Laserfiche WebLink
SITTS & HILL ENGINEERS, INC. <br /> TACOMA, WASHINGTON (253)474-9449 JOB: 17659 <br /> DESIGNED: EMF DATE: 03/17/2020 12 <br /> PROJECT: SITE PUMPED INDUSTRIAL WASTE CHECKED: BKL DATE: 03/17/2020 <br /> Trench Walls and Base Slabs: <br /> The trench walls were analyzed for the design loads using the software program <br /> Enercalc, and both the trench walls and base slabs were analyzed as retaining walls <br /> using the software program RetainPro. <br /> Enercalc Analysis: I <br /> The trench walls were modeled as cantilever elements in Enercalc.Assuming a 6'-0" <br /> wheel group base and a 1:1 load distribution throughout the depth of the trench, the 2'-0" <br /> tall wall was modeled as a 4'-0" wide element that resists half an axle load. The wheel <br /> loads were applied with eccentricities equal to half the wall thickness. Per the attached <br /> Enercalc analysis, 8" thick walls reinforced with #5 vertical reinforcing bars at 9" O.C. are <br /> OK to withstand the design loads. <br /> RetainPro Analysis: I <br /> The trench walls and base slabs were analyzed as retaining walls using the software <br /> program RetainPro. Soil and loading properties were assigned to the model according to <br /> the values provided in the reference Geotechnical report for the site, attached in <br /> Appendix A. Half an axle load was applied as a linear live load to the top of the 2'-0" <br /> deep retaining wall, and the distributed loads are calculated below assuming a 1:1 load <br /> distribution through the wall to the base of the slab. A surcharge load of 250psf is applied <br /> according to AASHTO LRFD Bridge Design Specifications Table 3.11.6.4-2. <br /> P _ I <br /> wr,L3X2:= 3902 pl 5.33 ft <br /> = f <br /> The 8" thick trench base slab and walls reinforced with #5 bars at 9" O.C. are adequate for the <br /> design loads per the attached RetainPro analyses. The maximum soil bearing pressure was <br /> found to be 3386psf, which is deemed to be acceptable given the short term nature of the <br /> wheel loading. This assumption is also justified by the maximum allowable mat slab design <br /> soil bearing value of 4000psf given in the reference Geotechnical report. <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br />