GENERAL NOTES LINE/ANTENNA NOTES ABBREVIATIONS DI NOT SCALEDRAWINGS.CONTRACTOR MUST VERIFY ALL <br /> DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR <br /> OMISSIONS.NO VARIATIONS MODIFICATIONS TO WORK <br /> SHOWN SHALL BE IMPLEMENTED <br /> D WITHOUT PRIOR WRITTEN <br /> APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE <br /> 1. WORK SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. ALL NECESSARY LICENSES, 1. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLES SHALL CONFORM TO ASTM A307 OR AGL ABOVE GROUND LEVEL GA GAUGE PLYWD PLYWOOD SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND <br /> CERTIFICATES, ETC., REQUIRED BY AUTHORITY HAVING JURISDICTION SHALL BE PROCURED AND PAID FOR BY THE ASTM A36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO F3125 Gr. A325. A/C AIR CONDITIONING GALV GALVANIZED PT PRESSURE TREATED SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON <br /> CONTRACTOR. FASTENERS SHALL BE 5/8" MIN. DIA. BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED FROM THE PLANE. ALL APPROX APPROXIMATELY GC GENERAL CONTRACTOR PROJ PROJECT HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD <br /> EXPOSED FASTENERS, NUTS, AND WASHERS SHALL BE GALVANIZED OTHERWISE NOTED. CONCRETE EXPANSION AZ AZIMUTH GRND GROUND PROP PROPERTY NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION <br /> 2. MORRISON HERSHFIELD CORPORATION HAS NOT CONDUCTED, NOR DOES IT INTEND TO CONDUCT ANY INVESTIGATION ANCHORS SHALL BE HILTI KWIK BOLTS UNLESS OTHER WISED NOTED. ALL ANCHORS INTO CONCRETE SHALL BE GYP BD GYPSUM WALL BOARD (P) PROPOSED REVIEW OF THIS PROJECT. <br /> AS TO THE PRESENCE OF HAZARDOUS MATERIAL, INCLUDING, BUT NOT LIMITED TO, ASBESTOS WITHIN THE CONFINES STAINLESS STEEL. BLDG BUILDING <br /> OF THIS PROJECT. MORRISON HERSHFIELD CORPORATION DOES NOT ACCEPT RESPONSIBILITY FOR THE BLK BLOCKING HT HEIGHT QTY QUANTITY <br /> INDEMNIFICATION, THE REMOVAL, OR ANY EFFECTS FROM THE PRESENCE OF THESE MATERIALS. IF EVIDENCE OF 2. THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. CONNECTION HVAC HEATING VENTILATION AIR <br /> HAZARDOUS MATERIALS IS FOUND, WORK IS TO BE SUSPENDED AND THE OWNER NOTIFIED. THE CONTRACTOR IS NOT HARDWARE SHALL BE STAINLESS STEEL. CLG CEILING CONDITIONING REQ REQUIRED ��E TO PROCEED WITH FURTHER WORK UNTIL INSTRUCTED BY THE OWNER IN WRITING. CL CENTERLINE HORZ HORIZONTAL RM ROOM <br /> 3. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY NORTH AND NOTIFY CLR CLEAR FIR HOUR RO ROUGH OPENING 0 <br /> 3. ALL MATERIAL FURNISHED UNDER THIS CONTRACT SHALL BE NEW, UNLESS OTHERWISE NOTED. ALL WORK SHALL BE CONSULTANT OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. CONC CONCRETE ROW RIGHT OF WAY NV GUARANTEED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. THE CONTRACTOR SHALL REPAIR OR REPLACE AT CONST CONSTRUCTION IN INCH OF `V r�1� <br /> HIS EXPENSE ALL WORK THAT MAY DEVELOP DEFECTS IN MATERIALS OR WORKMANSHIP WITHIN SAID PERIOD OF TIME 4. