementation Team: <br /> COPPER ANTENNA GROUND <br /> BAR, WITH INSULATORS. NOTES: _ of CROWN <br /> O O 1. DO NOT INSTALL ABLE GROUND KIT AT A BEND AND v <br /> TO GROUND RING ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. `�CASTLE <br /> EXOTHERMIC NOTES: 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS <br /> WELD (TYP.) DO NOT INSTALL ABLE GROUND KIT AT A BEND AND ALWAYS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. <br /> #2 AWG SOLID BARE TINNED DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 1606 W A SEATTLE <br /> COPPER GROUND WIRE 3. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT, EATTLE,WAA 98109 <br /> SUITE 800 <br /> WEATHER PROOFING SHALL BE TWO—PART TAPE KIT. COLD COLD SHRINK SHALL NOT BE USED. <br /> SHRINK SHALL NOT BE USED. A&E Team: <br /> SCALE: NOT TO SCALE SCALE: NOT TO SCALE F <br /> 11"07" SCALE: NOT TO SALE GROUND BAR DETAIL 6 %17"SALE: NOT TO SALE GRND CABLE CONNECTION 5 11"x17" SCALE: NOT TO SCALE COAX CABLE GROUNDING 4 MORRISON HERSHFIELD <br /> 600 STEWART ST,SUITE 200 <br /> SEATTLE,WA 98101 <br /> Tel:206.268.7370 <br /> www.morrison h emhfield.com <br /> FINISHED GRADE, OR GROUND TRENCH Project Info: <br /> COVER MATCH SLOPE AND AUTIONARY TAPE <br /> THICKNESS OF EXISTING <br /> M PACTED SATSFACTORYFI LL <br /> W/ NATIVE GRADE BU# 825709 <br /> OR IMPORTED SOIL MASONIC CENTER <br /> 220 OLYMPIC BLVD. <br /> 114w EVERETT, WA 98203 <br /> nZ Drawing Title: <br /> TELEPHONE CONDUITS w <br /> N EXOTHERMIC WELD <br /> COMPACTED SAND ELECTRICAL & <br /> ELECTRICAL CONDUITS <br /> COMPACTED SAND BED RING GROUND 2 AWG GROUNDING <br /> BCW SOLID, TINNED DETAILS <br /> GROUND ROD COPPER <br /> —II CLAD STEEL ROD WITH <br /> iv NOTES: MINIMUM 3/4"x1O'-0" <br /> 3" MIN. 1. GROUND LINE TO BE A MIN. OF Project Number: Start Date: <br /> 6" MIN. TYP 30"OR BELOW FROST LINE, 1800386 03 22 1 8 <br /> TYP WHICHEVER IS DEEPER. <br /> 2. GROUND ROD SHALL BE DRIVEN r Drafter: Designer: <br /> VERTICALLY, NOT TO EXCEED 45 RR LB <br /> DEGREES FROM THE VERTICAL. <br /> Project Manager: Professional of Record: <br /> RKL RL <br /> Revision No: Sheet No: <br /> 0 E-7 <br /> II"x17-SCALE: NOT TO SALE NOT USED 3 11"x 17" SCALE: NOT TO SCALE POWER/T E L C O TRENCH 121 11"x37" SCALE: NOT TO SALE GROUND ROD 1 <br />