Laserfiche WebLink
DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL <br /> DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR <br /> OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK <br /> PROPOSED ANTENNA AND COAX SCHEDULE SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN <br /> DIM 3 APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE <br /> DIM 2 <br /> DIM 2 <br /> NUMBER OF ELEC MECH NUMBER OF FEEDER FEEDER ADDITIONAL DRAWINGS NAL SUPERSEDED BY THE LATEST REVISION.ALL DRAWS AND <br /> SECTOR ALPHA AZIMUTH RAD CENTER VENDOR MODEL SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON <br /> ANTENNAS TILT DOWN iLT FEEDERS TYPE LENGTH EQUIPMENT HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD <br /> NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION <br /> AWS 0' 59'-0" 1 COMMSCOPE NHH-65A—R2B — — (4) COAX t75'-0" (1) TWIN DIPLEXER REVIEW OF THIS PROJECT. <br /> N <br /> LTE 0' 54'-0" 1 COMMSCOPE NHH-65A—R28 — — (4) COAX f75'—O" (1) TWIN DIPLEXER <br /> a NUMBER OF ELEC MECH NUMBER OF FEEDER FEEDER ADDITIONAL <br /> SECTOR BETA AZIMUTH RAD CENTER VENDOR MODEL C E CU <br /> ANTENNAS DOWNTILT FEEDERS TYPE LENGTH EQUIPMENT <br /> FRONT BACK SIDE AWS 120' 59'-0" 1 COMMSCOPE NHH-65A—R28 — — (4) COAX t75'-0" (1) TWIN DIPLEXER Y O `VAS,., O <br /> LTE 120' 54'-0" 1 COMMSCOPE NHH-65A—R28 — — (4) COAX t75'-0" (1) TWIN DIPLEXER ^ <br /> QTY DIM 1 DIM 2 DIM 3 WEIGHT NUMBER OF ELEC MECH NUMBER OF FEEDER FEEDER ADDITIONAL <br /> RRU 4449 B13/B5 3 18.0" 13.2" 9.4" 70.0 LBS <br /> SECTOR GAMMA AZIMUTH RAD CENTER ANTENNAS VENDOR MODEL ELEC <br /> DOWNTILT FEEDERS TYPE LENGTH EQUIPMENT <br /> I <br /> RRU 8843 B2/1366A 3 18.0" 13.2" 11.3" 75.0 LBS AWS 240' 59'-0" 1 COMMSCOPE NHH-65A-R28 - - (4) COAX f75'-O" (1) TWIN DIPLEXER <br /> LTE 240' 54'-0" 1 COMMSCOPE NHH-65A-R2B - - (4) COAX t75'-0" (1) TWIN DIPLEXER 422 7 <br /> �GISTE <br /> NOTES: <br /> 1. INSTALL UNITS PER MANUFACTURER SPECIFICATIONS ANTENNA MOUNTS SHALL COMPLY WITH NSTD-445 STANDARDS AS REQUIRED BY VERIZON. �` <br /> 'JAL <br /> 24"x36"SCALE: NOT TO SCALE PROPOSED RRU DIMENSIONS 5 is PROPOSED VERIZON WIRELESS <br /> 11"x17"SCALE: NOT TO SCALE a a AWS PANEL ANTENNA <br /> [COMMSCOPE NHH-65A-R2B] CONSTRUCTION <br /> DIM 3 PROPOSED VERIZON WIRELESS <br /> DII DII TWIN DI SECT R] A <br /> [3 TOTAL, 1 PER SECTOR] <br /> EXISTING 76'-0" PROPOSED VERIZON WIRELESS <br /> MONOPOLE TOWER FLUSH MOUNT <br /> QTY DIM 1 DIM 2 DIM 3 WEIGHT PROPOSED VERIZON WIRELESS PROPOSED VERIZON WIRELESS <br /> AWS PANEL ANTENNA AWS PANEL ANTENNA <br /> SECTOR ALPHA [COMMSCOPE NHH-65A—R281 [COMMSCOPE NHH-65A—R2B] 0 06/14/18 FINAL CONSTRUCTION <br /> _ PROPOSED VERIZON WIRELESS <br /> NHH-65A—R2B 2 55.6" 11.9" 7.1" 35A LBS 3Q A 03/22/18 ISSUED