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS. USE STAINLESS STEEL CONT CONTINUOUS INFO INFORMATION SILT SHEET ^ <br /> OR FOR ONE YEAR AFTER THE FINAL ACCEPTANCE OF THE ENTIRE PROJECT, WHICHEVER IS GREATER. HARDWARE THROUGHOUT. ID INSIDE DIAMETER SIM SIMILAR <br /> DET DETAIL INSUL INSULATION SPEC SPECIFICATION j <br /> 4. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING 5. THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS. DIA DIAMETER INT INTERIOR SF SQUARE FOOT <br /> CONDITIONS AND UTILITIES AT THE JOB SITE BEFORE WORK IS STARTED. NO CLAIMS FOR EXTRA COMPENSATION FOR DIAG DIAGONAL IBC INTERNATIONAL BUILDING CODE SS STAINLESS STEEL <br /> WORK WHICH COULD HAVE BEEN FORESEEN BY AN INSPECTION, WHETHER SHOWN ON THE CONTRACT DOCUMENTS OR 6. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS TO BE A DIM DIMENSION STL STEEL <br /> NOT, WILL BE ACCEPTED OR PAID. MIN. OF 8" RADIUS DBL DOUBLE LES POUNDS STRUCT STRUCTURAL <br /> DN DOWN STD STUD <br /> 5. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS AND 7. FOR GROUNDING TO BUILDING FRAME & HATCH PLATE GROUND BARS. USE A TWO-BOLT HOLE NEMA DRILLED DWG DRAWING MGR MANAGER SUS SUSPENDED <br /> CONDITIONS AT THE JOB SITE WHICH COULD AFFECT THE WORK UNDER THIS CONTRACT. ALL MANUFACTURERS CONNECTOR SUCH AS T&B 32007 OR APPROVED EQUAL MFR MANUFACTURER p a�Z 7 <br /> RECOMMENDED SPECIFICATIONS, EXCEPT THOSE SPECIFICATIONS HEREIN, WHERE MOST STRINGENT SHALL BE COMPLIED EA EACH MAX MAXIMUM THRU THROUGH ��, �� W <br /> WITH. 8. FOR ALL EXTERNAL GROUND CONNECTIONS, CLAMPS & CADWELDS, APPLY A LIBERAL PROTECTIVE COATING OR AN ELEC ELECTRICAL MECH MECHANICAL TNNG TINNED <br /> ANTI-OXIDE COMPOUND <br /> 6 MECHANCAL,THE CELECTRICAL,TOR SHALLPLU BING, CIVIL, 0RRIFY AND AARCHTECTURAL WORK.SIZE AND N OF ALL OPENINGS FOR STRUCTURAL, EQ EQUAL g REPAIRALL GALVAGALVANIZED SURFACES THAT OHAVE ABEE O <br /> N DAMAGED BY CHEMICAL BYTHERMO-WELDING. USE ERICO T-319 GALVANIZING EQUIP EQUIPME P TYPICAL EQUIPMENT MSC MSCELLANEOUS G UNDERGROUND ONAL E�G` <br /> BAR/COLD GALVANIZING PAINT. (E) EXISTING LIN0 UNLESS NOTED OTHERWISE <br /> 7. THE CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST BETWEEN THE LOCATIONS OF ANY AND ALL MECHANICAL, EXT EXTERIOR <br /> ELECTRICAL, PLUMBING, OR STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND 10.SEAL ALL CONDUIT PENETRATIONS INTO MODULAR BUILDING WITH A SILICONE SEALANT AND ALL CONDUIT OPENINGS. N/A NOT APPLICABLE VIE VERIFY IN FIELD <br /> MAINTENANCE ARE MET. NOTIFY THE CONSULTANT OF ANY CONFLICTS. THE CONSULTANT HAS THE RIGHT TO MAKE FIN FINISH NIC NOT IN CONTRACT VERT VERTICAL <br /> MINOR MODIFICATIONS IN THE DESIGN OF THE CONTRACT WITHOUT THE CONTRACTOR GETTING ADDITIONAL 11.ALL COAXIAL CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES NOT TO EXCEED 3' OR FLR FLOOR NTS NOT TO SCALE <br /> COMPENSATION. THE CABLE MANUFACTURES SPECIFICATIONS WHICHEVER IS LESS, WITH HARDWARE SPECIFIED IN THE COAXIAL CABLE FLUOR FLUORESCENT WP WATER PROOF CONSTRUCTION <br /> ROUTING DETAILS OF THE SUPPLIED STRUCTURAL REPORT. FT FOOT OC ON CENTER W/ WITH <br /> 8. DO NOT SCALE THE DRAWINGS. DIMENSIONS ARE EITHER TO THE FACE OF FINISHED ELEMENTS OR TO THE CENTER OD OUTSIDE DIAMETER W/O WITHOUT <br /> LINE OF ELEMENTS, UNLESS NOTED OTHERWISE. CRITICAL DIMENSIONS SHALL BE VERIFIED AND NOTIFY THE 12.THE COAXIAL ANTENNA CABLE INSTALLER SHALL BE RESPONSIBLE FOR PERFORMING AND SUPPLYING THREE (3) <br /> CONSULTANT OF ANY DISCREPANCIES. TYPEWRITTEN SWEEP TESTS (ANTENNA RETURN LOSS TEST). THIS TEST SHALL BE PERFORMED TO THE SPECIFICATIONS <br /> AND PARAMETERS OUTLINED BY THE VERIZON WIRELESS RADIO FREQUENCY THRU ENGINEER. THIS TEST SHALL BE <br /> 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY CLEAN UP OF ALL TRADES AND REMOVE ALL DEBRIS FROM PERFORMED PRIOR TO FINAL ACCEPTANCE OF THE SITE. (1) COPY TO BE PLACED IN SHELTER. LOP UG POWER CONDUIT UGT UG TELCO CONDUIT <br /> THE CONSTRUCTION SITE. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL THOROUGHLY CLEAN THE <br /> BUILDING, SITE, AND ANY OTHER SURROUNDING AREAS TO A BETTER THAN EXISTING CONDITION. 13.THE COAXIAL ANTENNA CABLE INSTALLER SHALL BE RESPONSIBLE FOR PERFORMING AND SUPPLYING VERIZON <br /> WIRELESS WITH THREE TYPE WRITTEN TIME DOMAIN REFLECTOMETER TESTS TO VERIFY CABLE LENGTH AND TO CHECK <br /> 10. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION FOR WATER DAMAGE. <br /> AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC. ACCORDING TO APPLICABLE CODES, STANDARDS, AND GOOD <br /> CONSTRUCTION PRACTICES. 14.VAPOR WRAP WILL BE USED TO SEAL ALL CONNECTIONS. 0 06/14/18 FINAL CONSTRUCTION <br /> 11. THE CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS. 15.ALL JUMPERS TO THE ANTENNAS FROM THE MAIN TRANSMISSION LINE WILL BE 1/2" DIA, AND SHALL NOT EXCEED A 03/22/18 ISSUED FOR REVIEW <br /> 6'-0" <br /> 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EXISTING CONSTRUCTION AND REPAIR ALL <br /> DAMAGES TO BETTER THAN NEW CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DAMAGE TO 16.ALL MAIN TRANSMISSION CABLE WILL BE TERMINATED AT A VERIZON WIRELESS POLYPHASER PROTECTOR LOCATED No. Date I Revision <br /> THE BUILDING SITE OR ANY ADJACENT STRUCTURES AROUND THE PROJECT. THE CONSULTANT SHALL BE SOLE AND WITHIN 1'-0" OF THE EQUIPMENT SHELTER. Client: <br /> FINAL JUDGE AS TO THE QUALITY OF THE REPAIRED CONSTRUCTION. ANY ADDITIONAL MODIFICATIONS WHICH MUST BE <br /> MADE SHALL BE MADE AT THE CONTRACTOR'S EXPENSE. 