FOR REVIEW <br /> J N LTE PANEL ANTENNA <br /> [COMMSCOPE NHH-65A—R2B] <br /> SECTOR BETA GPV,"qQ C B �\ q PROPOSED VETWINND WIRELESS <br /> A No. Date Revision <br /> NHH-65A-R2B 2 55.6" 11.9" 7.1" 35A LBS 72p. [3 TOTAL, 1 PER SECTOR] Client: <br /> EXISTING 76'-0" PROPOSED VERIZON WIRELESS <br /> MONOPOLE TOWER FLUSH MOUNT <br /> SECTOR GAMMA ■ <br /> NHH-65A—R2B 2 55.6" 11.9" 7.1 35A LBS 59'-0" TIP HEIGHT PROPOSED VERIZON WIRELESS PROPOSED VERIZON WIRELESS verizon <br /> LTE PANEL ANTENNA LTE PANEL ANTENNA <br /> [COMMSCOPE NHH-65A—R2B] [COMMSCOPE NHH-65A—R2B] <br /> FRONT BACK SIDE <br /> �pP 9 Implementation Team: <br /> DIM 2 NOTES: C' C B <br /> i� 1. INSTALL ANTENNAS PER MANUFACTURER SPECIFICATIONS <br /> "I 2. CONTRACTOR TO TORQUE ALL MOUNTING HARDWARE CROWN <br /> o PER MANUFACTURER SPECIFICATIONS v CASTLE <br /> TOP 54'-0" TIP HEIGHT <br /> 1505 WESTLAKE AVE N.SUITE 800 <br /> SEATTLE,WA 98109 <br /> 24"x36" SCALE: NOT TO SCALE PROPOSED ANTENNA DIMENSIONS 4 24"x36"SCALE: ,/2•' - ''-°" PROPOSED ANTENNA CONFIGURATION 3 A&E Team: <br /> 11"x17" SCALE: NOT TO SCALE 11"x17"SCALE: 1/4" = 1'-0" 2' 1' 0" 2' 1 <br /> PROPOSED MW SCHEDULE <br /> MORRISON HERSHFIELD <br /> AZIMUTH RAD CENTER QUANTITY VENDOR MODEL SIZE TILT CABLE CABLE QTY CABLE TYPE 600 STEWART ST,SUITE 200 <br /> LENGTH SEATTLE,WA 98101 <br /> Tel:206.268.7370 <br /> 2 CAT5e wWW.morrisonhemhfield.com <br /> 100' 47'-0" 1 RFS SC2-19OBB 2'0 0' X'f <br /> 2 FIBER Project Info:2-1/2" STD GALV ANTENNA MOUNTS SHALL COMPLY WITH NSTD-445 STANDARDS AS REQUIRED BY VERIZON. B Uti-..µµ 8Z57O9 <br /> SCH 40 PIPE MOUNT <br /> MECHANICAL DOWN TILT MW SPECIFICATIONS MASONIC CENTER <br /> KIT (AS REQ'D) BY 220 OLYMPIC BLVD. <br /> 2-1/2" STD CALM ANTENNA MANUFACTURER PROPOSED VERIZON WIRELESS MODEL QTY DIM A DIM B DIM C WEIGHT EVERETT, WA 98203 <br /> SCH 40 PIPE MOUNT UNIVERSAL RING MOUNT <br /> MODEL# LWRM BY SITEPR01 SC2-19OBB 1 26.4"0 11.7" 11.5" 20 LBS <br /> OR APPROVED EQUAL Drawing Title: <br /> ANTENNA MOUNT EXISTING MONOPOLE <br /> BRACKETS BY ANTENNA <br /> MANUFACTURER DIM A <br /> PANEL ANTENNA <br /> PANEL ANTENNA PROPOSED VERIZON WIRELESS ANTENNA <br /> 2'0 MICROWAVE DISH CONFIGURATION <br /> ANTENNA MOUNT <br /> BRACKETS BY ANTENNA <br /> TOP VIEW MANUFACTURER <br /> m <br /> MW Project Number: Start Date: <br /> aZ=1o0• 1800386 03/22/18 <br /> Drafter: Designer: <br /> RR LB <br /> PROPOSED VERIZON WIRELESS 8" <br /> STANDOFF ARM (SITEPRO1 P/N MM01 Project Manager: Professional of Record: <br /> OR APPROVED EQUAL); ORDER RKL RL <br /> 2-1/2" STD GALV PIPE SEPARATELY Revision No: Sheet No: <br /> DIM C <br /> 0 RF- 1 <br /> IL17"SCALE: NOT TO SCALE TYPICAL ANTENNA ATTACHMENT 11"x17"SCALE: NOT TO SCALE PROPOSED MICROWAVE CONFIGURATION 1 <br />