17.ANTENNA CABLE LENGTHS HAVE BEEN DETERMINED BASED ON THESE PLANS, CABLE LENGTHS LISTED ARE <br /> APPROXIMATED AND ARE NOT INTENDED TO BE USED FOR FABRICATION DUE TO FIELD CONDITIONS ACTUAL CABLE <br /> 13. WHERE ONE DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS, EVEN LENGTHS REQUIRE. CONTRACTOR MUST FIELD VERIFY ANTENNA CABLE LENGTHS PRIOR TO ORDER. <br /> THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS OR REFERRED TO IN THE SPECIFICATIONS, UNLESS NOTED <br /> OTHERWISE. 18.ALL MAIN CABLES WILL BE COLOR CODED AT FOUR LOCATIONS: A) AT ANTENNA PRIOR TO JUMPER, AT THE ver izo nV <br /> BOTTOM OF THE TOWER, C) EXTERIOR PART OF THE WAVE GUIDE ENTRY PORT (AT THE SHELTER/CABINET WALL), D) <br /> 14. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH INTERIOR OF THE SHELTER/CABINET. <br /> THE EXISTING PITCH, GRADE, AND ELEVATION SO THE ENTIRE STRUCTURE SHALL HAVE A SMOOTH TRANSITION. <br /> 19.ALL MAIN CABLES WILL BE GROUNDED AT: A) AT THE ANTENNA MOUNTING PIPE, B) MIDDLE OF THE CABLE RUN IF <br /> 15. THE CONTRACTOR SHALL MODIFY THE EXISTING FLOORS, WALL, CEILING, OR OTHER CONSTRUCTION AS REQUIRED TO OVER 200 C) PRIOR TO ENTERING EQUIPMENT SHELTER/CABINET (WITHIN 1' OF ENTRY). <br /> GAIN ACCESS TO AREAS FOR ALL MECHANICAL, PLUMBING, ELECTRICAL, OR STRUCTURAL MODIFICATIONS. WHERE THE <br /> EXISTING CONSTRUCTION DOORS, PARTITIONS, CEILING, ETC., ARE TO BE REMOVED, MODIFIED, OR REARRANGED OR 20.PROVIDE AT LEAST 6" OF SLACK IN THE MAIN COAXIAL CABLES AT THE TOWER TOP TO PROVIDE FOR FUTURE Implementation Team: <br /> WHERE THE EXPOSED OR HIDDEN MECHANICAL, ELECTRICAL, SYSTEMS ARE ADDED OR MODIFIED, THE GENERAL CONNECTOR REPLACEMENT. <br /> CONTRACTOR SHALL REPAIR, PATCH AND MATCH ALL EXISTING CONSTRUCTION AND FINISHES OF ALL FLOORS WALLS <br /> AND CEILINGS. WHERE CONCRETE MASONRY CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL TOOTH IN ALL NEW 21.PROVIDE A CABLE DRIP LOOP AT THE BOTTOM OF THE TOWER BELOW THE TOWER BOTTOM GROUND CONNECTIONS a <br /> CONSTRUCTION TO MATCH THE EXISTING BOND. WHERE CONCRETE CONSTRUCTION IS MODIFIED, THE CONTRACTOR AND AS THE CABLE TRANSITIONS TO THE SHELTER/CABINET. CROWN <br /> SHALL VERIFY THE EXACT DETAILS TO BE USED FOR CONSTRUCTION. ALL WORK SHALL BE COVERED UNDER THE <br /> GENERAL CONTRACT. 22.ANTENNAS AND COAX TO BE PROVIDED BY VERIZON WIRELESS, CONTRACTOR TO COORDINATE DELIVERY. `�CASTL E <br /> 16. VERIFY ALL EXISTING DIMENSIONS PRIOR TO PERFORMING WORK. <br /> PROJECT INFORMATION 1606 WEEA N.SUITE 800 <br /> SATTL <br /> 17. VERIFY LOCATION OF ALL BURIED UTILITIES PRIOR TO ANY EXCAVATION. ATTLE,WAA 98109 <br /> 18. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING FOR COMMERCIAL POWER IMMEDIATELY UPON <br /> AWARD OF CONTRACT. THE GENERAL CONTRACTOR IS REQUIRED TO KEEP ALL DOCUMENTATION RECEIVED FROM THE 1. THIS IS AN UNMANNED FACILITY AND RESTRICTED ACCESS EQUIPMENT AND WILL BE USED FOR THE TRANSMISSION OF A&E Team: <br /> POWER COMPANY, ACKNOWLEDGING APPLICATION FOR POWER, WRITTEN AND VERBAL DISCUSSIONS WITH THE POWER RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. <br /> COMPANY, ETC. <br /> 19. THE GENERAL CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION OF THE EXPECTED DATE OF COMPLETION OF THE 2• VERIZON WIRELESS CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACILITY WILL BE SERVICED ONLY BY VERIZON n <br /> POWER CONNECTION FROM THE POWER COMPANY. WIRELESS EMPLOYEE SERVICE PERSONNEL FOR REPAIR PURPOSES ONLY. THIS FACILITY IS UNOCCUPIED AND NOT <br /> DESIGNED FOR HUMAN OCCUPANCY THUS IT IS NOT OPEN TO THE PUBLIC. MORRISON HERSHFIELO <br /> 20. IF THE POWER COMPANY IS UNABLE TO PROVIDE THE POWER CONNECTION BY OWNER'S REQUIRED DATE, THE 3. THIS FACILITY WILL CONSUME NO UNRECOVERABLE ENERGY. 600 STEWART ST,SUITE 200 <br /> GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN A TEMPORARY GENERATOR UNTIL THE POWER COMPANY SEATTLE,WA 98101 <br /> CONNECTION IS COMPLETED. COSTS ASSOCIATED WITH THE TEMPORARY GENERATOR TO BE APPROVED BY THE OWNER. 4. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. Tel:206.268.7370 <br /> 21. IF THE GENERAL CONTRACTOR FAILS TO TAKE NECESSARY MEASURES AS DESCRIBED IN NOTES 18, 19 AND 20 5. NO WASTE WATER WILL BE GENERATED AT THIS LOCATION. <br /> IMPORTANT NOTICE www.morrisonhemnfield.com <br /> ABOVE, THE GENERAL CONTRACTOR SHALL PROVIDE A TEMPORARY GENERATOR AT NO COST TO THE OWNER. <br /> 22. PLANS PART OF THIS SET ARE COMPLEMENTARY. INFORMATION IS NOT LIMITED TO ONE PLAN. DRAWINGS AND <br /> 6. NO SOLID WASTE WILL BE GENERATED AT THIS LOCATION. Project Info: <br /> SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT, WHETHER THE �� MAINTENANCE CREW (TYPICALLY ONE PERSON) WILL MAKE AN AVERAGE OF ONE TRIP PER MONTH THE EXISTING CONDITIONS REPRESENTED HEREIN ARE BASED ON VISUAL OBSERVATIONS AND INFORMATION PROVIDED BY <br /> PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER VAREI OTHERS. MORRISON HERSHFIELD CORPORATION CANNOT GUARANTEE THE CORRECTNESS NOR COMPLETENESS OF THE B U# 825709 <br /> PROJECTS OR EXTENSION TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE AT ONE HOUR PER VISIT. EXISTING CONDITIONS SHOWN AND ASSUMES NO RESPONSIBILITY THEREOF. CONTRACTOR AND HIS SUB-CONTRACTORS <br /> COMPENSATION TO THE ARCHITECT. THESE PLANS WERE PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AS REQUIRED FOR PROPER EXECUTION OF PROJECT. REPORT MASONIC CENTER <br /> AUTHORITIES FOR REVIEW FOR COMPLIANCE WITH APPLICABLE CODES AND IT IS THE SOLE RESPONSIBILITY OF THE ANY CONFLICTS OR DISCREPANCIES TO THE CONSULTANT PRIOR TO CONSTRUCTION. 220 OLYMPIC BLVD. <br /> OWNER AND/OR CONTRACTOR TO BUILD ACCORDING TO APPLICABLE BUILDING CODES. EVERETT, WA 98203 <br /> 23. IF CONTRACTOR OR SUB-CONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS, THEN IT IS Drawing Title: <br /> THE CONTRACTOR'S AND THE SUB-CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE ARCHITECT WITH 4 COPIES OF <br /> THE PROPOSED CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH THE WORK. IN ADDITION THE CONTRACTOR LEGEND <br /> AND SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY APPROVALS FROM THE BUILDING <br /> AUTHORITIES FOR THE PROPOSED CHANGES BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR AND <br /> SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM BUILDING/WALL/DETAIL SECTION LARGE SCALE DETAIL GENERAL <br /> �G I <br /> BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK. E N E RAL NOTES <br /> 24. IN EVERY EVENT, THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL BE INTERPRETED TO BE A MINIMUM DETAIL NUMBER A N D SYMBOLS <br /> ACCEPTABLE MEANS OF CONSTRUCTION BUT THIS SHALL NOT RELIEVE THE CONTRACTOR, SUB-CONTRACTOR, AND/OR 1 1 DETAIL NUMBER <br /> SUPPLIER/MANUFACTURER FROM PROVIDING A COMPLETE AND CORRECT JOB WHEN ADDITIONAL ITEMS ARE REQUIRED <br /> TO THE MINIMUM SPECIFICATION. IF ANY ITEMS NEED TO EXCEED THESE MINIMUM SPECIFICATIONS TO PROVIDE A A_1 <br /> COMPLETE, ADEQUATE AND SAFE WORKING CONDITION, THEN IT SHALL BE THE DEEMED AND UNDERSTOOD TO BE SHEET NUMBER <br /> INCLUDED IN THE DRAWINGS. FOR EXAMPLE, IF AN ITEM AND/OR PIECE OF EQUIPMENT REQUIRES A LARGER WIRE WHERE DETAILED SHEET NUMBER Project Number: Start Date: <br /> SIZE (I.E. ELECTRICAL WIRE), STRONGER OR LARGER PIPING, INCREASED QUANTITY (I.E. STRUCTURAL ELEMENTS), WHERE DETAILED <br /> REDUCED SPACING, AND/OR INCREASED LENGTH (I.E. BOLT LENGTHS, BAR LENGTHS) THEN IT SHALL BE DEEMED AND 1800386 03/22/18 <br /> UNDERSTOOD TO BE INCLUDED IN THE BID/PROPOSAL. THESE DOCUMENTS ARE MEANT AS A GUIDE AND ALL ITEMS Drafter: Designer: <br /> INFERRED SHALL BE DEEMED TO BE INCLUDED. REFERENCE ELEVATION DETAIL BUG <br /> RR LB <br /> 25. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS SHALL NOT BE CONSTRUED TO CREATE A CONTRACTUAL DETAIL NUMBER <br /> RELATIONSHIP OF ANY KIND BETWEEN THE ARCHITECT AND THE CONTRACTOR. 1 Project Manager: Professional of Record: <br /> 26. CONTRACTOR & ANY SUBCONTRACTORS TO MAINTAIN KEEPING THE ROAD ACCESS GATE LOCKED AT ALL TIMES. q-1 q_p RKL RL <br /> 27. IN RAW LAND CONDITIONS, TOWER FOUNDATION STRUCTURAL STEEL TO BE GROUNDED PRIOR TO CONCRETE POUR. REFERENCED SHEET NUMBER Revision No: Sheet No: <br /> TOWER FOUNDATION STRUCTURAL STEEL TO BE CONNECTED TO PERMANENT GROUND ROD PRIOR TO TOWER ERECTION. DRAWING WHERE DETAILED <br /> TOWER GROUND MUST BE MAINTAINED AT ALL TIMES. 0 <br /> T_2 <br />